Frequency analysis of DC tolerant current transformers

被引:1
|
作者
Mlejnek, P. [1 ]
Kaspar, P. [1 ]
机构
[1] Czech Tech Univ, Kladno 27201, Czech Republic
关键词
D O I
10.1088/1742-6596/459/1/012053
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This article deals with wide frequency range behaviour of DC tolerant current transformers that are usually used in modern static energy meters. In this application current transformers must comply with European and International Standards in their accuracy and DC tolerance. Therefore, the linear DC tolerant current transformers and double core current transformers are used in this field. More details about the problems of these particular types of transformers can be found in our previous works. Although these transformers are designed mainly for power distribution network frequency (50/60 Hz), it can be interesting to understand their behaviour in wider frequency range. Based on this knowledge the new generations of energy meters with measuring quality of electric energy will be produced. This solution brings better measurement of consumption of nonlinear loads or measurement of non-sinusoidal voltage and current sources such as solar cells or fuel cells. The determination of actual power consumption in such energy meters is done using particular harmonics component of current and voltage. We measured the phase and ratio errors that are the most important parameters of current transformers, to characterize several samples of current transformers of both types.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Measurement of ratio error and phase displacement of DC tolerant current transformers
    Mlejnek, Pavel
    Kaspar, Petr
    Draxler, Karel
    [J]. SENSOR LETTERS, 2007, 5 (01) : 289 - 292
  • [2] Thermal Analysis of Inverters and High Frequency Transformers in the DC-DC Converters
    Rezaei, Hossein
    Babaei, Abolfazl
    [J]. 2017 IEEE 4TH INTERNATIONAL CONFERENCE ON KNOWLEDGE-BASED ENGINEERING AND INNOVATION (KBEI), 2017, : 125 - 130
  • [3] Effect Analysis of DC Bias on the Transfer Characteristics of Current Transformers
    Pu, Yuan
    Fan, Haoran
    Lin, Sheng
    [J]. 2023 5TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES, 2023, : 201 - 206
  • [4] Rotor DC Current Measurement by Using Current Transformers
    Gajic, Z.
    Trisic, D.
    Roxenborg, S.
    [J]. 2015 68TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2015, : 379 - 388
  • [5] The Characteristics of Electromagnetic Current Transformers with DC Bias
    Li, Changyun
    Li, Qingmin
    Yao, Jinxia
    Liu, Min
    [J]. 2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 73 - +
  • [6] Harmonic analysis of transformers under converter load with DC and low frequency bias
    Wang, ZY
    Liu, YL
    [J]. PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59, I AND II, 1997, 59 : 449 - 454
  • [7] Harmonic analysis of transformers under converter load with DC and low frequency bias
    Wang, ZY
    Liu, YL
    [J]. PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 59 - PTS I AND II, 1997, 59 : 449 - 454
  • [8] Frequency Response of MV Current Transformers
    Chen, J. C.
    Phung, B. T.
    Zhang, D. M.
    Blackburn, T.
    [J]. 2013 IEEE TENCON SPRING CONFERENCE, 2013, : 332 - 336
  • [9] WIDE FREQUENCY RANGE CURRENT TRANSFORMERS
    ANDERSON, JM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (07): : 915 - &
  • [10] Frequency response of Measurement Current Transformers
    Cataliotti, A.
    Di Cara, D.
    Di Franco, P. A.
    Emanuel, A. E.
    Nuccio, S.
    [J]. 2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 1254 - +