PET Imaging of cerebral astrocytoma with 13N-ammonia

被引:31
|
作者
Zhang, Xiangsong
Liang, Changhong
Chen, Weian
Zhou, Dong
机构
[1] Sun Yat Sen Univ, Dept Nucl Med, Affiliated Hosp 1, Guangzhou 510089, Peoples R China
[2] Guangdong Prov Peoples Hosp, Dept Nucl Med, Guangzhou, Peoples R China
[3] Guangdong Prov Peoples Hosp, Dept Radiol, Guangzhou, Peoples R China
[4] Guangdong Prov Peoples Hosp, Dept Neurosurg, Guangzhou, Peoples R China
关键词
astrocytoma; ammonia; nitrogen radioisotopes; PET;
D O I
10.1007/s11060-005-9069-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We performed this study in order to assess the clinical potential of N-13-ammonia PET in patients with cerebral astrocytoma. Methods: Dynamic N-13-ammonia PET was performed in 25 patients with suspected cerebral gliomas or recurrent cerebral astrocytomas ( 19 male and 6 female patients; age range 18 - 64 years) detected by MRI. The histopathological diagnoses were made for all cases either by biopsy or craniotomy, except for one patient with brain infarction and one patient with brain radiation necrosis confirmed by repeated MRI imaging. PET images were visually inspected, and the tumor-to-white matter count (T/W) ratios and the perfusion index ( PI) of the tumors were determined. Results: Six out of nine cases of low-grade gliomas were detected with N-13-ammonia PET, and three non-astrocytoma low-grade gliomas were not detected with N-13-ammonia PET. All 11 high-grade astrocytomas exhibited markedly increased uptake of N-13-ammonia. The five non-neoplastic lesions exhibited low uptake, low T/W ratios and low PI. The significant differences were observed between high-grade and low-grade gliomas with respect to both the T/W ratios and PI ( T/W ratios: 5.92 +/- 2.27, n=11 vs. 1.66 +/- 0.61, n= 9, P< 0.01; PI: 5.22 +/- 1.67, n= 11 vs. 1.60 +/- 0.54, n= 9, P< 0.01). There were the significant differences between the T/W ratios and PI in low-grade astrocytomas and that in non-neoplastic lesions (T/W ratios: 2.00 +/- 0.42, n= 6 vs. 0.97 +/- 0.11, n= 5, P< 0.01; PI: 1.89 +/- 0.37, n= 6 vs. 0.99 +/- 0.03, n= 5, P< 0.01). Conclusions: There is a substantial uptake of N-13-ammonia in cerebral astrocytomas. N-13-ammonia PET may enable differentiation between low- and high-grade astrocytomas, and has the potential to enable differentiation between low- grade astrocytomas and non-neoplastic lesions.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [1] PET Imaging of cerebral astrocytoma with 13N-ammonia
    Zhang Xiangsong
    Liang Changhong
    Chen Weian
    Zhou Dong
    [J]. Journal of Neuro-Oncology, 2006, 78 : 145 - 151
  • [2] Human 13N-ammonia PET studies: the importance of measuring 13N-ammonia metabolites in blood
    Keiding, Susanne
    Sorensen, Michael
    Munk, Ole Lajord
    Bender, Dirk
    [J]. METABOLIC BRAIN DISEASE, 2010, 25 (01) : 49 - 56
  • [3] Human 13N-ammonia PET studies: the importance of measuring 13N-ammonia metabolites in blood
    Susanne Keiding
    Michael Sørensen
    Ole Lajord Munk
    Dirk Bender
    [J]. Metabolic Brain Disease, 2010, 25 : 49 - 56
  • [4] HUMAN 13N-AMMONIA PET STUDIES: THE IMPORTANCE OF MEASURING 13N-AMMONIA METABOLITES IN BLOOD
    Sorensen, M.
    Keiding, S.
    Munk, O. L.
    Bender, D.
    [J]. JOURNAL OF HEPATOLOGY, 2010, 52 : S216 - S216
  • [5] New findings on cerebral ammonia uptake in HE using functional 13N-ammonia PET
    Michael Sørensen
    Susanne Keiding
    [J]. Metabolic Brain Disease, 2007, 22 : 277 - 284
  • [6] 13N-Ammonia PET and Cardiac Outcomes
    不详
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) : 32N - 33N
  • [7] New findings on cerebral ammonia uptake in HE using functional 13N-ammonia PET
    Sorensen, Michael
    Keiding, Susanne
    [J]. METABOLIC BRAIN DISEASE, 2007, 22 (3-4) : 277 - 284
  • [8] Dynamic 13N-ammonia PET:: A new imaging method to diagnose hypopituitarism
    Zhang, XS
    Yue, DC
    Yang, AW
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (01) : 44 - 47
  • [9] Myocardial perfusion imaging with 13N-Ammonia PET is a strong predictor for outcome
    Fiechter, Michael
    Gebhard, Catherine
    Ghadri, Jelena R.
    Fuchs, Tobias A.
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Herzog, Bernhard A.
    Altorfer, Ulrich
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (03) : 1023 - 1026
  • [10] 13N-Ammonia PET/MR myocardial stress perfusion imaging early experience
    Lau, Jeffrey
    Laforest, Richard
    Zheng, Jie
    Lesniak, Donna
    Priatna, Agus
    Gropler, Robert
    Woodard, Pamela
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55