Energy saving potential of a simple control strategy for heat exchanger network operation under fouling conditions

被引:19
|
作者
Trafczynski, Marian [1 ]
Markowski, Mariusz [1 ]
Urbaniec, Krzysztof [1 ]
机构
[1] Warsaw Univ Technol, Fac Civil Engn Mech & Petrochem, Inst Mech Engn, Dept Proc Equipment, Lukasiewicza 17, PL-09400 Plock, Poland
来源
关键词
Heat exchanger network; Preheat train; Optimal operation; Near-optimal control; Control strategy; Energy saving; SELF-OPTIMIZING CONTROL; CLEANING SCHEDULE; OPTIMIZATION; INTEGRATION; INDUSTRIAL;
D O I
10.1016/j.rser.2019.05.046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A real-life benchmark system comprising a Heat Exchanger Network operated as part of Crude Distillation Unit is considered. In such systems, the crude oil stream is typically split into parallel branches and the oil mass flows through the branches are kept in constant proportion, i.e., at constant split ratio, by the process control system. In this paper, linear control systems (proportional-integral-derivative controllers) are considered and the proposed control strategy is to adjust the parallel flows so that identical temperature values are maintained at the outlets from two parallel branches and consequently, the heat recovery in the network is maximized. The aim is to enhance the energy efficiency of the system and minimise greenhouse gas emissions. A mathematical model of the heat exchanger network was built and validated on the basis of real-life data recorded during operation of the crude distillation unit. Using MATLAB/Simulink, closed-loop control was simulated to enable comparative evaluation of the studied strategy of proportional-integral-derivative control and its potential to achieve energy savings in the operation of the distillation unit under fouling conditions. Compared to the strategy of constant split ratio, the proposed strategy of equal outlet temperatures from the network branches was found to increase the total heat recovery by about 1.5%. In the studied operation period, the heat-recovery increase fluctuated in the range 150-1100 kW and the average daily energy saving was estimated at 18 MWh.
引用
收藏
页码:355 / 364
页数:10
相关论文
共 50 条
  • [1] On-line control of the heat exchanger network under fouling constraints
    Markowski, Mariusz
    Trzcinski, Przemyslaw
    ENERGY, 2019, 185 (521-526) : 521 - 526
  • [2] The energy saving potential of a rotary heat exchanger with bypass dampers
    Zmrhal, Vladimir
    ENERGY AND BUILDINGS, 2023, 285
  • [3] Evaluation of Crude Oil Heat Exchanger Network Fouling Behavior Under Aging Conditions for Scheduled Cleaning
    Diaby, Abdullatif Lacina
    Miklavcic, Stanley Joseph
    Bari, Saiful
    Addai-Mensah, Jonas
    HEAT TRANSFER ENGINEERING, 2016, 37 (15) : 1211 - 1230
  • [4] Operational cost minimization in heat exchanger network under milk fouling
    Deka, Dimbalita
    Datta, Dilip
    2017 INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL, INDUSTRIAL, AUTOMATION AND MANAGEMENT SYSTEMS (AMIAMS) - PROCEEDINGS, 2017, : 59 - 63
  • [5] Heat exchanger network retrofit under fouling effects with cleaning schedule
    Yanyongsak J.
    Siemanond K.
    Chemical Engineering Transactions, 2018, 70 : 1549 - 1554
  • [7] Robust model predictive control of heat exchanger network in the presence of fouling
    Oravec J.
    Trafczynski M.
    Bakošová M.
    Markowski M.
    Mészáros A.
    Urbaniec K.
    Oravec, Juraj (juraj.oravec@stuba.sk), 1600, Italian Association of Chemical Engineering - AIDIC (61): : 337 - 342
  • [8] Optimal energy and cleaning management in heat exchanger networks under fouling
    Georgiadis, MC
    Papageorgiou, LG
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A2): : 168 - 179
  • [9] ENERGY INCREASE IN OPERATION AND CLEANING DUE TO HEAT-EXCHANGER FOULING IN MILK PASTEURIZATION
    SANDU, C
    SINGH, RK
    FOOD TECHNOLOGY, 1991, 45 (12) : 84 - 91
  • [10] Reliable simultaneous operation strategy in heat exchanger networks under variable heat loads
    Chen, Qun
    Zhang, Meng-Qi
    Dong, En-Fu
    Wang, Yi-Fei
    Sui, Yu-Qiu
    APPLIED THERMAL ENGINEERING, 2019, 149 (1125-1133) : 1125 - 1133