Effect of accelerated electron beam on mechanical properties of human cortical bone: influence of different processing methods

被引:19
|
作者
Kaminski, Artur [1 ,2 ,3 ]
Grazka, Ewelina [3 ]
Jastrzebska, Anna [3 ]
Marowska, Joanna [3 ]
Gut, Grzegorz [1 ,2 ,3 ]
Wojciechowski, Artur [4 ]
Uhrynowska-Tyszkiewicz, Izabela [1 ,2 ,3 ]
机构
[1] Med Univ Warsaw, Dept Transplantol, PL-02004 Warsaw, Poland
[2] Med Univ Warsaw, Cent Tissue Bank, PL-02004 Warsaw, Poland
[3] Natl Ctr Tissue & Cell Banking, Warsaw, Poland
[4] Med Univ Warsaw, Dept Clin Radiol 1, PL-02004 Warsaw, Poland
关键词
Human bone; Compact bone grafts; Electron beam irradiation; Mechanical properties; Compression test; HUMAN CANCELLOUS BONE; GAMMA-IRRADIATION; STRENGTH MEASUREMENT; ALLOGRAFT BONE; FRESH-FROZEN; RADIATION; COLLAGEN; STERILIZATION; GRAFTS;
D O I
10.1007/s10561-012-9312-6
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Accelerated electron beam (EB) irradiation has been a sufficient method used for sterilisation of human tissue grafts for many years in a number of tissue banks. Accelerated EB, in contrast to more often used gamma photons, is a form of ionizing radiation that is characterized by lower penetration, however it is more effective in producing ionisation and to reach the same level of sterility, the exposition time of irradiated product is shorter. There are several factors, including dose and temperature of irradiation, processing conditions, as well as source of irradiation that may influence mechanical properties of a bone graft. The purpose of this study was to evaluate the effect e-beam irradiation with doses of 25 or 35 kGy, performed on dry ice or at ambient temperature, on mechanical properties of non-defatted or defatted compact bone grafts. Left and right femurs from six male cadaveric donors, aged from 46 to 54 years, were transversely cut into slices of 10 mm height, parallel to the longitudinal axis of the bone. Compact bone rings were assigned to the eight experimental groups according to the different processing method (defatted or non-defatted), as well as e-beam irradiation dose (25 or 35 kGy) and temperature conditions of irradiation (ambient temperature or dry ice). Axial compression testing was performed with a material testing machine. Results obtained for elastic and plastic regions of stress-strain curves examined by univariate analysis are described. Based on multivariate analysis, including all groups, it was found that temperature of e-beam irradiation and defatting had no consistent significant effect on evaluated mechanical parameters of compact bone rings. In contrast, irradiation with both doses significantly decreased the ultimate strain and its derivative toughness, while not affecting the ultimate stress (bone strength). As no deterioration of mechanical properties was observed in the elastic region, the reduction of the energy absorption capacity of irradiated bone rings apparently resulted from changes generated by irradiation within the plastic strain region.
引用
收藏
页码:375 / 386
页数:12
相关论文
共 50 条
  • [1] Effect of accelerated electron beam on mechanical properties of human cortical bone: influence of different processing methods
    Artur Kaminski
    Ewelina Grazka
    Anna Jastrzebska
    Joanna Marowska
    Grzegorz Gut
    Artur Wojciechowski
    Izabela Uhrynowska-Tyszkiewicz
    Cell and Tissue Banking, 2012, 13 : 375 - 386
  • [2] Effect of gamma irradiation on mechanical properties of human cortical bone: influence of different processing methods
    Kaminski, Artur
    Jastrzebska, Anna
    Grazka, Ewelina
    Marowska, Joanna
    Gut, Grzegorz
    Wojciechowski, Artur
    Uhrynowska-Tyszkiewicz, Izabela
    CELL AND TISSUE BANKING, 2012, 13 (03) : 363 - 374
  • [3] Effect of gamma irradiation on mechanical properties of human cortical bone: influence of different processing methods
    Artur Kaminski
    Anna Jastrzebska
    Ewelina Grazka
    Joanna Marowska
    Grzegorz Gut
    Artur Wojciechowski
    Izabela Uhrynowska-Tyszkiewicz
    Cell and Tissue Banking, 2012, 13 : 363 - 374
  • [4] Effect of different sterilization processing methods on the mechanical properties of human cancellous bone allografts
    Vastel, L
    Meunier, A
    Siney, H
    Sedel, L
    Courpied, JP
    BIOMATERIALS, 2004, 25 (11) : 2105 - 2110
  • [5] Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone
    Stefan, Unger
    Michael, Blauth
    Werner, Schmoelz
    BONE, 2010, 47 (06) : 1048 - 1053
  • [6] Effect of different thermomechanical processing on structure and mechanical properties of electron beam melted niobium
    M. Sankar
    Y. Satish Reddy
    R. G. Baligidad
    Transactions of the Indian Institute of Metals, 2009, 62 : 135 - 139
  • [7] Effect of different thermomechanical processing on structure and mechanical properties of electron beam melted niobium
    Sankar, M.
    Reddy, Y. Satish
    Baligidad, R. G.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2009, 62 (02): : 135 - 139
  • [8] Effect of age on mechanical properties of the collagen phase in different orientations of human cortical bone
    Leng, Huijie
    Reyes, Michael J.
    Dong, Xuanliang N.
    Wang, Xiaodu
    BONE, 2013, 55 (02) : 288 - 291
  • [9] The effect of strain rate on the mechanical properties of human cortical bone
    Hansen, Ulrich
    Zioupos, Peter
    Simpson, Rebecca
    Currey, John D.
    Hynd, David
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (01):
  • [10] Influence of anthopometric variables on the mechanical properties of human rib cortical bone
    Velazquez-Ameijide, Juan
    Garcia-Vilana, Silvia
    Sanchez-Molina, David
    Martinez-Gonzalez, Eva
    Lluma, Jordi
    Rebollo-Soria, M. Carmen
    Arregui-Dalmases, Carlos
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (03)