Selection of voxel size and photon number in voxel-based Monte Carlo method: criteria and applications

被引:8
|
作者
Li, Dong [1 ]
Chen, Bin [1 ]
Ran, Wei Yu [1 ]
Wang, Guo Xiang [1 ,2 ]
Wu, Wen Juan [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
[2] Univ Akron, Dept Mech Engn, Akron, OH 44325 USA
基金
中国国家自然科学基金;
关键词
voxel-based Monte Carlo; grid size; photon number; local grid refinement; photon splitting; LIGHT DISTRIBUTIONS; BLOOD-VESSELS; TISSUE; TRANSPORT; MODEL; CODE; SKIN; MIGRATION; MEDIA;
D O I
10.1117/1.JBO.20.9.095014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The voxel-based Monte Carlo method (VMC) is now a gold standard in the simulation of light propagation in turbid media. For complex tissue structures, however, the computational cost will be higher when small voxels are used to improve smoothness of tissue interface and a large number of photons are used to obtain accurate results. To reduce computational cost, criteria were proposed to determine the voxel size and photon number in 3-dimensional VMC simulations with acceptable accuracy and computation time. The selection of the voxel size can be expressed as a function of tissue geometry and optical properties. The photon number should be at least 5 times the total voxel number. These criteria are further applied in developing a photon ray splitting scheme of local grid refinement technique to reduce computational cost of a nonuniform tissue structure with significantly varying optical properties. In the proposed technique, a nonuniform refined grid system is used, where fine grids are used for the tissue with high absorption and complex geometry, and coarse grids are used for the other part. In this technique, the total photon number is selected based on the voxel size of the coarse grid. Furthermore, the photon-splitting scheme is developed to satisfy the statistical accuracy requirement for the dense grid area. Result shows that local grid refinement technique photon ray splitting scheme can accelerate the computation by 7.6 times (reduce time consumption from 17.5 to 2.3 h) in the simulation of laser light energy deposition in skin tissue that contains port wine stain lesions. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Optimized Monte Carlo simulations for voxel-based internal dosimetry
    Cordeiro, Leanderson P.
    de Sa, Lidia, V
    Kitamikado, Rafael A.
    Sapienza, Marcelo T.
    Bonifacio, Daniel A. B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [2] InterDosi Monte Carlo simulations of photon and electron specific absorbed fractions in a voxel-based crab phantom
    Jaafar EL Bakkali
    Emily Caffrey
    Abderrahim Doudouh
    [J]. Radiation and Environmental Biophysics, 2022, 61 : 111 - 118
  • [3] InterDosi Monte Carlo simulations of photon and electron specific absorbed fractions in a voxel-based crab phantom
    El Bakkali, Jaafar
    Caffrey, Emily
    Doudouh, Abderrahim
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2022, 61 (01) : 111 - 118
  • [4] Voxel-based Monte Carlo simulation for light propagation in inhomogeneous turbid media
    Ishii, Katsuhiro
    Okada, Tatsuhiro
    Nishidate, Izumi
    Iwai, Toshiaki
    [J]. DIFFUSE OPTICAL IMAGING IV, 2013, 8799
  • [5] Effect of voxel size on Monte Carlo dose calculations
    Qin, L
    Yang, J
    Li, J
    Chen, L
    Price, R
    Ma, C
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1883 - 1883
  • [6] Voxel-based Monte Carlo simulation of human external exposure to terrestrial gamma radiation
    Bouzouita, A.
    Askri, B.
    Manai, K.
    Trabelsi, A.
    [J]. Radioprotection, 2024, 59 (04) : 296 - 305
  • [7] Voxel-based Monte Carlo simulation of X-ray imaging and spectroscopy experiments
    Bottigli, U
    Brunetti, A
    Golosio, B
    Oliva, P
    Stumbo, S
    Vincze, L
    Randaccio, P
    Bleuet, P
    Simionovici, A
    Somogyi, A
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1747 - 1754
  • [8] Modeling voxel-based Monte Carlo light transport with curved and oblique boundary surfaces
    Anh Phong Tran
    Jacques, Steven L.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (02)
  • [9] A voxel-based mouse for internal dose calculations using Monte Carlo simulations (MCNP)
    Bitar, A.
    Lisbona, A.
    Thedrez, P.
    Maurel, C. Sai
    Le Forestier, D.
    Barbet, J.
    Bardies, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (04): : 1013 - 1025
  • [10] A Voxel-Based Monte Carlo Model of Drug Release from Bulk Eroding Nanoparticles
    Eavarone, David A.
    Soundararajan, Venkataramanan
    Haller, Toomas
    Sasisekharan, Ram
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2010, 10 (09) : 5903 - 5907