Recombinant tissue plasminogen activator to declot dialysis fistulas

被引:0
|
作者
Boobes, Y
AlHassan, H
Neglen, P
Obeid, K
Denour, N
机构
关键词
hemodialysis; rt-PA; thrombolysis; vascular access;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background, Thrombosis is the most common complication of hemodialysis access, Few reports are available concerning the use of recombinant tissue plasminogen activator (rt-PA) to declot an arterio-venous (A-V) access, This report describes the use of rt-PA for this purpose in 17 A-V accesses, Methods, The rt-PA was infused manually using a small catheter directly into the A-V access in 10-mg doses at 1-2 hour intervals, to a maximum dose of 40 mg, The procedure was followed by angiography, through the same catheter, Results. One fistula could not be cannulated, and in three the lysis of the clot failed, The other 13 cases (3 fistulas, and 10 grafts 81%) had successful lysis with return of bruit and thrill, Most patients had dialysis the next day using the declotted A-V access, Angiogram detected stenosis in six patients and surgical revision was done 1-8 days after the treatment, In the other seven patients no organic lesions were found, and six of them have a functioning A-V access 50-395 days after the lysis, Only 10-20 mg of rt-PA was needed in 60% of the cases, No major complication occurred; minor local bleeding was noted in five patients (5/16, 31%), Conclusion, rt-PA can be considered safe, effective and fast for declotting thrombosed arteriovenous fistulas.
引用
收藏
页码:107 / 110
页数:4
相关论文
共 50 条
  • [1] Tissue plasminogen activator can effectively declot peritoneal dialysis catheters
    Sahani, MM
    Mukhtar, KN
    Boorgu, R
    Leehey, DJ
    Popli, S
    Ing, TS
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 36 (03) : 675 - 675
  • [2] Dialysis Catheters and Recombinant Tissue Plasminogen Activator REPLY
    Hemmelgarn, Brenda R.
    Lok, Charmaine E.
    Scott-Douglas, Nairne
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (18): : 1779 - 1780
  • [3] Prevention of Dialysis Catheter Malfunction with Recombinant Tissue Plasminogen Activator
    Hemmelgarn, Brenda R.
    Moist, Louise M.
    Lok, Charmaine E.
    Tonelli, Marcello
    Manns, Braden J.
    Holden, Rachel M.
    LeBlanc, Martine
    Faris, Peter
    Barre, Paul
    Zhang, Jianguo
    Scott-Douglas, Nairne
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (04): : 303 - 312
  • [4] THE USE OF TISSUE PLASMINOGEN-ACTIVATOR TO DECLOT ARTERIOVENOUS ACCESSES IN HEMODIALYSIS-PATIENTS
    AHMED, A
    SHAPIRO, WB
    PORUSH, JG
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (01) : 38 - 43
  • [5] Hypersensitivity reactions to recombinant tissue plasminogen activator
    Alakbarzade, Vafa
    O'Kane, Declan
    Pereira, Anthony C.
    PRACTICAL NEUROLOGY, 2020, 20 (01) : 75 - +
  • [6] STABILITY OF RECOMBINANT TISSUE PLASMINOGEN-ACTIVATOR
    JAFFE, GJ
    GREEN, GDJ
    ABRAMS, GW
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (01) : 90 - 91
  • [7] Anaphylactoid reaction to recombinant tissue plasminogen activator
    Krmpotic, Kristina R.
    Fernandes, Christopher M. B.
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2007, 14 (01) : 60 - 61
  • [8] STABILITY OF RECOMBINANT TISSUE-PLASMINOGEN ACTIVATOR
    KO, PC
    WAGNER, DG
    CUPPLES, HP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2217 - 2217
  • [9] Tissue plasminogen activator for occluded peritoneal dialysis catheter
    Sakarcan, A
    Stallworth, JR
    PEDIATRIC NEPHROLOGY, 2002, 17 (03) : 155 - 156
  • [10] Tissue plasminogen activator for blocked peritoneal dialysis catheters
    R. G. Krishnan
    N. E. Moghal
    Pediatric Nephrology, 2006, 21 : 300 - 300