Combined local impedance and contact force for radiofrequency ablation assessment

被引:37
|
作者
Garrott, Kara [1 ]
Laughner, Jacob [1 ]
Gutbrod, Sarah [1 ]
Sugrue, Alan [2 ]
Shuros, Allan [1 ]
Sulkin, Matt [1 ]
Yasin, Omar [2 ]
Bush, Jamie [1 ]
Pottinger, Nathan [1 ]
Meyers, Jason [3 ]
Kapa, Suraj [2 ]
机构
[1] Boston Sci Corp, St Paul, MN USA
[2] Mayo Clin, Dept Cardiovasc Med, Coll Med, 200 First St SW, Rochester, MN 55905 USA
[3] Iowa Heart Ctr, Heart Rhythm Ctr, W Des Moines, IA USA
关键词
Ablation; Contact force; Electroanatomic mapping; Impedance; Radiofrequency; CATHETER ABLATION; LESION FORMATION; TEMPERATURE; SAFETY; MODEL; SIZE; FLOW;
D O I
10.1016/j.hrthm.2020.03.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The combination of contact force (CF) and local impedance (LI) may improve tissue characterization and lesion prediction during radiofrequency (RF) ablation. OBJECTIVE The purpose of this study was to evaluate the utility of LI combined with CF in assessing RF ablation efficacy. METHODS An LI catheter with CF sensing was evaluated in swine (n = 11) and in vitro (n = 14). The relationship between LI and CF in different tissue types was evaluated in vivo. Discrete lesions were created in vitro and in vivo at a range of forces, powers, and durations. Finally, an intercaval line was created in 3 groups at 30 W: 30s, Delta 20 Omega, and Delta 30 Omega. In the Delta 20 Omega and Delta 30 Omega groups, the user ablated until a 20 or 30 Omega LI drop. In the 30s group, the user was blinded to LI. RESULTS In vivo, distinction in LI was found between the blood pool and the myocardium (blood pool: 122 +/- 7.02 Omega; perpendicular contact: 220 +/- 29 Omega; parallel contact: 207 +/- 31 Omega). LI drop correlated with lesion depth both in vitro (R = 0.84) and in vivo (R = 0.79), informing sufficient lesion creation (LI drop >20 Omega) and warning of excessive heating (LI drop >65 Omega). When creating an intercaval line, the total RF time was significantly reduced when using LI guidance (6.4 +/- 2 minutes in Delta 20 Omega and 8.1 +/- 1 minutes in Delta 30 Omega) compared with a standard 30-second workflow (18 +/- 7 minutes). Acute conduction block was achieved in all Delta 30 Omega and 30s lines. CONCLUSION The addition of LI to CF provides feedback on both electrical and mechanical loads. This provides information on tissue type and catheter-tissue coupling; provides feedback on whether volumetric tissue heating is inadequate, sufficient, or excessive; and reduces ablation time.
引用
收藏
页码:1371 / 1380
页数:10
相关论文
共 50 条
  • [1] Local impedance measurements during contact force-guided cavotricuspid isthmus ablation for predicting an effective radiofrequency ablation
    Sasaki, Takehito
    Nakamura, Kohki
    Minami, Kentaro
    Take, Yutaka
    Nakatani, Yosuke
    Miki, Yuko
    Goto, Koji
    Kaseno, Kenichi
    Yamashita, Eiji
    Koyama, Keiko
    Naito, Shigeto
    JOURNAL OF ARRHYTHMIA, 2022, 38 (02) : 245 - 252
  • [2] Combined contact force and local impedance dynamics during repeat atrial fibrillation catheter ablation
    Alken, Fares-Alexander
    Scherschel, Katharina
    Kahle, Ann-Kathrin
    Masjedi, Mustafa
    Meyer, Christian
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [3] Radiofrequency lesion formation prediction with contact force versus local impedance
    Issa, Ziad F.
    CURRENT OPINION IN CARDIOLOGY, 2024, 39 (01) : 6 - 14
  • [4] Higher contact force, energy setting, and impedance rise during radiofrequency ablation predicts charring: New insights from contact force-guided in vivo ablation
    Makimoto, Hisaki
    Metzner, Andreas
    Tilz, Roland Richard
    Lin, Tina
    Heeger, Christian-H
    Rillig, Andreas
    Mathew, Shibu
    Lemes, Christine
    Wissner, Erik
    Kuck, Karl-Heinz
    Ouyang, Feifan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (02) : 227 - 235
  • [5] Endocardial Versus Epicardial Ventricular Radiofrequency Ablation Utility of In Vivo Contact Force Assessment
    Sacher, Frederic
    Wright, Matthew
    Derval, Nicolas
    Denis, Arnaud
    Ramoul, Khaled
    Roten, Laurent
    Pascale, Patrizzio
    Bordachar, Pierre
    Ritter, Philippe
    Hocini, Meleze
    Dos Santos, Pierre
    Haissaguerre, Michel
    Jais, Pierre
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01): : 144 - 150
  • [6] Contact force and ablation assessment of surgical bipolar radiofrequency clamps in the treatment of atrial fibrillation
    Varzaly, Jason A.
    Chapman, Darius
    Lau, Dennis H.
    Edwards, Suzanne
    Louise, Jennie
    Edwards, James
    Mahajan, Rajiv
    Worthington, Michael
    Sanders, Prashanthan
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 28 (01) : 85 - 93
  • [7] Initial impedance decrease as an indicator of good catheter contact: Insights from radiofrequency ablation with force sensing catheters
    Reichlin, Tobias
    Knecht, Sven
    Lane, Christopher
    Kuehne, Michael
    Nof, Eyal
    Chopra, Nagesh
    Tadros, Thomas M.
    Reddy, Vivek Y.
    Schaer, Beat
    John, Roy M.
    Osswald, Stefan
    Stevenson, William G.
    Sticherling, Christian
    Michaud, Gregory F.
    HEART RHYTHM, 2014, 11 (02) : 194 - 201
  • [8] Improved Ablation Efficiency in PVI Guided by Contact Force and Local Impedance: Chronic Canine Model
    Gutbrod, Sarah R.
    Shuros, Allan
    Koya, Vijay
    Alexander-Curtis, Michelle
    Lehn, Lauren
    Miklos, Kimberly
    Mounsey, John Paul
    Meyers, Jason D.
    FRONTIERS IN PHYSIOLOGY, 2022, 12
  • [9] RELATION BETWEEN IMPEDANCE AND ENDOCARDIAL CONTACT DURING RADIOFREQUENCY CATHETER ABLATION
    STRICKBERGER, SA
    VORPERIAN, VR
    MAN, KC
    WILLIAMSON, BD
    KALBFLEISCH, SJ
    HASSE, C
    MORADY, F
    LANGBERG, JJ
    AMERICAN HEART JOURNAL, 1994, 128 (02) : 226 - 229
  • [10] Contact Force Increases During Radiofrequency Ablation A Novel Catheter Assessment of Myocardial Response to Thermal Injury
    Watanabe, Keita
    Nies, Moritz
    Rodrigues, Steffy
    Reddy, Vivek Y.
    Koruth, Jacob S.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2025, 11 (02) : 337 - 349