Timed Up and Go Tests in Cardiac Rehabilitation RELIABILITY AND COMPARISON WITH THE 6-MINUTE WALK TEST

被引:23
|
作者
Bellet, R. Nicole [1 ]
Francis, Rebecca L. [2 ]
Jacob, Justin S. [1 ,2 ]
Healy, Karen M. [2 ]
Bartlett, Harold J. [3 ,4 ]
Adams, Lewis [5 ,6 ]
Morris, Norman R. [5 ,6 ]
机构
[1] Prince Charles Hosp, Physiotherapy Dept, Brisbane, Qld 4032, Australia
[2] Chermside Adult Community Hlth Ctr, Cardiac Rehabil & Prevent Program, Brisbane, Qld, Australia
[3] Prince Charles Hosp, Brisbane, Qld 4032, Australia
[4] Queensland Univ Technol, Discipline Math Sci, Brisbane, Qld 4001, Australia
[5] Griffith Univ, Sch Physiotherapy & Exercise Sci, Southport, Qld 4215, Australia
[6] Griffith Univ, Griffith Hlth Inst, Southport, Qld 4215, Australia
关键词
cardiac; exercise therapy; outcome assessment; rehabilitation; BONE-MINERAL DENSITY; EXERCISE PROGRAM; TRAINING-PROGRAM; FUNCTIONAL ABILITY; PHYSICAL-ACTIVITY; ELDERLY-WOMEN; OLDER-PEOPLE; BALANCE; STRENGTH; FALLS;
D O I
10.1097/HCR.0b013e3182773fae
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PURPOSE: To test the reliability of Timed Up and Go Tests (TUGTs) in cardiac rehabilitation (CR) and compare TUGTs to the 6-Minute Walk Test (6MWT) for outcome measurement. METHODS: Sixty-one of 154 consecutive community-based CR patients were prospectively recruited. Subjects undertook repeated TUGTs and 6MWTs at the start of CR (start-CR), postdischarge from CR (post-CR), and 6 months postdischarge from CR (6 months post-CR). The main outcome measurements were TUGT time (TUGTT) and 6MWT distance (6MWD). RESULTS: Mean (SD) TUGTT1 and TUGTT2 at the 3 assessments were 6.29 (1.30) and 5.94 (1.20); 5.81 (1.22) and 5.53 (1.09); and 5.39 (1.60) and 5.01 (1.28) seconds, respectively. A reduction in TUGTT occurred between each outcome point (P <= .002). Repeated TUGTTs were strongly correlated at each assessment, intraclass correlation (95% CI) = 0.85 (0.76-0.91), 0.84 (0.73-0.91), and 0.90 (0.83-0.94), despite a reduction between TUGTT1 and TUGTT2 of 5%, 5%, and 7%, respectively (P <= .006). Relative decreases in TUGTT1 (TUGTT2) occurred from start-CR to post-CR and from start-CR to 6 months postCR of -7.5% (-6.9%) and -14.2% (-15.5%), respectively, while relative increases in 6MWD1 (6MWD2) occurred, 5.1% (7.2%) and 8.4% (10.2%), respectively (P < .001 in all cases). Pearson correlation coefficients for 6MWD1 to TUGTT1 and TUGTT2 across all times were -0.60 and -0.68 (P < .001) and the intraclass correlations (95% CI) for the speeds derived from averaged 6MWDs and TUGTTs were 0.65 (0.54, 0.73) (P < .001). CONCLUSIONS: Similar relative changes occurred for the TUGT and the 6MWT in CR. A significant correlation between the TUGTT and 6MWD was demonstrated, and we suggest that the TUGT may provide a related or a supplementary measurement of functional capacity in CR.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 50 条
  • [1] Comparing the Physiological Responses to the 6-Minute Walk Test, Timed Up and Go Test, and Treadmill Cardiopulmonary Exercise Test
    Alves, Eduardo S.
    Bellet, R. Nicole
    Sharma, Pramod
    Balmain, Bryce N.
    Aitken, Craig
    Doering, Thomas
    Orola, Leilani
    Green, Anita
    Paim, Tatiana
    O'Connor, Fergus
    Morris, Norman R.
    REHABILITATION RESEARCH AND PRACTICE, 2024, 2024
  • [2] Reliability of the 6-minute walk test in patients referred for pulmonary rehabilitation
    van der Schoot, H. J. M.
    van Ranst, D.
    Otten, H. J.
    Stoop, W. A.
    van de Port, I. G.
    Meijer, J. W.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [3] The 6-minute walk test in outpatient cardiac rehabilitation: validity, reliability and responsiveness-a systematic review
    Bellet, R. Nicole
    Adams, Lewis
    Morris, Norman R.
    PHYSIOTHERAPY, 2012, 98 (04) : 277 - 287
  • [4] Reliability and Validity of the 6-Minute Walk Test in Hypophosphatasia
    Phillips, Dawn
    Tomazos, Ioannis C.
    Moseley, Scott
    L'Italien, Gil
    Gomes da Silva, Hugo
    Lerma Lara, Sergio
    JBMR PLUS, 2019, 3 (06)
  • [5] The relationship between "timed-up and go test" and "6-minute walk test" in assessing functional capacity of adult hemophilic individuals
    Aykar, S. Onal
    Can, F.
    Aksu, S.
    Sahin, F.
    HAEMOPHILIA, 2019, 25 : 171 - 171
  • [6] Rehabilitation and 6-Minute Walk Test After Liver Transplantation
    Foroncewicz, B.
    Mucha, K.
    Szparaga, B.
    Raczynska, J.
    Ciszek, M.
    Pilecki, T.
    Krawczyk, M.
    Paczek, L.
    TRANSPLANTATION PROCEEDINGS, 2011, 43 (08) : 3021 - 3024
  • [7] Cardiac Rehabilitation Increases the Reliability of the 6-Minute Walk Test in Patients After Coronary Artery Bypass Graft Surgery
    Hayta, Emruallah
    Korkmaz, Ozge
    HEART SURGERY FORUM, 2017, 20 (06): : E247 - E251
  • [8] Two-minute versus 6-minute walk distances during 6-minute walk test in neuromuscular disease: Is the 2-minute walk test an effective alternative to a 6-minute walk test?
    Witherspoon, J. W.
    Vasavada, R.
    Logaraj, R. H.
    Waite, M.
    Collins, J.
    Shieh, C.
    Meilleur, K.
    Bonnemann, C.
    Jain, M.
    EUROPEAN JOURNAL OF PAEDIATRIC NEUROLOGY, 2019, 23 (01) : 165 - 170
  • [9] Using a treadmill for the 6-minute walk test - Reliability and validity
    Laskin, James J.
    Bundy, Sadie
    Marron, Hanna
    Moore, Holly
    Swanson, Melissa
    Blair, Molly
    Humphrey, Reed
    JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2007, 27 (06) : 407 - 410
  • [10] Reliability Of The 6-minute Walk Test In Adults With Intellectual Disabilities
    Guerra, Miriam
    Oviedo, Guillermo
    Javierre, Casimiro
    Carmen Delicado, Ma
    Soto, Carlos
    Carbo, Maria
    Fernhall, Bo
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 74 - 75