Electrochemical immunosensor for simultaneous determination of interleukin-1 beta and tumor necrosis factor alpha in serum and saliva using dual screen printed electrodes modified with functionalized double walled carbon nanotubes

被引:101
|
作者
Sanchez-Tirado, E. [1 ]
Salvo, C. [1 ]
Gonzalez-Cortes, A. [1 ]
Yanez-Sedeno, P. [1 ]
Langa, F. [2 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, Ciudad Univ S-N, E-28040 Madrid, Spain
[2] Univ Castilla La Mancha, Inst Nanociencia Nanotecnol & Mat Mol INAMOL, Toledo 45071, Spain
关键词
Interleukin-1; beta; Tumor necrosis factor-alpha; Electrochemical immunosensor; Multiplex; Double-walled carbon nanotubes; Saliva; TNF-ALPHA; ULTRASENSITIVE DETECTION; SIGNAL AMPLIFICATION; MAGNETIC BEADS; LABEL; CYTOKINES; DISEASE; NANOPARTICLES; BIOMARKER; BIOASSAY;
D O I
10.1016/j.aca.2016.12.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual screen-printed carbon electrodes modified with 4-carboxyphenyl-functionalized double-walled carbon nanotubes (HOOC-Phe-DWCNTs/SPCEs) have been used as scaffolds for the preparation of electrochemical immunosensors for the simultaneous determination of the cytokines Interleukin-1 beta (IL-1 beta) and factor necrosis tumor alpha (TNF-alpha). IL-1 beta Capture antibodies were immobilized onto HOOC-PheDWCNTs/SPCEs in an oriented form making using the commercial polymeric coating Mix&Go(TM). Sandwich type immunoassays with amperometric signal amplification through the use of poly-HRPstreptavidin conjugates and H2O2 as HRP substrate and hydroquinone as redox mediator were implemented. Upon optimization of the experimental variables affecting the immunosensor performance, the dual immunosensor allows ranges of linearity extending between 0.5 and 100 pg/mL and from 1 to 200 pg/mL for IL-1 beta and TNF-alpha, respectively, these ranges being adequate for the determination of the cytokines in clinical samples. The achieved limits of detection were 0.38 pg/mL (IL-1 beta) and 0.85 pg/mL (TNF-alpha). In addition, the dual immunosensor exhibits excellent reproducibility of the measurements, storage stability of the anti-IL-Phe-DWCNT5/SPCE and anti-TNF-Phe-DWCNTs/SPCE conjugates, and selectivity as well as negligible cross-talking. The dual immunosensor was applied to the simultaneous determination of IL-1 beta and TNF-alpha in human serum spiked at clinically relevant concentration levels and in real saliva samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 7 条
  • [1] Development of an electrochemical immunosensor to determine zearalenone in maize using carbon screen printed electrodes modified with multi-walled carbon nanotubes/polyethyleneimine dispersions
    Ivan Riberi, Walter
    Viviana Tarditto, Lorena
    Alicia Zon, Maria
    Javier Arevalo, Fernando
    Fernandez, Hector
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 : 1271 - 1277
  • [2] Electrochemical detection of 8-hydroxyguanine using screen-printed carbon electrodes modified with carboxy-functionalized multi-walled carbon nanotubes
    Jelicova, Marcela
    Metelka, Radovan
    Pejchal, Jaroslav
    Lierova, Anna
    Sinkorova, Zuzana
    MONATSHEFTE FUR CHEMIE, 2019, 150 (07): : 1187 - 1193
  • [3] Electrochemical detection of 8-hydroxyguanine using screen-printed carbon electrodes modified with carboxy-functionalized multi-walled carbon nanotubes
    Marcela Jeličová
    Radovan Metelka
    Jaroslav Pejchal
    Anna Lierová
    Zuzana Šinkorová
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 1187 - 1193
  • [4] Two kinds of electrochemical immunoassays for the tumor necrosis factor α in human serum using screen-printed graphite electrodes modified with poly(anthranilic acid)
    Mazloum-Ardakani, Mohammad
    Hosseinzadeh, Laleh
    Taleat, Zahra
    MICROCHIMICA ACTA, 2014, 181 (9-10) : 917 - 924
  • [5] Two kinds of electrochemical immunoassays for the tumor necrosis factor α in human serum using screen-printed graphite electrodes modified with poly(anthranilic acid)
    Mohammad Mazloum-Ardakani
    Laleh Hosseinzadeh
    Zahra Taleat
    Microchimica Acta, 2014, 181 : 917 - 924
  • [6] Multiplexed determination of human growth hormone and prolactin at a label free electrochemical immunosensor using dual carbon nanotube-screen printed electrodes modified with gold and PEDOT nanoparticles
    Serafin, V.
    Martinez-Garcia, G.
    Aguei, L.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    ANALYST, 2014, 139 (18) : 4556 - 4563
  • [7] Electrochemical immunosensor for the determination of insulin-like growth factor-1 using electrodes modified with carbon nanotubes-poly(pyrrole propionic acid) hybrids
    Serafin, V.
    Aguei, L.
    Yanez-Sedeno, P.
    Pingarron, J. M.
    BIOSENSORS & BIOELECTRONICS, 2014, 52 : 98 - 104