Optimization of the position resolution in semiconductor detectors

被引:2
|
作者
Jeong, Manhee [1 ]
Lawlor, David A. [2 ]
Hammig, Mark D. [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[2] Galt LLC, Ann Arbor, MI 48130 USA
关键词
D O I
10.1109/NSSMIC.2007.4437275
中图分类号
O59 [应用物理学];
学科分类号
摘要
In our effort to image the cloud of mobile charge-carriers induced by a radiation interaction in a solid-state material, we have performed a fundamental investigation of the electrode design and pulse shape analysis routines required to optimize the detector's position resolution, when limited by both temporal and carrier uncertainty. The interactions of ions and gamma-rays with silicon are modeled using Monte Carlo techniques so that the currents induced on the measurement electrodes can be predicted. Those predictions are then compared to the measured results derived from a high-resistivity silicon detector, on which metal-semiconductor junctions are used to form the rectifying and ohmic contacts.
引用
收藏
页码:1456 / +
页数:2
相关论文
共 50 条
  • [1] Sub-pixel position resolution in pixelated semiconductor detectors
    Anderson, Stephen E.
    Donmez, Burcin
    He, Zhong
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1569 - 1576
  • [2] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS
    RADEKA, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (01): : 209 - 218
  • [3] LINEARITY AND RESOLUTION OF SEMICONDUCTOR RADIATION DETECTORS
    ZULLIGER, HR
    MIDDLEMAN, LM
    AITKEN, DW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1969, NS16 (01) : 47 - +
  • [4] RESOLUTION OF SEMICONDUCTOR DETECTORS FOR FISSION FRAGMENTS
    HAINES, EL
    WHITEHEA.AB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (09): : 1385 - &
  • [5] TIME RESOLUTION IN SEMICONDUCTOR-DETECTORS
    ELWAHAB, MA
    SAKKA, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 117 - 120
  • [6] POSITION-SENSITIVE SEMICONDUCTOR-DETECTORS
    LAEGSGAARD, E
    NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3): : 93 - 111
  • [7] New structure for position sensitive semiconductor detectors
    Kemmer, J.
    Lutz, G.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 588 - 598
  • [8] ANALOG DIVISION CIRCUIT FOR SEMICONDUCTOR POSITION DETECTORS
    VOLODYAGIN, YS
    GUNER, MA
    KLEINMENOV, VF
    KOBLIK, YN
    KUDRYAVTSEV, VN
    MAZITOV, BS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1976, 19 (03) : 721 - 723
  • [9] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS.
    Radeka, V.
    Nuclear instruments and methods in physics research, 1983, 226 (01): : 209 - 218
  • [10] STRIPED SEMICONDUCTOR DETECTORS FOR DIGITAL POSITION ENCODING
    HAASE, EL
    FAWZI, MA
    VELTEN, E
    SAYLOR, DP
    NUCLEAR INSTRUMENTS & METHODS, 1971, 97 (03): : 465 - +