Evaluation of a neck shield for use during neurological studies with a whole-body PET scanner

被引:22
|
作者
Thompson, CJ
Kecani, S
Boelen, S
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ H3A 2B4, Canada
[2] McGill Univ, Dept Phys, Montreal, PQ, Canada
[3] InCoDe Pte, Pointe Claire, PQ, Canada
关键词
D O I
10.1109/23.958389
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is well known that the shielding against out-of-field scattered radiation is not very effective on whole-body positron emission tomography (PET) scanners operated with their slice-defining septa retracted. Additional shielding can be employed during neurological studies since the diameter of the head is much less than the field of view required for imaging the human torso. We have designed, built, and tested (on the CTI HR+PET scanner) a new lead-plate shielding system that mounts on the scanner's removable headrest. We call this device the "NeuroShield." The outer diameter of the 9-mm-thick lead plate is 550 mm, which has a "U"-shaped hole 220 min. in diameter. It is positioned just above the subject's shoulders. A molded plastic coupling piece, produced by stereo-lithography, was designed to accommodate the complex shape of the headrest under the subject's neck and provide a flat surface for mounting the lead plate. Our testing on human subjects involved comparing the prompt and random count rates and dead time during bolus-water activation studies. Scans on different subjects (matched for age and sex) with no additional shielding, with the CTI neurological insert, and with the NeuroShield were compared. The random counts were reduced by a factor of 1.56 when using the permanent CTI neurological insert and 1.44 using the NeuroShield. The NeuroShield is easily removed to allow whole-body scanning. It can remain in place as the couch extends through the scanning tunnel in the gantry. Its main application will be at PET centers doing a mixture of whole-body and neurological studies, where the CTI neurological insert cannot be installed permanently.
引用
收藏
页码:1512 / 1517
页数:6
相关论文
共 50 条
  • [1] Performance evaluation of a whole-body PET scanner using the NEMA protocol
    Brix, G
    Zaers, J
    Adam, LE
    Bellemann, ME
    Ostertag, H
    Trojan, H
    Haberkorn, U
    Doll, J
    Oberdorfer, F
    Lorenz, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (10) : 1614 - 1623
  • [2] Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
    Delso, G.
    Martinez-Moeller, A.
    Bundschuh, R. A.
    Ladebeck, R.
    Candidus, Y.
    Faul, D.
    Ziegler, S. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15): : 4361 - 4374
  • [3] PERFORMANCE-CHARACTERISTICS OF A WHOLE-BODY PET SCANNER
    DEGRADO, TR
    TURKINGTON, TG
    WILLIAMS, JJ
    STEARNS, CW
    HOFFMAN, JM
    COLEMAN, RE
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (08) : 1398 - 1406
  • [4] Performance evaluation of the whole-body PET scanner ECAT EXACT HR+
    Adam, LE
    Zaers, J
    Ostertag, H
    Trojan, H
    Bellemann, ME
    Brix, G
    Lorenz, WJ
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1270 - 1274
  • [5] Performance evaluation of the new whole-body PET/CT scanner: Discovery ST
    Valentino Bettinardi
    Massimo Danna
    Annarita Savi
    Michela Lecchi
    Isabella Castiglioni
    Maria Carla Gilardi
    Helmut Bammer
    Giovanni Lucignani
    Ferruccio Fazio
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 867 - 881
  • [6] Performance evaluation of the new whole-body PET/CT scanner: Discovery ST
    Bettinardi, V
    Danna, M
    Savi, A
    Lecchi, M
    Castiglioni, I
    Gilardi, MC
    Bammer, H
    Lucignani, G
    Fazio, F
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (06) : 867 - 881
  • [7] A prototype axial shield for use in 3D whole-body PET
    Cutler, PD
    Laforest, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 10 - 15
  • [8] On the use of positioning aids to reduce misregistration in the head and neck in whole-body PET/CT studies
    Beyer, T
    Tellmann, L
    Nickel, I
    Pietrzyk, U
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (04) : 596 - 602
  • [9] PRELIMINARY EVALUATION OF EMI WHOLE-BODY SCANNER
    KREEL, L
    JOURNAL BELGE DE RADIOLOGIE, 1976, 59 (03): : 267 - 280
  • [10] PRELIMINARY EVALUATION OF EMI WHOLE-BODY SCANNER
    KREEL, L
    JOURNAL BELGE DE RADIOLOGIE, 1976, 59 (05): : 477 - 477