A method to calibrate beam position monitor at HLS 200 MeV LINAC

被引:0
|
作者
Li, JH [1 ]
Sun, BG [1 ]
He, DH [1 ]
Lu, P [1 ]
Wang, Y [1 ]
Wang, JH [1 ]
Jin, K [1 ]
Cao, Y [1 ]
Zheng, P [1 ]
机构
[1] Univ Sci & Technol China, NSRL, Hefei 230029, Anhui, Peoples R China
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to improve injection efficiency of HLS 200Mev LINAC, we redesign a new strip line beam position monitor system, which is consisted of a strip line structure and a signal processing system. We decide on an online calibration method based on beam to find out the geometry centre displacement and relative gain offset. Before the BPM testing bench has been prepared, we make a simulation based on the model accounted for all factors influencing signal amplitudes and get the calibrating results. At last, we analyze the nonlinearity effect on the calibration results.
引用
收藏
页码:2379 / 2381
页数:3
相关论文
共 50 条
  • [1] Strip line beam position monitor for HLS LINAC
    LI Ji-Hao*
    Nuclear Science and Techniques, 2005, (05) : 257 - 259
  • [2] Design and simulation of beam position monitor for 20OMeV Linac in HLS
    Li, JH
    Sun, BG
    He, DH
    Lu, P
    Wang, Y
    Wang, JH
    Jin, K
    Cao, Y
    Zheng, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1785 - 1787
  • [3] Beam energy spectrum monitor for the Hefei 200MeV Linac
    Sun, Baogen
    Fang, Zhigao
    Wang, Guicheng
    Li, Hui
    Wang, Junhua
    Xie, Rongsheng
    Wang, Jihong
    Zhang, Danhong
    He Jishu/Nuclear Techniques, 21 (01): : 48 - 50
  • [4] LINAC BEAM POSITION MONITOR
    BERGERE, R
    DAUJAT, P
    VEYSSIERE, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (12): : 1441 - &
  • [5] Beam position monitor system design in l00 MeV linac
    Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
    He Jishu, 2007, 1 (1-4): : 1 - 4
  • [6] Measurement of the beam position monitor electronics sensitivity for PEFP 100-MeV linac and beam line
    Ryu, Jin-Yeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1307 - 1310
  • [7] Measurement of the beam position monitor electronics sensitivity for PEFP 100-MeV linac and beam line
    Jin-Yeong Ryu
    Journal of the Korean Physical Society, 2013, 63 : 1307 - 1310
  • [8] Application and design of photon beam position monitor in HLS
    Sun, BG
    He, DH
    Lu, P
    Wang, Y
    Xu, HL
    Lin, SF
    Wang, JH
    Cao, Y
    Li, JH
    Zheng, P
    Zhang, CH
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1782 - 1784
  • [9] Development of a split photon beam position monitor for HLS
    Sun, BG
    He, DH
    Lu, P
    Wang, JH
    Guo, CL
    Wang, Y
    Cao, Y
    Li, JH
    Zheng, P
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (02): : 210 - 214
  • [10] Beam position monitor systems for the SNS linac
    Power, J
    Day, L
    Plum, M
    Stettler, M
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2429 - 2431