Two-dimensional spatially-selective RF excitation pulses in echo-planar Imaging

被引:123
|
作者
Rieseberg, S [1 ]
Frahm, J [1 ]
Finsterbusch, J [1 ]
机构
[1] Max Planck Inst Biophys Chem, Biomed NMR Forsch GmbH, D-37070 Gottingen, Germany
关键词
magnetic resonance imaging; zoom imaging; localized imaging; 2D-selective RF excitation; echo-planar imaging;
D O I
10.1002/mrm.10157
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two-dimensional spatially-selective RF (2DRF) excitation pulses were developed for single-shot echo-planar imaging (EPI) with reduced field of view (FOV) in the phase-encoding direction. The decreased number of k-space lines significantly shortens the length of the EPI echo train. Thus, both gradient-echo and spin-echo 2DRF-EPI images of the human brain at 2.0 T exhibit markedly reduced susceptibility artifacts in regions close to major air cavities. Based on a blipped-planar trajectory, implementation of a typical 2DRF pulse resulted in a 26-ms pulse duration, a 5-mm section thickness, a 40-mm FOV along the phase-encoding direction, and a 200-mm distance of the unavoidable side excitations from the center of the FOV. For the above conditions and at 2 x 2 mm(2) resolution, 2DRF-EPI yielded an echo train length of only 21 ms, as opposed to 102 ms for conventional EPI. This gain in time may be used to achieve higher spatial resolution. For example, spin-echo 2DRF-EPI of a 40-mm FOV at 1 x 1 mm(2) resolution led to an echo train of 66 ms. Although the current implementation still lacks user-friendliness, 2DRF pulses are likely to become a useful addition to the arsenal of advanced MRI tools.
引用
收藏
页码:1186 / 1193
页数:8
相关论文
共 50 条
  • [1] Calibration of echo-planar 2D-selective RF excitation pulses
    Oelhafen, M
    Pruessmann, KP
    Kozerke, S
    Boesiger, P
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1136 - 1145
  • [2] Reduced field-of-view MRI with two-dimensional spatially-selective RF excitation and UNFOLD
    Zhao, L
    Madore, B
    Panych, LP
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 1118 - 1125
  • [3] Zoomed EPI-DWI of the Pancreas Using Two-Dimensional Spatially-Selective Radiofrequency Excitation Pulses
    Riffel, Philipp
    Michaely, Henrik J.
    Morelli, John N.
    Pfeuffer, Josef
    Attenberger, Ulrike I.
    Schoenberg, Stefan O.
    Haneder, Stefan
    PLOS ONE, 2014, 9 (03):
  • [4] Zoomed EPI-DWI of the head and neck with two-dimensional, spatially-selective radiofrequency excitation pulses
    Riffel, Philipp
    Michaely, Henrik J.
    Morelli, John N.
    Pfeuffer, Josef
    Attenberger, Ulrike I.
    Schoenberg, Stefan O.
    Haneder, Stefan
    EUROPEAN RADIOLOGY, 2014, 24 (10) : 2507 - 2512
  • [5] Zoomed EPI-DWI of the head and neck with two-dimensional, spatially-selective radiofrequency excitation pulses
    Philipp Riffel
    Henrik J. Michaely
    John N. Morelli
    Josef Pfeuffer
    Ulrike I. Attenberger
    Stefan O. Schoenberg
    Stefan Haneder
    European Radiology, 2014, 24 : 2507 - 2512
  • [6] The Evaluation of Zoomed Echo-Planar Diffusion-Weighted Magnetic Resonance Imaging With Two-dimensional Spatial-Selective Radiofrequency Excitation Pulses in Patients With Hilar Cholangiocarcinoma
    Liu, Jingjing
    Huang, Mengyue
    Ren, Yanan
    Xu, Man
    Li, Yinhua
    Cheng, Jingliang
    Zhu, Jinxia
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [7] A flexible two-dimensional phase correction for interleaved echo-planar imaging reconstruction
    Liu, HY
    JOURNAL OF APPLIED PHYSICS, 1998, 83 (11) : 6846 - 6848
  • [8] Flexible two-dimensional phase correction for interleaved echo-planar imaging reconstruction
    Liu, Haiying
    Journal of Applied Physics, 1998, 83 (11 pt 2):
  • [9] Combining Two-Dimensional Spatially Selective RF Excitation, Parallel Imaging, and UNFOLD for Accelerated MR Thermometry Imaging
    Mei, Chang-Sheng
    Panych, Lawrence P.
    Yuan, Jing
    McDannold, Nathan J.
    Treat, Lisa H.
    Jing, Yun
    Madore, Bruno
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 112 - 122
  • [10] Two-dimensional multishot echo-planar coronary MR angiography
    Slavin, GS
    Riederer, SJ
    Ehman, RL
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) : 883 - 889