An integrated PCR microfluidic chip incorporating aseptic electrochemical cell lysis and capillary electrophoresis amperometric DNA detection for rapid and quantitative genetic analysis

被引:49
|
作者
Jha, Sandeep Kumar [1 ]
Chand, Rohit [1 ]
Han, Dawoon [1 ]
Jang, You-Cheol [1 ]
Ra, Gyu-Sik [1 ]
Kim, Joung Sug [2 ]
Nahm, Baek-Hie [2 ]
Kim, Yong-Sang [1 ,3 ]
机构
[1] Myongji Univ, Dept Nanosci & Engn, Yongin, Gyeonggi, South Korea
[2] Myongji Univ, Div Biosci & Bioinformat, Yongin, Gyeonggi, South Korea
[3] Myongji Univ, Dept Elect Engn, Yongin, Gyeonggi, South Korea
关键词
AMPLIFICATION; MICROCHIP; SYSTEM; DEVICES; GLASS;
D O I
10.1039/c2lc40727b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully integrated microchip for performing cell lysis, polymerase chain reaction (PCR) and quantitative analysis of DNA amplicons in a single step is described herein. The chip was built on glass substrate using an indium-tin-oxide (ITO) microheater and PDMS engraved microchannels, which integrated an electrochemical cell lysis zone, a continuous flow PCR module and capillary electrophoresis amperometric detection (CE-AD) system. The total length of the microchannel was 4625 mm for performing 25 cycles of flow-through PCR and was laid on a handheld form factor of 96 x 96 mm(2) area. The key to the fabrication of such a device lies in the use of a single medium to carry out different kinds of biochemical reactions and hence, a reagentless electrochemical cell lysis protocol was integrated on the microchip which was capable of lysing most cell types, including difficult to lyse gram positive bacteria. The lysate contained genomic DNA from a sample which was proven to be suitable for PCR reactions. Genetic analysis was successfully performed on the microchip with purified lambda phage genomic DNA and various cell types, including nontumorigenic MCF-10A and tumorigenic MCF-7 human cell lines, gram negative bacteria Escherichia coli O157:H7, and gram positive bacteria Bacillus subtilis, at an optimized flow rate of 5 mu l min(-1). For the detection of amplicon DNA, a CE-AD system was used, with semisolid alkaline agarose within the capillary microchannel to minimize interference from cell debris and for efficient resolution of DNA fragments. High signal to noise ratio during amperometric detection and the use of online FFT filtering protocol enhanced the limit of detection of DNA amplicons. Therefore, with a combination of portability, cost-effectiveness and performance, the proposed integrated PCR microchip can be used for one step genetic analysis of most of the cell types and will enable more accessible healthcare.
引用
收藏
页码:4455 / 4464
页数:10
相关论文
共 18 条
  • [1] Integrated microfluidic chip for rapid DNA digestion and time-resolved capillary electrophoresis analysis
    Lin, Che-Hsin
    Wang, Yao-Nan
    Fu, Lung-Ming
    BIOMICROFLUIDICS, 2012, 6 (01):
  • [2] Detection of Periodontal Pathogens Based on an Integrated Continuous Flow PCR and Capillary Electrophoresis Microfluidic Chip
    Yang, Bo
    Huang, Jiaxin
    Tao, Chunxian
    Li, Zhenqing
    Zhang, Dawei
    Yamaguchi, Yoshinori
    SEPARATIONS, 2023, 10 (04)
  • [3] On-chip quantitative PCR using integrated real-time detection by capillary electrophoresis
    Liu, Yu
    Li, Chen
    Li, Zhi
    Chan, Samuel D.
    Eto, Daisuke
    Wu, Warren
    Zhang, Jian Ping
    Chien, Ring-Ling
    Wada, Henry G.
    Greenstein, Michael
    Satomura, Shinji
    ELECTROPHORESIS, 2016, 37 (03) : 545 - 552
  • [4] Rapid detection for primary screening of influenza A virus: microfluidic RT-PCR chip and electrochemical DNA sensor
    Yamanaka, Keiichiro
    Saito, Masato
    Kondoh, Kenji
    Hossain, Mohammad Mosharraf
    Koketsu, Ritsuko
    Sasaki, Tadahiro
    Nagatani, Naoki
    Ikuta, Kazuyoshi
    Tamiya, Eiichi
    ANALYST, 2011, 136 (10) : 2064 - 2068
  • [5] Quantitative analysis of cytokeratin 20 gene expression using RT-PCR and capillary electrophoresis with fluorescent DNA detection
    van Eekelen, JAM
    Shammas, FV
    Wee, L
    Heikkilä, R
    Osland, A
    CLINICAL BIOCHEMISTRY, 2000, 33 (06) : 457 - 464
  • [6] Quantitative analysis of chimerism after allogeneic stem cell transplantation by PCR amplification of microsatellite markers and capillary electrophoresis with fluorescence detection: the Vienna experience
    Schraml, E
    Daxberger, H
    Watzinger, F
    Lion, T
    LEUKEMIA, 2003, 17 (01) : 224 - 227
  • [7] Quantitative analysis of chimerism after allogeneic stem cell transplantation by PCR amplification of microsatellite markers and capillary electrophoresis with fluorescence detection: the Tuebingen experience
    H Kreyenberg
    W Hölle
    S Möhrle
    D Niethammer
    P Bader
    Leukemia, 2003, 17 : 237 - 240
  • [8] Quantitative analysis of chimerism after allogeneic stem cell transplantation by PCR amplification of microsatellite markers and capillary electrophoresis with fluorescence detection: the Frankfurt experience
    Koehl, U
    Beck, O
    Esser, R
    Seifried, E
    Klingebiel, T
    Schwabe, D
    Seidl, C
    LEUKEMIA, 2003, 17 (01) : 232 - 236
  • [10] Quantitative analysis of chimerism after allogeneic stem cell transplantation by PCR amplification of microsatellite markers and capillary electrophoresis with fluorescence detection: the Vienna experience
    E Schraml
    H Daxberger
    F Watzinger
    T Lion
    Leukemia, 2003, 17 : 224 - 227