Real Time Visualization of Femoroacetabular Impingement and Subluxation Using 320-Slice Computed Tomography

被引:47
|
作者
Wassilew, Georgi I. [1 ]
Janz, Viktor [1 ]
Heller, Markus O. [2 ]
Tohtz, Stephan [1 ]
Rogalla, Patrik [3 ]
Hein, Patrick [4 ]
Perka, Carsten [1 ]
机构
[1] Charite, Orthoped Dept, Ctr Musculoskeletal Surg, D-13353 Berlin, Germany
[2] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[3] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
[4] Charite, Dept Radiol, D-13353 Berlin, Germany
关键词
four-dimensional computed tomography; femoroacetabular impingement; dynamic investigations; FEMORAL-HEAD; ADULT HIP; OSTEOARTHRITIS; RETROVERSION; ACETABULUM; RISK; CT;
D O I
10.1002/jor.22224
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We visualized extreme ranges of motion of the hip and located femoroacetabular impingement (FAI) and subluxations using 4dimensional (D) volume computed tomography (CT). In dynamic 4D CT, 30 patients with hip pain (>3 months) and positive clinical and radiological signs of impingement were prospectively analyzed. The investigations were performed in flexion, abduction, and external rotation. The accuracy of the CT visualization of FAI was compared with the intraoperative findings during surgical dislocation, which served as the gold standard. Compared to the intraoperative visualization of FAI, the dynamic CT images showed a high degree of accuracy. 4D CT is a suitable method to dynamically visualize the functional consequences of anatomical FAI pathologies. The location of impingement can be accurately determined, and when combined with information about possible labral tears and chondral damage supplied by magnetic resonance arthrography, allows the surgeon to select the optimal surgical access and plan the required operation for minimal invasiveness. (C) 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:275-281, 2013
引用
收藏
页码:275 / 281
页数:7
相关论文
共 50 条
  • [1] 320-Slice Computed Tomography for Detection of Coronary Artery Stenoses
    Dewey, Marc
    Zimmermann, Elke
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Rutsch, Wolfgang
    Hamm, Bernd
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A265 - A265
  • [2] Assessing Regional Cerebral Blood Flow in Depression Using 320-Slice Computed Tomography
    Wang, Yiming
    Zhang, Hongming
    Tang, Songlin
    Liu, Xingde
    O'Neil, Adrienne
    Turner, Alyna
    Chai, Fangxian
    Chen, Fanying
    Berk, Michael
    [J]. PLOS ONE, 2014, 9 (09):
  • [3] Regional Cerebral Blood Flow in Mania: Assessment Using 320-Slice Computed Tomography
    Wang, Yiming
    Liu, Xingde
    Li, Peifan
    Zhou, Haiyan
    Yang, Lixia
    Zheng, Lei
    Xie, Pingxia
    Li, Lingjiang
    Liao, D. Joshua
    Liu, Qianqian
    Fang, Deyu
    [J]. FRONTIERS IN PSYCHIATRY, 2018, 9
  • [4] Detection of coronary artery anomalies in Chinese adults using 320-slice computed tomography
    Tang, Xixiang
    Chen, Yanming
    Peng, Long
    Dong, Ruimin
    Luo, Yanting
    Li, Suhua
    Liu, Jinlai
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C132 - C133
  • [5] Investigation of an optimized scanning protocol for the dentomaxillofacial region using 320-slice multidetector computed tomography
    Lin, Wei-Chan
    Wang, Hsueh-Han
    Hsu, Wen-Lin
    Cao, Bi-Hui
    Chen, De-Ji
    Tsai, Chia-Jung
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (04)
  • [6] Evaluation of electrical reconnection after pulmonary vein isolation using 320-slice computed tomography
    Motooka, M.
    Onishi, N.
    Hayama, Y.
    Nakajima, S.
    Miyake, M.
    Tamura, T.
    Kondou, H.
    Kaitani, K.
    Izumi, C.
    Nakagawa, Y.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 : 845 - 845
  • [7] Plaque Vulnerability Assessment by Coronary Artery Remodeling Using 320-Slice Computed Tomography Angiography
    Motoyama, Sadako
    Sarai, Masayoshi
    Kawai, Hideki
    Harigaya, Hiroto
    Naruse, Hiroyuki
    Ishii, Junnichi
    Ozaki, Yukio
    Narula, Jagat
    [J]. CIRCULATION, 2010, 122 (21)
  • [8] Digital 320-slice volume computed tomography scanning in the diagnosis of gastrointestinal lipoma
    Zhu, Z.
    Liu, H.
    Xu, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (02): : 349 - 352
  • [9] Is 320-Slice Computed Tomography Coronary Angiography Really Useful for Symptomatic Patients?
    Yamanaka, Futoshi
    Ooyama, Souma
    Tobita, Kazuki
    Shishido, Kouki
    Imori, Youichi
    Nomura, Yu
    Osaka, Yumiko
    Sugitatsu, Kazuya
    Okamura, Nobuhiro
    Mizuno, Shingo
    Arima, Ken
    Suenaga, Hidetaka
    Murakami, Masato
    Tanaka, Yutaka
    Matsumi, Junya
    Takahashi, Saeko
    Akasaka, Takeshi
    Takeshita, Satoshi
    Saito, Shigeru
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (07): : 125S - 125S
  • [10] Papillary Fibroelastoma of the Aortic Valve Visualized by 320-slice Computed Tomography: Report of a Case
    Kin, Hajime
    Koizumi, Junichi
    Yoshioka, Kunihiro
    Okabayashi, Hitoshi
    [J]. ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (05) : 518 - 520