Frameless set-up with ExacTrac® system for stereotactic radiotherapy of brain metastasis: Descriptive study from five French centres

被引:2
|
作者
Ohnleiter, T. [1 ]
Mahe, M. -A. [2 ]
Biau, J. [3 ]
Wdowczyk, D. [4 ]
Clavier, J. -B. [1 ]
Antoni, D. [1 ,5 ]
Noel, G. [1 ,5 ]
机构
[1] Ctr Lutte Canc Paul Strauss, Dept Radiotherapie, 3 Rue Porte Hop, F-67065 Strasbourg, France
[2] Inst Cancerol Ouest Rene Gauducheau, Dept Radiotherapie, Blvd Jacques Monod, F-44805 St Herblain, France
[3] Ctr Jean Perrin, Dept Radiotherapie, 58 Rue Montalembert, F-63000 Clermont Ferrand, France
[4] Inst Canc Courlancy, Dept Radiotherapie, 38 Rue Courlancy, F-51100 Reims, France
[5] Univ Strasbourg, FMTS, Lab EA 3430, F-67000 Strasbourg, France
来源
CANCER RADIOTHERAPIE | 2016年 / 20卷 / 08期
关键词
Stereotactic irradiation; Brain metastasis; Frameless; ExacTrac (R); Novalis (R); RADIOSURGERY; ACCURACY;
D O I
10.1016/j.canrad.2016.04.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - This study aimed to analyse the positioning protocols with the ExacTrac (R) system, associated with a dedicated linear accelerator such as Novalis (R), for stereotactic treatment of brain metastases in several French centres. Materials and methods. - A survey, including three questions about the prescription of irradiation and twenty-one questions about how the ExacTrac (R) system is used, was sent to nine French centres owning a dedicated Novalis (R) accelerator. Five centres have accepted to participate in the study. Results. - All centres checked the positioning before each treatment's bow, with residual mismatch tolerances of 0.5 to 0.7 mm for the translations and 0.5 to 1 degrees for the rotations. All centres except one also realised orthogonal planar images of classic incidences to help operators ensure proper isocentre positioning. Prescribed doses were 20 Gy in one fraction, 30 Gy and 33 Gy in three fractions or 34 Gy in four fractions, mainly depending on the size of the lesion. Finally, a physician validated the images at the treatment station before starting the irradiation. Conclusions. - The practices of the different centres concerning the positioning protocols were rather homogeneous, in agreement with the literature data on ExacTrac (R) system's accuracy, as well as proposed fractionations. The systematic medical validation at the treatment station may, however, be questioned because of the waiting time between the doctor's call and validation itself and because of its usefulness; indeed, corrections by the radiation oncologist are very rare and in some centres, non-existent. (C) 2016 Published by Elsevier Masson SAS on behalf of Societe frangaise de radiotherapie oncologique (SFRO).
引用
收藏
页码:768 / 775
页数:8
相关论文
共 14 条
  • [1] SET-UP ERRORS IN HEAD-AND-NECK FRAMELESS STEREOTACTIC TREATMENTS: AN INVESTIGATION USING EXACTRAC
    Uttman, K.
    Jarlskog, C. Zacharatou
    Enmark, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S268 - S268
  • [2] Set-up errors in body stereotactic treatments detected by the ExacTrac system
    Tagaste, B
    Garibaldi, C
    Catalano, G
    Cambria, R
    Cattani, F
    Baroni, G
    Morra, A
    Alterio, D
    Tosi, G
    Orecchia, R
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S391 - S391
  • [3] Calculation of set-up margin in frameless stereotactic radiotherapy accounting for translational and rotational patient positing error
    Manikandan, Arjunan
    Sarkar, Biplab
    Munshi, Anusheel
    Krishnankutty, Saneg
    Ganesh, Tharmarnadar
    Mohanti, Bidhu Kalyan
    Manikandan, Sujatha
    Anirudh, Pradhan
    Chandrasekharan, Surekha
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (02) : 169 - 176
  • [4] Study of the Positioning Accuracy of the BrainLab Mask for Frameless Stereotactic Head Radiotherapy Using the ExacTrac IGRT System
    Granero, D.
    Rosello, J.
    Vicedo, A.
    Brualla, L.
    Garcia-Hernandez, T.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Initial clinical experience with exactrac automated X-ray fusion to assess patient set-up and immobilization with the brainlab mask/frame system in stereotactic radiotherapy of the brain
    Figler, B
    Mahadevan, A
    Suh, J
    Djemil, T
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S497 - S498
  • [6] Hypofractionated stereotactic body radiotherapy for thoracic lesions: A comparison between frame DRR-PV guided and frameless cone beam guided set-up
    Ursino, S.
    Fiorica, F.
    Lappi, S.
    Fabbri, S.
    Flammia, C.
    Perazzini, L.
    De Guglielmo, E.
    Vignoli, L.
    Cartei, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S652 - S653
  • [7] Rotational positional error-corrected linear set-up margin calculation technique for lung stereotactic body radiotherapy in a dual imaging environment of 4-D cone beam CT and ExacTrac stereoscopic imaging
    Sarkar, Biplab
    Ganesh, Tharmarnadar
    Munshi, Anusheel
    Manikandan, Arjunan
    Roy, Soumya
    Krishnankutty, Saneg
    Chitral, Latika
    Sathiya, Jean
    Pradhan, Anirudh
    Mohanti, Bidhu Kalyan
    [J]. RADIOLOGIA MEDICA, 2021, 126 (07): : 979 - 988
  • [8] Rotational positional error-corrected linear set-up margin calculation technique for lung stereotactic body radiotherapy in a dual imaging environment of 4-D cone beam CT and ExacTrac stereoscopic imaging
    Biplab Sarkar
    Tharmarnadar Ganesh
    Anusheel Munshi
    Arjunan Manikandan
    Soumya Roy
    Saneg Krishnankutty
    Latika Chitral
    Jean Sathiya
    Anirudh Pradhan
    Bidhu Kalyan Mohanti
    [J]. La radiologia medica, 2021, 126 : 979 - 988
  • [9] Evaluation of the detection accuracy of set-up for various treatment sites using surface-guided radiotherapy system, VOXELAN: a phantom study
    Saito, Masahide
    Ueda, Koji
    Suzuki, Hidekazu
    Komiyama, Takafumi
    Marino, Kan
    Aoki, Shinichi
    Sano, Naoki
    Onishi, Hiroshi
    [J]. JOURNAL OF RADIATION RESEARCH, 2022, 63 (03) : 435 - 442
  • [10] A Protocol to Investigate Deep Brain Stimulation for Refractory Tinnitus: From Rat Model to the Set-Up of a Human Pilot Study
    van Zwieten, Gusta
    Devos, Jana V. P.
    Kotz, Sonja A.
    Ackermans, Linda
    Brinkmann, Pia
    Dauven, Lobke
    George, Erwin L. J.
    Janssen, A. Miranda L.
    Kremer, Bernd
    Leue, Carsten
    Schwartze, Michael
    Temel, Yasin
    Smit, Jasper V.
    Janssen, Marcus L. F.
    [J]. AUDIOLOGY RESEARCH, 2023, 13 (01) : 49 - 63