Fabrication of a bismuth nanoparticle/Nafion modified screen-printed graphene electrode for in situ environmental monitoring

被引:19
|
作者
Palisoc, Shirley [1 ,2 ]
Sow, Vince Aaron [1 ]
Natividad, Michelle [1 ,2 ]
机构
[1] De La Salle Univ, Condensed Matter Phys Lab, Manila 922, Philippines
[2] De La Salle Univ, CENSER, Condensed Matter Res Unit, 2401 Taft Ave, Manila 922, Philippines
关键词
LEAD; SPECTROSCOPY; CADMIUM; SENSOR; OXIDE;
D O I
10.1039/c9ay00221a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bismuth nanoparticle (BiNP)/Nafion modified screen-printed electrodes were fabricated through screen printing and drop coating. Detection of Lead (Pb2+) and cadmium (Cd2+) was performed via anodic stripping voltammetry (ASV). Optimum values of the deposition time (60 seconds) and scan rate (50 mV s(-1)) were obtained and utilized in the selection of the best BiNP modifier concentration of 1.0 mg. The fabricated electrodes were optimized by cyclic voltammetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. The Limit of detection was found to be 280 parts per trillion and 40.34 parts per billion (ppb) for Lead and cadmium, respectively. Real samples of filtered tap water, unfiltered tap water, treated wastewater, and water obtained from Manila Bay were analyzed through ASV and atomic absorption spectroscopy (AAS). The Manila Bay water samples contained Lead and cadmium Levels far beyond safe Limits set forth by the U.S. EPA and World Health Organization while trace amounts of Lead (1-2 ppb) were detected in the other water samples. The treated wastewater contained the Least amount of Lead while the unfiltered tap water contained the highest concentration of Lead. Nonetheless, these trace amounts are well within tolerance Levels set forth by government agencies. The presence of heavy metals in all water samples was validated by AAS analysis.
引用
收藏
页码:1591 / 1603
页数:13
相关论文
共 50 条
  • [1] Determination of vanillin by using gold nanoparticle-modified screen-printed carbon electrode modified with graphene quantum dots and Nafion
    Duran, Gema M.
    Llorent-Martinez, Eulogio J.
    Contento, Ana M.
    Rios, Angel
    MICROCHIMICA ACTA, 2018, 185 (03)
  • [2] Determination of vanillin by using gold nanoparticle-modified screen-printed carbon electrode modified with graphene quantum dots and Nafion
    Gema M. Durán
    Eulogio J. Llorent-Martínez
    Ana M. Contento
    Ángel Ríos
    Microchimica Acta, 2018, 185
  • [3] A nickel nanoparticle/nafion-graphene oxide modified screen-printed electrode for amperometric determination of chemical oxygen demand
    Baojian Zhang
    Liming Huang
    Meihua Tang
    Kenneth W. Hunter
    Yan Feng
    Qianwen Sun
    Jikui Wang
    Guosong Chen
    Microchimica Acta, 2018, 185
  • [4] A nickel nanoparticle/nafion-graphene oxide modified screen-printed electrode for amperometric determination of chemical oxygen demand
    Zhang, Baojian
    Huang, Liming
    Tang, Meihua
    Hunter, Kenneth W.
    Feng, Yan
    Sun, Qianwen
    Wang, Jikui
    Chen, Guosong
    MICROCHIMICA ACTA, 2018, 185 (08)
  • [5] Fabrication of graphene/gold-modified screen-printed electrode for detection of carcinoembryonic antigen
    Chan, K. F.
    Lim, H. N.
    Shams, N.
    Jayabal, S.
    Pandikumar, A.
    Huang, N. M.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 666 - 674
  • [6] A Copper Oxide Nanoparticle Modified Screen-printed Electrode for Determination of Mirtazapine
    El-Shal, Manal A.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2019, 62 (09): : 1739 - 1748
  • [7] Sensitive and Selective Sensing of Hydrogen Peroxide with Iron-Tetrasulfophthalocyanine-Graphene-Nafion Modified Screen-Printed Electrode
    Zhu, Mingfang
    Li, Nan
    Ye, Jianshan
    ELECTROANALYSIS, 2012, 24 (05) : 1212 - 1219
  • [8] A Novel Screen-Printed Electrode Modified by graphene Nanocomposite for Detecting Clozapine
    Beitollahi, Hadi
    Tajik, Somayeh
    Aflatoonian, Mohammad Reza
    Nejad, Fariba Garkani
    Zhang, Kaiqiang
    Asl, Mehdi Shahedi
    Quyet Van Le
    Cha, Joo Hwan
    Shokouhimehr, Mohammadreza
    Peng, Wanxi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 9271 - 9281
  • [9] SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACYANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION
    Mattos, I. L.
    Padilla, F.
    Zagal, J. H.
    Falcao, E. H. L.
    Segura, R.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2011, 56 (03): : 803 - 807
  • [10] Electrochemical determination of synephrine by using nafion/UiO-66/ graphene-modified screen-printed carbon electrode
    Zhang, Yi
    You, Zongyi
    Liu, Liangliang
    Duan, Shengwen
    Xiao, Aiping
    CURRENT RESEARCH IN FOOD SCIENCE, 2022, 5 : 1158 - 1166