Effect of injection energy on residual dose around the charge exchange foil

被引:2
|
作者
Yamamoto, Kazami [1 ]
Kato, Shinichi [2 ]
机构
[1] JAEA, Tokai, Ibaraki 3191195, Japan
[2] Tohoku Univ, Sendai, Miyagi 9808578, Japan
关键词
D O I
10.1103/PhysRevSTAB.15.120401
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The rapid cycling synchrotron (RCS) of Japan Proton Accelerator Research Complex (J-PARC) and the accumulator ring (AR) of Spallation Neutron Source (SNS) can be used as high-power pulsed neutron sources. In both cases, the injection region becomes one of the highest activation areas in the ring. However, residual dose distributions have revealed that the highest activation points in the J-PARC RCS and the SNS AR are different in detail. The dose of the charge exchange chamber in the SNS is more than 100 times larger than that of the RCS though the ratio of beam power is less than 10. We investigated the reason of this difference by GEANT4 and MARS, and the calculation results indicated that the difference was due to the dependence of the neutron and pion production rate on the injection energy. DOI: 10.1103/PhysRevSTAB.15.120401
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Effect of Incident Energy and Foil Thickness on Foil Stripping and Scattering Efficiency in Charge Exchange Analyzer Detector
    Kazemi, M.
    Habibi, M.
    Tafreshi, M.
    JOURNAL OF FUSION ENERGY, 2012, 31 (02) : 179 - 183
  • [2] Effect of Incident Energy and Foil Thickness on Foil Stripping and Scattering Efficiency in Charge Exchange Analyzer Detector
    M. Kazemi
    M. Habibi
    M. Tafreshi
    Journal of Fusion Energy, 2012, 31 : 179 - 183
  • [3] Effect of impurities in charge-exchange carbon foil on foil thickness reduction
    Takeda, Yasuhiro
    Kadono, Toshiharu
    VACUUM, 2012, 86 (07) : 899 - 902
  • [4] Residual energy and space charge effect
    He, B
    Chang, TQ
    Chen, SG
    Nie, XB
    Zhang, JT
    Xu, LB
    LASER INTERACTION AND RELATED PLASMA PHENOMENA - 13TH INTERNATIONAL CONFERENCE, 1997, (406): : 571 - 577
  • [5] A NEW TYPE OF STRIPPING CARBON FOIL FOR H- CHARGE-EXCHANGE INJECTION INTO A SYNCHROTRON
    YAMANE, I
    YAMAGUCHI, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 254 (02): : 225 - 228
  • [6] NEW TYPE OF STRIPPING CARBON FOIL FOR H - CHARGE-EXCHANGE INJECTION INTO A SYNCHROTRON.
    Yamane, Isao
    Yamaguchi, Hiroshi
    Nuclear instruments and methods in physics research, 1987, A254 (02): : 225 - 228
  • [7] CALCULATION OF RESIDUAL PHOTON DOSE RATE AROUND HIGH-ENERGY PROTON ACCELERATORS
    ARMSTRON.TW
    ALSMILLE.RG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (01): : 391 - &
  • [8] CALCULATION OF RESIDUAL PHOTON DOSE RATE AROUND HIGH-ENERGY PROTON ACCELERATORS
    ARMSTRONG, TW
    ALSMILLER, RG
    NUCLEAR SCIENCE AND ENGINEERING, 1969, 38 (01) : 53 - +
  • [9] REDUCTION OF RESIDUAL PHOTON DOSE RATE AROUND HIGH-ENERGY PROTON ACCELERATORS
    ARMSTRONG, TW
    BARISH, J
    NUCLEAR SCIENCE AND ENGINEERING, 1970, 40 (01) : 129 - +
  • [10] CHARGE-EXCHANGE INJECTION AT THE AGS
    BARTON, DS
    AHRENS, LA
    GILL, E
    GLENN, JW
    REECE, RK
    WITKOVER, RL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (04) : 2787 - 2789