Improved correction for gradient nonlinearity effects in diffusion-weighted imaging

被引:67
|
作者
Tan, Ek T. [1 ]
Marinelli, Luca [1 ]
Slavens, Zachary W. [2 ]
King, Kevin F. [2 ]
Hardy, Christopher J. [1 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI USA
关键词
gradient nonlinearity; diffusion weighted imaging; cancer imaging; TREATMENT RESPONSE; FIELD DISTORTIONS; MRI; CANCER; COEFFICIENT; BIOMARKER; THERAPY; ECHO;
D O I
10.1002/jmri.23942
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide an improved correction for gradient nonlinearity (GN) effects in diffusion-weighted imaging (DWI). These effects produce spatially varying apparent diffusion coefficient (ADC), a result that will be significant in large field-of-view imaging, and may be confounded by distortion and concomitant fields related to the DWI acquisition. Materials and Methods: The effect of more accurate gradient field maps on GN correction (GNC) of ADC was evaluated. A simulation compared GN effects in commonly imaged anatomy. A temperature-controlled phantom was imaged at positions 0 cm and 11 cm from isocenter and in two whole-body MRI systems at 1.5T with different patient bore diameters (55 cm and 60 cm). Varying correction methods were applied to determine the errors from spatial variance and interscanner reproducibility. Results: As compared to conventional fifth-order spherical harmonics, a seventh-order GNC improved ADC accuracy by 1%. The combination of GNC with a dual-spin-echo pulse sequence and a retrospective concomitant field correction reduced ADC error due to spatial variance from 9.5% to 1.8% (55 cm bore) and from 4.2% to 1.8% (60 cm bore). The error in ADC attributed to interscanner reproducibility was reduced from 5.8% to 0.15% (at isocenter) and from 10% to 0.63% (11 cm from isocenter). Conclusion: GNC in DWI improved spatial accuracy and interscanner reproducibility of ADC. J. Magn. Reson. Imaging 2013;38:448-453. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 50 条
  • [1] Diffusion-Weighted Imaging of the Abdomen: Correction for Gradient Nonlinearity Bias in Apparent Diffusion Coefficient
    Wang, Jian
    Ma, Chao
    Yang, Panpan
    Wang, Zhen
    Chen, Yufei
    Bian, Yun
    Shao, Chengwei
    Lu, Jianping
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 223 - 231
  • [2] QIN DAWG Validation of Gradient Nonlinearity Bias Correction Workflow for Quantitative Diffusion-Weighted Imaging in Multicenter Trials
    Malyarenko, Dariya I.
    Wilmes, Lisa J.
    Arlinghaus, Lori R.
    Jacobs, Michael A.
    Huang, Wei
    Helmer, Karl G.
    Taouli, Bachir
    Yankeelov, Thomas E.
    Newitt, David
    Chenevert, Thomas L.
    [J]. TOMOGRAPHY, 2016, 2 (04) : 396 - 405
  • [3] Editorial for "Diffusion Weighted Imaging of the Abdomen: Correction for Gradient Nonlinearity Bias in Apparent Diffusion Coefficient"
    Li, Weiguo
    Mouli, Samdeep K.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 232 - 233
  • [4] Efficient approximate signal reconstruction for correction of gradient nonlinearities in diffusion-weighted imaging
    Kanakaraj, Praitayini
    Cai, Leon Y.
    Yao, Tianyuan
    Rheault, Francois
    Rogers, Baxter P.
    Anderson, Adam
    Schilling, Kurt G.
    Landman, Bennett A.
    [J]. MAGNETIC RESONANCE IMAGING, 2023, 102 : 20 - 25
  • [5] Diffusion tensor imaging with multiple diffusion-weighted gradient directions
    Jiang, Shan
    Liu, Meixia
    Han, Tong
    Liu, Weihua
    [J]. NEURAL REGENERATION RESEARCH, 2011, 6 (01) : 66 - 71
  • [7] Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging
    Bammer, R
    Markl, M
    Barnett, A
    Acar, B
    Alley, MT
    Pelc, NJ
    Glover, GH
    Moseley, ME
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (03) : 560 - 569
  • [8] Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity
    Bodammer, N
    Kaufmann, J
    Kanowski, M
    Tempelmann, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 188 - 193
  • [9] Diffusion-weighted imaging
    Rovaris, M.
    Perego, E.
    Filippi, M.
    [J]. NEURODEGENERATION IN MULTIPLE SCLEROSIS, 2007, : 65 - +
  • [10] Diffusion-weighted imaging
    Zimmerman, RA
    [J]. CRITICAL REVIEWS IN NEUROSURGERY, 1997, 7 (04) : 221 - 227