Toward Fully Automated Multicriterial Plan Generation: A Prospective Clinical Study

被引:126
|
作者
Voet, Peter W. J. [1 ]
Dirkx, Maarten L. P. [1 ]
Breedveld, Sebastiaan [1 ]
Fransen, Dennie [1 ]
Levendag, Peter C. [1 ]
Heijmen, Ben J. M. [1 ]
机构
[1] Dr Daniel den Hoed Canc Ctr, Dept Radiat Oncol, Erasmus Med Ctr, NL-3075 EA Rotterdam, Netherlands
关键词
INTENSITY-MODULATED RADIOTHERAPY; OPTIMIZATION; IMRT; CANCER;
D O I
10.1016/j.ijrobp.2012.04.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To prospectively compare plans generated with iCycle, an in-house-developed algorithm for fully automated multicriterial intensity modulated radiation therapy (IMRT) beam profile and beam orientation optimization, with plans manually generated by dosimetrists using the clinical treatment planning system. Methods and Materials: For 20 randomly selected head-and-neck cancer patients with various tumor locations (of whom 13 received sequential boost treatments), we offered the treating physician the choice between an automatically generated iCycle plan and a manually optimized plan using standard clinical procedures. Although iCycle used a fixed "wish list" with hard constraints and prioritized objectives, the dosimetrists manually selected the beam configuration and fine tuned the constraints and objectives for each IMRT plan. Dosimetrists were not informed in advance whether a competing iCycle plan was made. The 2 plans were simultaneously presented to the physician, who then selected the plan to be used for treatment. For the patient group, differences in planning target volume coverage and sparing of critical tissues were quantified. Results: In 32 of 33 plan comparisons, the physician selected the iCycle plan for treatment. This highly consistent preference for the automatically generated plans was mainly caused by the improved sparing for the large majority of critical structures. With iCycle, the normal tissue complication probabilities for the parotid and submandibular glands were reduced by 2.4% +/- 4.9% (maximum, 18.5%, P = .001) and 6.5% +/- 8.3% (maximum, 27%, P = .005), respectively. The reduction in the mean oral cavity dose was 2.8 +/- 2.8 Gy (maximum, 8.1 Gy, P = .005). For the swallowing muscles, the esophagus and larynx, the mean dose reduction was 3.3 +/- 1.1 Gy (maximum, 9.2 Gy, P < .001). For 15 of the 20 patients, target coverage was also improved. Conclusions: In 97% of cases, automatically generated plans were selected for treatment because of the superior quality. Apart from the improved plan quality, automatic plan generation is economically attractive because of the reduced workload. (c) 2013 Elsevier Inc.
引用
收藏
页码:866 / 872
页数:7
相关论文
共 50 条
  • [1] Towards Fully Automated Multi-Criterial Plan Generation: A Prospective Clinical Study
    Voet, P.
    Dirkx, M.
    Breedveld, S.
    Fransen, D.
    Levendag, P.
    Heijmen, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3848 - 3848
  • [2] Fully automated VMAT plan generation - an international multi-institutional validation study
    Heijmen, B.
    Voet, P.
    Fransen, D.
    Akhiat, H.
    Bonomo, P.
    Casati, M.
    Georg, D.
    Goldner, G.
    Henry, A.
    Lilley, J.
    Lohr, F.
    Marrazzo, L.
    Milder, M.
    Pallotta, S.
    Penninkhof, J.
    Seppenwoolde, Y.
    Simontacchi, G.
    Steil, V.
    Stieler, F.
    Wilson, S.
    Pellegrini, R.
    Breedveld, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S125 - S125
  • [3] Fully automated VMAT plan generation for prostate cancer patients
    Voet, P.
    Dirkx, M. L. P.
    Breedveld, S.
    Al Mamgani, A.
    Incrocci, L.
    Heijmen, B. J. M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S151 - S151
  • [4] Automated Multicriterial Plan Generation for Prostate Cancer Patients with Metal Hip Prostheses: Comparison of Planning Strategies
    Dirkx, M.
    Voet, P.
    Breedveld, S.
    Heijmen, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [5] A fast lexicographic optimizer for fully automated multi-objective plan generation
    Heijmen, B.
    Van Haveren, R.
    Voet, P.
    Breedveld, S.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S154 - S155
  • [6] Automated plan generation
    Breedveld, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S305 - S305
  • [7] Fully Automated Volumetric Modulated Arc Therapy Plan Generation for Prostate Cancer Patients
    Voet, Peter W. J.
    Dirkx, Maarten L. P.
    Breedveld, Sebastiaan
    Al-Mamgani, Abrahim
    Incrocci, Luca
    Heijmen, Ben J. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (05): : 1175 - 1179
  • [8] Fully automated treatment plan generation using Erasmus-iCycle - the Rotterdam experience
    Dirkx, M. L. P.
    Sharfo, A. W.
    Voet, P. W. J.
    Della Gala, G.
    Rossi, L.
    Fransen, D.
    Penninkhof, J. J.
    Hoogeman, M. S.
    Petit, S. F.
    Mendez-Romero, A. M.
    Mens, J. W.
    Incrocci, L.
    Hoekstra, N.
    Van de Pol, M.
    Aluwini, S.
    Breedveld, S.
    Heijmen, B. J. M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S145 - S145
  • [9] Fully Automated Multicriteria Optimization (MCO) Treatment Plan Generation for Radiation Treatment Planning
    Kirlik, G.
    D'Souza, W. D.
    Zhang, H. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S98 - S98
  • [10] Advances in automated plan generation
    Fox, Maria
    Thiebaux, Sylvie
    ARTIFICIAL INTELLIGENCE, 2009, 173 (5-6) : 501 - 502