Validation Study of a Virtual Reality Robotic Simulator-Role as an Assessment Tool?

被引:79
|
作者
Lee, Jason Y. [1 ]
Mucksavage, Phillip
Kerbl, David C.
Huynh, Victor B.
Etafy, Mohamed
McDougall, Elspeth M.
机构
[1] Univ Toronto, St Michaels Hosp, Div Urol, Toronto, ON M5B 1W8, Canada
来源
JOURNAL OF UROLOGY | 2012年 / 187卷 / 03期
关键词
urology; robotics; surgery; clinical competence; education; medical; LAPAROSCOPIC SURGERY; PERFORMANCE; SKILLS;
D O I
10.1016/j.juro.2011.10.160
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Virtual reality simulators are often used for surgical skill training since they facilitate deliberate practice in a controlled, low stakes environment. However, to be considered for assessment purposes rigorous construct and criterion validity must be demonstrated. We performed face, content, construct and concurrent validity testing of the dV-Trainer (TM) robotic surgical simulator. Materials and Methods: Urology residents, fellows and attending surgeons were enrolled in this institutional review board approved study. After a brief introduction to the dV-Trainer each subject completed 3 repetitions each of 4 virtual reality tasks on it, including pegboard ring transfer, matchboard object transfer, needle threading of rings, and the ring and rail task. One week later subjects completed 4 similar tasks using the da Vinci (R) robot. Subjects were assessed on total task time and total errors using the built-in scoring algorithm and manual scoring for the dV-Trainer and the da Vinci robot, respectively. Results: Seven experienced and 13 novice robotic surgeons were included in the study. Experienced surgeons were defined by greater than 50 hours of clinical robotic console time. Of novice robotic surgeons 77% ranked the dV-Trainer as a realistic training platform and 71% of experienced robotic surgeons ranked it as useful for resident training. Experienced robotic surgeons outperformed novices in many dV-Trainer and da Vinci robot exercises, particularly in the number of errors. On pooled data analysis dV-Trainer total task time and total errors correlated with da Vinci robot total task time and total errors (p = 0.026 and 0.011, respectively). Conclusions: This study confirms the face, content, construct and concurrent validity of the dV-Trainer, which may have a potential role as an assessment tool.
引用
收藏
页码:998 / 1002
页数:5
相关论文
共 50 条
  • [1] CONSTRUCT AND CONCURRENT VALIDATION STUDY OF A VIRTUAL REALITY ROBOTIC SIMULATOR
    Lee, Jason Y.
    Mucksavage, Phillip
    Kerbl, David C.
    Etafy, Mohammed
    Huyhn, Victor B.
    McDougall, Elspeth M.
    [J]. JOURNAL OF ENDOUROLOGY, 2011, 25 : A285 - A285
  • [2] Validation of a Novel Virtual Reality Robotic Simulator
    Sethi, Amanjot S.
    Peine, William J.
    Mohammadi, Yousef
    Sundaram, Chandru P.
    [J]. JOURNAL OF ENDOUROLOGY, 2009, 23 (03) : 503 - 508
  • [3] Validation of a Novel Virtual Reality Simulator for Robotic Surgery
    Schreuder, Henk W. R.
    Persson, Jan E. U.
    Wolswijk, Richard G. H.
    Ihse, Ingmar
    Schijven, Marlies P.
    Verheijen, Rene H. M.
    [J]. SCIENTIFIC WORLD JOURNAL, 2014,
  • [4] Initial validation of a virtual-reality robotic simulator
    Lendvay T.S.
    Casale P.
    Sweet R.
    Peters C.
    [J]. Journal of Robotic Surgery, 2008, 2 (3) : 145 - 149
  • [5] Face and construct validation of a novel virtual reality robotic simulator
    Sethi, Amanjot S.
    Peine, William J.
    Mohammadi, Yousef
    Gardner, Thomas A.
    Koch, Michael O.
    Sundaram, Chandru P.
    [J]. JOURNAL OF UROLOGY, 2008, 179 (04): : 660 - 660
  • [6] The virtual reality simulator dV-TrainerA® is a valid assessment tool for robotic surgical skills
    Perrenot, Cyril
    Perez, Manuela
    Nguyen Tran
    Jehl, Jean-Philippe
    Felblinger, Jacques
    Bresler, Laurent
    Hubert, Jacques
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (09): : 2587 - 2593
  • [7] The virtual reality simulator dV-Trainer® is a valid assessment tool for robotic surgical skills
    Cyril Perrenot
    Manuela Perez
    Nguyen Tran
    Jean-Philippe Jehl
    Jacques Felblinger
    Laurent Bresler
    Jacques Hubert
    [J]. Surgical Endoscopy, 2012, 26 : 2587 - 2593
  • [8] A Study on the Learning Curve of the Robotic Virtual Reality Simulator
    Kang, Sung Gu
    Yang, Kyung Sook
    Ko, Young Hwii
    Kang, Seok Ho
    Park, Hong Seok
    Lee, Jeong Gu
    Kim, Je Jong
    Cheon, Jun
    [J]. JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2012, 22 (05): : 438 - 442
  • [9] VALIDATION OF THE DV-TRAINER®, A NOVEL VIRTUAL REALITY SIMULATOR FOR ROBOTIC SURGERY
    Kenney, Patrick A.
    Wszolek, Matthew F.
    Gould, Justin J.
    Libertino, John A.
    Moinzadeh, Alireza
    [J]. JOURNAL OF UROLOGY, 2009, 181 (04): : 792 - 792
  • [10] A driving simulator as a virtual reality tool
    Lee, WS
    Kim, JH
    Cho, JH
    [J]. 1998 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, 1998, : 71 - 76