Mini-implants and narrow diameter implants as mandibular overdenture retainers: A systematic review and meta-analysis of clinical and radiographic outcomes

被引:50
|
作者
Marcello-Machado, R. M. [1 ]
Faot, F. [2 ]
Schuster, A. J. [3 ]
Nascimento, G. G. [4 ]
Del Bel Cury, A. A. [5 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Piracicaba, SP, Brazil
[2] Univ Fed Pelotas, Sch Dent, Dept Restorat Dent, Pelotas, RS, Brazil
[3] Univ Fed Pelotas, Grad Program Dent, Sch Dent, Pelotas, RS, Brazil
[4] Aarhus Univ, Dept Dent & Oral Hlth, Aarhus, Denmark
[5] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Piracicaba, Brazil
关键词
edentulous; jaw; meta-analysis; mini-implant; narrow dental implants; overdenture; systematic review; RANDOMIZED CONTROLLED-TRIAL; QUALITY-OF-LIFE; TITANIUM-ZIRCONIUM IMPLANTS; MARGINAL BONE LOSS; DENTAL IMPLANTS; ITI-IMPLANTS; RETROSPECTIVE ANALYSIS; SUPPORTED OVERDENTURE; PATIENT SATISFACTION; MASTICATORY FUNCTION;
D O I
10.1111/joor.12585
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study reviews the clinical and radiographic outcomes of Mini-implants (MI) and Narrow Diameter Implants (NDI) as mandibular overdenture (MO) retainers. Six databases were consulted for clinical studies that evaluated implants with diameter 3.5mm. Data on the MI and NDI for survival and success rate and peri-implant bone loss and were collected and submitted to meta-analysis. Thirty-six studies were included, 24 reporting MI performance and 12 describing NDI results. The MI group comprised data from 1 cross-sectional clinical study, 3 retrospective longitudinal (RL) clinical studies, 13 prospective longitudinal (PL) clinical studies and 7 randomised clinical trials (RCT) with follow-up periods ranging from 1day to 7years. Eight studies used conventional loading, thirteen used immediate loading, two studies used both loading types, and one study did not report. The NDI group comprised data from 3 RL clinical studies, 6 PL clinical studies and 3 RCT with follow-up ranging from 6months to 10years. Ten studies used conventional loading, 1 study used immediate loading, and 1 study did not report. The average survival rates of MI and NDI studies were 98% and 98%, respectively, while the average success rates were 93% and 96%, respectively. The average peri-implant bone loss after 12, 24 and 36months was 0.89, 1.18 and 1.02mm for MI and 0.18, 0.12 and -0.32mm for NDI. Both MI and NDI showed adequate clinical behaviour as overdenture retainers. The NDI showed a better long-term predictability to retain OM with most studies adopting conventional loading.
引用
收藏
页码:161 / 183
页数:23
相关论文
共 50 条
  • [1] Factors and clinical outcomes for standard and mini-implants retaining mandibular overdentures: A systematic review and meta-analysis
    Borges, Guilherme Almeida
    Codello, Denise Juncom
    Silva, Leticia Del Rio
    Dini, Caroline
    Barao, Valentim Adelino Ricardo
    Mesquita, Marcelo Ferraz
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 677 - 689
  • [2] Narrow-diameter implants: A systematic review and meta-analysis
    Schiegnitz, Eik
    Al-Nawas, Bilal
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 21 - 40
  • [3] The Clinical Performance of Narrow Diameter Implants Versus Regular Diameter Implants: A Meta-Analysis
    Ma, Meng
    Qi, Mengxing
    Zhang, Dongsheng
    Liu, Hongchen
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (06) : 503 - 508
  • [4] Narrow-diameter versus regular-diameter dental implants for mandibular overdentures: A systematic review and meta-analysis
    Park, Jin-Hong
    Shin, Sang-Wan
    Lee, Jeong-Yol
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (08): : 669 - 678
  • [5] Barriers and facilitators to the implementation of orthodontic mini-implants in clinical practice: A protocol for a systematic review and meta-analysis
    Meursinge Reynders R.
    Ronchi L.
    Ladu L.
    Di Girolamo N.
    de Lange J.
    Roberts N.
    Mickan S.
    [J]. Systematic Reviews, 5 (1)
  • [6] The effect of surface roughening on the success of orthodontic mini-implants: A systematic review and meta-analysis
    van den Braak, Matheus C. T.
    Hoekstra, Jan Willem M.
    Bronkhorst, Ewald M.
    Schols, Jan G. J. H.
    Ongkosuwito, Edwin M.
    Meijer, Gert J.
    van den Beucken, Jeroen J. J. P.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 165 (03) : 262 - 271.e3
  • [7] Risk factors associated with the stability of mini-implants and mini-plates: systematic review and meta-analysis
    de Mattos, Paola Marques
    Goncalves, Flavio Magno
    Basso, Isabela Bittencourt
    Zeigelboim, Bianca Simone
    Niwa, Marcio Furtado
    Stechman-Neto, Jose
    Santos, Rosane Sampaio
    de Araujo, Cristiano Miranda
    Guariza-Filho, Odilon
    [J]. CLINICAL ORAL INVESTIGATIONS, 2022, 26 (01) : 65 - 82
  • [8] Risk factors associated with the stability of mini-implants and mini-plates: systematic review and meta-analysis
    Paola Marques de Mattos
    Flavio Magno Gonçalves
    Isabela Bittencourt Basso
    Bianca Simone Zeigelboim
    Marcio Furtado Niwa
    José Stechman-Neto
    Rosane Sampaio Santos
    Cristiano Miranda de Araujo
    Odilon Guariza-Filho
    [J]. Clinical Oral Investigations, 2022, 26 : 65 - 82
  • [9] Clinical outcomes of pterygoid implants: Systematic review and meta-analysis
    Araujo, Rafael Zetehaku
    Santiago Junior, Joel Ferreira
    Cardoso, Camila Lopes
    Benites Condezo, Anthony Froy
    Moreira Junior, Rosenvaldo
    Curi, Marcos Martins
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (04) : 651 - 660
  • [10] Clinical outcomes of zirconia implants: a systematic review and meta-analysis
    Mohseni, Parvin
    Soufi, Ahmad
    Chrcanovic, Bruno Ramos
    [J]. CLINICAL ORAL INVESTIGATIONS, 2023, 28 (01)