Blood oxygen level-dependent liver MRI: Can It predict microvascular invasion in HCC?

被引:19
|
作者
Jhaveri, Kartik S. [1 ,2 ]
Cleary, Sean P. [3 ]
Fischer, Sandra [4 ]
Haider, Masoom A. [1 ,2 ]
Pargoankar, Vivek [1 ,2 ]
Khalidi, Karim [1 ,2 ]
Moshonov, Hadas [1 ,2 ]
Gallinger, Steven [3 ]
机构
[1] Univ Toronto, Joint Dept Med Imaging, Univ Hlth Network, Toronto, ON M5S 1A1, Canada
[2] Univ Toronto, Mt Sinai Hosp, Toronto, ON M5S 1A1, Canada
[3] Univ Toronto, Dept Surg, Div Hepatobiliary Surg, Univ Hlth Network, Toronto, ON M5S 1A1, Canada
[4] Univ Toronto, Dept Pathol, Univ Hlth Network, Toronto, ON M5S 1A1, Canada
关键词
hepatocellular carcinoma (HCC); magnetic resonance imaging (MRI); blood oxygen level dependent MRI (BOLD MRI); microvascular invasion (MVI); cirrhosis; liver transplantation; HEPATOCELLULAR-CARCINOMA; HEPATIC RESECTION; RISK-FACTORS; PREOPERATIVE ASSESSMENT; ARTERIAL PORTOGRAPHY; EARLY RECURRENCE; PROSTATE-CANCER; PORTAL-VEIN; HYPOXIA; CT;
D O I
10.1002/jmri.23858
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess Blood Oxygen Level-Dependent (BOLD) Magnetic Resonance Imaging (MRI) for noninvasive preoperative prediction of Microvascular Invasion (MVI) in Hepatocellular Carcinoma (HCC). Materials and Methods: In this prospective, institutional review board approved study, 26 patients (21 men and 5 women age range, 3477 years with mean age of 61 years) with HCC were evaluated preoperatively with liver MRI including baseline and post oxygen (O2) breathing BOLD MRI. Post processing of MRI data was performed to obtain R2* values (1/s) and correlated with histopathological assessment of MVI. Statistical analysis was performed to assess correlation of baseline R2*, post O2 R2* and R2* ratios to presence of MVI in HCC by binary logistic regression analysis. Results: MVI was present in 15/26 (58%) of HCC on histopathology. The mean R2* values +/- SD at baseline and post O2 with and without MVI were 35 +/- 12, 36 +/- 12, 38 +/- 10, 42 +/- 17. The R2* values between the groups with and without MVI were not significantly different statistically. Conclusion: BOLD MRI is unable to accurately predict MVI in HCC. The noninvasive preoperative MRI detection of MVI in HCC remains elusive. J. Magn. Reson. Imaging 2013;37:692699. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:692 / 699
页数:8
相关论文
共 50 条
  • [1] Oxygen Imaging by MRI Can Blood Oxygen Level-Dependent Imaging Depict the Ischemic Penumbra?
    Jensen-Kondering, Ulf
    Baron, Jean-Claude
    STROKE, 2012, 43 (08) : 2264 - U499
  • [2] Blood Oxygen Level-Dependent (BOLD) MRI in Renovascular Hypertension
    Gloviczki, Monika L.
    Lerman, Lilach O.
    Textor, Stephen C.
    CURRENT HYPERTENSION REPORTS, 2011, 13 (05) : 370 - 377
  • [3] MRI FEATURES OF HCC DO NOT PREDICT MICROVASCULAR INVASION IN LIVER TRANSPLANT FOR HEPATOCELLULAR CARCINOMA
    Robinson, Emma
    Chandarana, Hersh
    Droxhinin, Leonid
    Hajdu, Cristina
    Xu, Ruliang
    Teperman, Lewis
    Taouli, Bachir
    LIVER TRANSPLANTATION, 2009, 15 (07) : S111 - S111
  • [4] Blood Oxygen Level-dependent MRI for Evaluation of Early Response of Liver Tumors to Chemoembolization: an Animal Study
    Choi, Jin Woo
    Kim, Hyeonjin
    Kim, Hyo-Cheol
    Lee, Yunjung
    Kwon, Jeongmin
    Yoo, Roh-Eul
    Cho, Hye Rim
    Choi, Seung Hong
    Chung, Jim Wook
    ANTICANCER RESEARCH, 2013, 33 (05) : 1887 - 1892
  • [5] Blood Oxygen Level-Dependent (BOLD) MRI of Diabetic Nephropathy: Preliminary Experience
    Wang, Zhen J.
    Kumar, Rahi
    Banerjee, Suchandrima
    Hsu, Chi-yuan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (03) : 655 - 660
  • [6] Measurement of renal tissue oxygenation with blood oxygen level-dependent MRI and oxygen transit modeling
    Zhang, Jeff L.
    Morrell, Glen
    Rusinek, Henry
    Warner, Lizette
    Vivier, Pierre-Hugues
    Cheung, Alfred K.
    Lerman, Lilach O.
    Lee, Vivian S.
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2014, 306 (06) : F579 - F587
  • [7] Does microvascular invasion predict recurrence after liver transplantation for HCC?
    Shah, SA
    Tan, JR
    McGilvray, ID
    Cattral, MS
    Kim, RD
    Mathe, Z
    Levy, GA
    Greig, PD
    Grant, DR
    AMERICAN JOURNAL OF TRANSPLANTATION, 2005, 5 : 234 - 234
  • [8] Blunted Frontostriatal Blood Oxygen Level-Dependent Signals Predict Stimulant and Marijuana Use
    Blair, Melanie A.
    Stewart, Jennifer L.
    May, April C.
    Reske, Martina
    Tapert, Susan F.
    Paulus, Martin P.
    BIOLOGICAL PSYCHIATRY-COGNITIVE NEUROSCIENCE AND NEUROIMAGING, 2018, 3 (11) : 947 - 958
  • [9] Blood oxygen level-dependent (BOLD) MRI analysis in atherosclerotic renal artery stenosis
    Gloviczki, Monika L.
    Saad, Ahmed
    Textor, Stephen C.
    CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2013, 22 (05): : 519 - 524
  • [10] Cerebrovascular Reactivity in Idiopathic Intracranial Hypertension Measured by Blood Oxygen Level-Dependent MRI
    Hui, Benjamin
    Sharpe, James
    Poublanc, Julien
    Chmielewski, Aneta
    Fierstra, Jorn
    Mandell, Daniel
    Mikulis, David
    NEUROLOGY, 2012, 78