Evaluation of central corneal thickness after cataract surgery, penetrating keratoplasty and long-term soft contact lens wear

被引:5
|
作者
Sel, Saadettin [1 ,2 ]
Trau, Stefanie [3 ]
Knak, Matthias [3 ]
Kalinski, Thomas [4 ]
Kaiser, Delia [4 ]
Kruse, Friedrich E. [2 ]
Huchzermeyer, Cord [2 ]
Duncker, Gernot I. W. [5 ]
Paulsen, Friedrich [6 ]
Auffarth, Gerd U. [1 ]
Nass, Norbert [4 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, Heidelberg, Germany
[2] Univ Erlangen Nurnberg, Dept Ophthalmol, D-91054 Erlangen, Germany
[3] Univ Halle Wittenberg, Dept Ophthalmol, D-06108 Halle, Germany
[4] Otto Von Guericke Univ, Dept Pathol, Magdeburg, Germany
[5] Eye Laser Inst, Halle, Germany
[6] Univ Erlangen Nurnberg, Inst Anat, Dept 2, D-91054 Erlangen, Germany
来源
CONTACT LENS & ANTERIOR EYE | 2013年 / 36卷 / 05期
关键词
Central corneal thickness; Pachymetry; Intraocular lens; Phacoemulsification; Penetrating keratoplasty; Soft contact lens; ROTATING SCHEIMPFLUG CAMERA; ULTRASONIC PACHYMETRY; TOPOGRAPHY;
D O I
10.1016/j.clae.2013.03.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare central corneal thickness (CCT) between corneas of normal healthy eyes (cNHE), corneas of eyes that had undergone cataract surgery by clear corneal phacoemulsification with implantation of an intracapsular intraocular lens (cIOL), corneal grafts after penetrating keratoplasty (gPK) and corneas of long-term soft contact lens wearers (cCL). Methods: The study design was a consecutive cross-sectional trial. CCT was measured using rotating Scheimpflug camera (Pentacam, software version 1.16r04) in 80 cNHE, 79 cIOL, 46 gPK and 78 cCL. Analysis of variance (one-way ANOVA) was performed to compare differences of mean values between these four groups. Pearson's or Spearman's correlation coefficient (r) was determined between CCT value and age, follow up time after penetrating keratoplasty (timePK) or contact lens wearing time (timeCL). Results: Means of CCf measurements were comparable between cNHE (mean CCT +/- standard deviation, 554 +/- 36 mu m), cIOL (551 +/- 40 mu m) and gPK (534 +/- 52 mu m) as determined by one-way ANOVA. Mean CCT values in cCL (537 +/- 37 mu m) were statistically significantly lower in comparison to cNHE (p = 0.026, 95% CI = 1.43-31.44). There was no linear correlation between age and CCT values of cNHE and cIOL (p = 0.841, r = -0.031 and p = 0.931, r = 0.011, respectively). No linear relationship was determined between CCf values of cCL and timeCL(p = 0.315, r = -0.125). CCT values of gPK did not correlate with timePK (p = 0.738, r = 0.054). Conclusions: The data reported here indicate that in the same statistical model among CCT values of cNHE, cIOL and gPK only long-term soft contact lenses (CL) wearer have significantly lower CCT measurements. (C) 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:238 / 242
页数:5
相关论文
共 50 条
  • [1] Effects of long-term soft contact lens wear on the corneal thickness and corneal epithelial thickness of myopic subjects
    Lei, Yulin
    Zheng, Xiuyun
    Hou, Jie
    Xu, Baozeng
    Mu, Guoying
    [J]. MOLECULAR MEDICINE REPORTS, 2015, 11 (03) : 2020 - 2026
  • [2] Effects of long-term soft contact lens wear on corneal epithelial thickness after small incision lenticule extraction
    Wang, Yun
    Zhang, Xiaofeng
    Yang, Xiaolong
    Xu, Yue
    Luo, Baogen
    Qian, Yifeng
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2022, 23 (01)
  • [3] The effects of long-term contact lens wear on corneal thickness, curvature, and surface regularity
    Liu, ZG
    Pflugfelder, SC
    [J]. OPHTHALMOLOGY, 2000, 107 (01) : 105 - 111
  • [4] Time to resolution of corneal edema after long-term contact lens wear
    Nourouzi, Hamid
    Rajavi, Jaleh
    Okhovatpour, Mohamad Ali
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (04) : 671 - 673
  • [5] THE EFFECT OF HARD CONTACT-LENS WEAR ON THE KERATOCONIC CORNEAL ENDOTHELIUM AFTER PENETRATING KERATOPLASTY
    MATSUDA, M
    MACRAE, SM
    INABA, M
    MANABE, R
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (03) : 246 - 251
  • [6] EVALUATION OF CORNEAL THICKNESS INDUCED BY HARD AND SOFT CONTACT-LENS WEAR
    ELHAGE, SG
    HUGHES, CC
    SCHAUER, KR
    JARRELL, RL
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1972, 49 (11): : 973 - +
  • [7] Effects of long-term contact lens wear on the corneal endothelium
    Setala, K
    Vasara, K
    Vesti, E
    Ruusuvaara, P
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (03): : 299 - 303
  • [8] Long-term changes in corneal surface configuration after penetrating keratoplasty
    Hayashi, K
    Hayashi, H
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (02) : 241 - 247
  • [9] Influence of extended soft contact lens wear on the comparative measurement of central corneal thickness
    Lattimore, MR
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 1996, 74 (03): : 239 - 242
  • [10] Does Long-term Soft Contact Lens Wear Affect Corneal and Anterior Chamber Parameters?
    Cavdarli, Cemal
    Topcu-Yilmaz, Pinar
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (04): : 166 - 170