One important cause of disturbances in distribution systems is lightning that determines permanent or transient faults in overhead lines by direct or more frequently indirect strokes. The trouble caused to customers, because of the susceptibility of some loads, may be very severe even in the case of transient faults, i.e. those which disappear after the opening and high-speed reclosure of protective breakers, The paper provides an assessment of the reduction in the number of faults caused by the lightning activity to an MV distribution system by the addition of a shield wire. The effect of an increase in the insulation level is also analysed.
引用
收藏
页码:361 / 372
页数:12
相关论文
共 21 条
  • [1] Evaluation of the Mitigation Effect of the Shield Wires on Lightning Induced Overvoltages in MV Distribution Systems Using Statistical Analysis
    Brignone, Massimo
    Mestriner, Daniele
    Procopio, Renato
    Piantini, Alexandre
    Rachidi, Farhad
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2018, 60 (05) : 1400 - 1408
  • [2] Lightning-Induced Voltages on Distribution Lines with Shield Wires
    Piantini, Alexandre
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [3] LIGHTNING - INDUCED OVERVOLTAGES ON OVERHEAD DISTRIBUTION LINES
    ERIKSSON, AJ
    STRINGFELLOW, MF
    MEAL, DV
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (04): : 960 - 968
  • [4] LIGHTNING - INDUCED OVERVOLTAGES ON OVERHEAD DISTRIBUTION LINES.
    Eriksson, Andrew J.
    Stringfellow, Michael F.
    Meal, Dave V.
    SAE Preprints, 1981,
  • [5] Analysis of the effectiveness of shield wires in mitigating lightning-induced voltages on power distribution lines
    Piantini, Alexandre
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 159 : 9 - 16
  • [6] Mitigation of Lightning-Induced Overvoltages Using Shield Wires: Application of the Response Surface Method
    Brignone, Massimo
    Mestriner, Daniele
    Procopio, Renato
    Rachidi, Farhad
    Piantini, Alexandre
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [7] Improvement of the lightning shielding performance of overhead transmission lines by passive shield wires
    Metwally, IA
    Heidler, FH
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (02) : 378 - 392
  • [8] NEW CONCEPTS ON MV DISTRIBUTION FROM INSULATED SHIELD WIRES OF HV LINES
    ILICETO, F
    CINIERI, E
    CASELYHAYFORD, L
    DOKYI, G
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (04) : 2130 - 2144
  • [9] On the Role of Shield Wires in Mitigating Lightning-Induced Overvoltages in Overhead Lines-Part II: Simulation Results for Practical Configurations
    Andreotti, Amedeo
    Araneo, Rodolfo
    Faria, J. Brandao
    He, Jinliang
    Petrache, Emanuel
    Pierno, Antonio
    Stracqualursi, Erika
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (01) : 345 - 352
  • [10] On the Role of Shield Wires in Mitigating Lightning-Induced Overvoltages in Overhead Lines-Part I: A Critical Review and a New Analysis
    Andreotti, Amedeo
    Araneo, Rodolfo
    Faria, J. Brandao
    He, Jinliang
    Petrache, Emanuel
    Pierno, Antonio
    Stracqualursi, Erika
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (01) : 335 - 344