摘要
The electrical transformer is one of the most used equipment in electrical power systems. The non-linear electrical loads are increasing, mainly in the electrical distribution system, and the electrical power transformer is inserted in this scenario, supplying these loads. Consequently, the increasing non-linear loads affect the electrical transformers and their factors directly, like in the dependency between temperature and harmonic increase. Therefore, to study the influence of harmonics in the transformer's temperature, one should understand how it will behave with these changes in the electrical power system. For this reason, in this article, numeric simulations and tests were performed to predict the transformer temperature behavior. The proposal is a numeric technique for coupling two equations, thermal and electromagnetic, of an electrical transformer, considering heat sources regarding joule, eddy current, and hysteresis effect. To evaluate the numeric simulation and understanding the electrical transformer behavior in real-life, tests with specific harmonic orders (3rd, 5th, and 7th) and their combinations and a test with less than 10% total harmonic distortion, according to IEEE 519 standard were performed. It is verified that the electrical transformer temperature rises with the increase in harmonic amplitude and its orders. Results show that the industry must be aware of the effects of the increasing non-linear loads when designing the next generation of transformers concerning their durability and lifetime.
引用
收藏
页数:14
相关论文
共 6 条
  • [1] HARMONIC DOMAIN ANALYSIS OF FIELD VARIABLES RELATED TO EDDY-CURRENT AND HYSTERESIS LOSSES IN SATURATED LAMINATIONS
    RAJAKOVIC, N
    SEMLYEN, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) : 1111 - 1116
  • [2] Three-Phase Transformer Modeling Using a Vector Hysteresis Model and Including the Eddy Current and the Anomalous Losses
    Ferreira da Luz, Mauricio Valencia
    Leite, Jean Vianei
    Benabou, Abdelkader
    Sadowski, Nelson
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (08) : 3201 - 3204
  • [3] Analysis of Hysteresis and Eddy-Current Losses for a Medium-Frequency Transformer in an Isolated DC-DC Converter
    Nakahara, Mizuki
    Wada, Keiji
    2014 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-HIROSHIMA 2014 - ECCE-ASIA), 2014, : 2511 - 2516
  • [4] A Comprehensive 2D FE-SIBC Model for Calculating the Eddy Current Losses in a Transformer Tank-Wall
    Diaz-Chacon, J. M.
    Hernandez, C.
    Arjona, M. A.
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2012, 27 (08): : 646 - 653
  • [5] Nonlinear analysis of eddy current and hysteresis losses of 3-D stray field loss model (Problem 21)
    Takahashi, N
    Sakura, T
    Cheng, ZG
    IEEE TRANSACTIONS ON MAGNETICS, 2001, 37 (05) : 3672 - 3675
  • [6] Analysis of Eddy-Current Losses in Solid Iron Under dc-Biased Magnetization Considering Minor Hysteresis Loops
    Shima, Kazuo
    Fukami, Tadashi
    Miyata, Kenji
    Lee, Chahn
    Furukawa, Yoko
    ELECTRICAL ENGINEERING IN JAPAN, 2014, 188 (03) : 56 - 66