A concept for canceling the leakage field inside the stored beam chamber of a septum magnet

被引:7
|
作者
Abliz, M. [1 ]
Jaski, M. [1 ]
Xiao, A. [1 ]
Jain, A. [1 ]
Wienands, U. [1 ]
Cease, H. [1 ]
Borland, M. [1 ]
Decker, G. [1 ]
Kerby, J. [1 ]
机构
[1] Argonne Natl Lab, 9700 S Cass Ave, Argonne, IL 60439 USA
关键词
Magnet design; Septum magnet; Leakage field; Injected beam; Beam trajectories;
D O I
10.1016/j.nima.2017.11.090
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Advanced Photon Source (APS) is planning to upgrade its storage ring from a double-bend achromat to a multi-bend achromat lattice as part of the APS Upgrade Project (APS-U). A swap-out injection scheme is planned for the APS-U in order to keep the beam current constant and to reduce the dynamic aperture requirements. The injection scheme, combined with the constraints in the booster to storage ring transfer region of the APS-U, results in requiring a septum magnet which deflects the injected 6 GeV electron beam by 89 mrad, while not appreciably disturbing the stored beam. The proposed magnet is straight; however, it is rotated in yaw, roll, and pitch from the stored beam chamber to meet the on-axis swap-out injection requirements for the APS-U lattice. The concept utilizes cancellation of the leakage field inside the 8 mm x 6 mm super-ellipsoidal stored beam chamber. As a result, the horizontal deflection angle of the 6 GeV stored beam is reduced to less than 1 mu rad with only a 2-mm-thick septum separating the stored beam and the 1.06 T field seen by the injected beam. This design also helps to minimize the integrated skew quadrupole and normal sextupole fields inside the stored beam chamber. Published by Elsevier B.V.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 6 条
  • [1] Optimization design and measurement of septum magnet with low leakage field
    Wei, Yanqun
    Zhang, Jingjing
    Hu, Qiang
    Ma, Lizhen
    Yao, Zeen
    Yang, Jing
    Jin, Lian
    Yao, Qinggao
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2024, 75 (04) : 445 - 457
  • [2] Beam-based design of a correction coil for the stray field of a pulse septum magnet
    Mitsui, Takayuki
    Matsubara, Takahiro
    Hisaoka, Yoshinori
    Shoji, Yoshihiko
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 1521 - 1524
  • [3] DC Septum magnets and their leakage field effects on an electron beam in the SPring-8 storage ring
    Tsumaki, K
    Shimada, T
    Kajimoto, K
    Yonehara, H
    Kumagai, N
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 433 - 436
  • [4] POTENTIAL AND FIELD PRODUCED BY A UNIFORM OR NONUNIFORM ELLIPTICAL BEAM INSIDE A CONFOCAL ELLIPTIC VACUUM CHAMBER
    REGENSTREIF, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (03) : 1443 - 1445
  • [5] POTENTIAL AND FIELD PRODUCED BY A UNIFORM OR NONUNIFORM ELLIPTICAL BEAM INSIDE A CONFOCAL ELLIPTIC VACUUM CHAMBER
    REGENSTREIF, E
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (02): : 150 - 150
  • [6] Double-Field Hadrontherapy Treatment Monitoring With the INSIDE In-Beam PET Scanner: Proof of Concept
    Ferrero, Veronica
    Bisogni, Maria Giuseppina
    Camarlinghi, Niccolo'
    Fiorina, Elisa
    Giraudo, Giuseppe
    Morrocchi, Matteo
    Pennazio, Francesco
    Sportelli, Giancarlo
    Wheadon, Richard
    Cerello, Piergiorgio
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (06) : 588 - 593