Role of Pulsatility in Hypothermic Reconditioning of Porcine Kidney Grafts by Machine Perfusion After Cold Storage

被引:67
|
作者
Gallinat, Anja [1 ]
Fox, Mario [2 ]
Lueer, Bastian [2 ]
Efferz, Patrik [2 ]
Paul, Andreas [1 ]
Minor, Thomas [2 ]
机构
[1] Univ Hosp Essen, Clin Gen Visceral & Transplantat Surg, Essen, Germany
[2] Univ Clin Surg, Div Surg Res, D-53127 Bonn, Germany
关键词
Machine perfusion; Pulsatility; Endothelium; Renovaculature; ENDOTHELIAL DYSFUNCTION; PRESERVATION; TRANSPLANTATION; DONORS; REPERFUSION; INJURY;
D O I
10.1097/TP.0b013e31829c24e2
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Brief in-house machine perfusion after cold storage (CS) (hypothermic reconditioning) has been proposed as a convenient tool to improve kidney graft function. The present study aimed to investigate the mechanistic role of vascular pulsatility in this context. Methods. Kidney function after cold preservation (4 degrees C, 18 hr) and subsequent reconditioning by 90 min of pulsatile machine perfusion (PP) (30/20 mm Hg) or nonpulsatile machine perfusion (NPP) (30 mm Hg) was studied in an isolated kidney perfusion model in pigs (n=6 for both) and compared with simply CS grafts. Results. Compared with CS, PP but not NPP significantly improved renal perfusate flow and urine production and significantly increased the reduction of perfusate levels of creatinine and urea during reperfusion. Perfusate levels of fatty acid binding protein, a marker of tubular cell injury, were dramatically reduced by PP but not NPP. PP and NPP lowered fractional excretion of sodium, but significance was only reached for PP. Molecular effects of PP comprised a significant (vs. CS) mRNA elevation of the endothelial anti-inflammatory transcription factor Kruppel-like factor 2 as well as endothelial nitric oxide synthase, along with significantly higher perfusate levels of the endogenous vasodilator nitric oxide. Functional efficiency of PP over CS was confirmed in additional porcine transplant experiments (n=5 for both) by, for example, up to threefold improved clearance of creatinine during the first days after transplantation. Conclusion. PP of 90 min shortly before transplantation seems to be an efficient mechanism to reduce proinflammatory endothelial phenotype and improve functional outcome of kidney grafts even after preceding static storage.
引用
收藏
页码:538 / 542
页数:5
相关论文
共 50 条
  • [1] ROLE OF PULSATILITY IN HYPOTHERMIC RECONDITIONING OF PORCINE KIDNEY GRAFTS BY MACHINE PERFUSION AFTER COLD STORAGE
    Gallinat, Anja
    Fox, Mario
    Lueer, Bastian
    Paul, Andreas
    Minor, Thomas
    TRANSPLANT INTERNATIONAL, 2013, 26 : 57 - 57
  • [2] Hypothermic Reconditioning of Porcine Kidney Grafts by Short-Term Preimplantation Machine Perfusion
    Gallinat, Anja
    Paul, Andreas
    Efferz, Patrik
    Lueer, Bastian
    Kaiser, Gernot
    Wohlschlaeger, Jeremias
    Treckmann, Juergen
    Minor, Thomas
    TRANSPLANTATION, 2012, 93 (08) : 787 - 793
  • [3] RECONDITIONING EFFECT OF THE HYPOTHERMIC MACHINE PERFUSION ON KIDNEY GRAFTS WITH COLD ISCHEMIA TIME OVER 24 HOURS
    Adani, Gian Luigi
    Pravisani, Riccardo
    Baccarani, Umberto
    Scott, Cathryn
    Tulissi, Patrizia
    Vallone, Clotilde
    Di Loreto, Carla
    Risaliti, Andrea
    TRANSPLANT INTERNATIONAL, 2019, 32 : 303 - 303
  • [4] Hypothermic reconditioning by gaseous oxygen persufflation after cold storage of porcine kidneys
    Minor, Thomas
    Efferz, Patrik
    Lueer, Bastian
    CRYOBIOLOGY, 2012, 65 (01) : 41 - 44
  • [5] The Effect of Hypothermic Machine Perfusion and Cold Storage for Kidney Preservation
    Chusri, Yanee
    Gesprasert, Goragoch
    Khienwad, Thananya
    Naiyanate, Phornphop
    2017 10TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2017,
  • [6] Hypothermic machine perfusion after static cold storage does not improve the preservation condition in an experimental porcine kidney model
    Hosgood, S. A.
    Mohamed, I. H.
    Bagul, A.
    Nicholson, M. L.
    BRITISH JOURNAL OF SURGERY, 2011, 98 (07) : 943 - 950
  • [7] Hypothermic machine perfusion after static cold storage does not improve the preservation condition in an experimental porcine kidney model
    Hosgood, Sarah A.
    Bagul, Atul
    Mohamed, Ismail H.
    Nicholson, Michael L.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 30 - 30
  • [8] Hypothermic machine perfusion versus static cold storage in a porcine kidney model of ischaemia reperfusion injury
    Hosgood, Sarah A.
    Mohamed, Ismail H.
    Yang, Bin
    Bagul, Atul
    Nicholson, Michael L.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : 8 - 8
  • [9] Hypothermic reconditioning after cold storage improves postischemic graft function in isolated porcine kidneys
    Koetting, Martina
    Frotscher, Carolin
    Minor, Thomas
    TRANSPLANT INTERNATIONAL, 2010, 23 (05) : 538 - 542
  • [10] Hypothermic Machine Perfusion of Kidney Grafts: Which Pressure is Preferred?
    Doorschodt, B. M.
    Schreinemachers, M. C. J. M.
    Behbahani, M.
    Florquin, S.
    Weis, J.
    Staat, M.
    Tolba, R. H.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (03) : 1051 - 1059