Zinc and copper in roof runoff

被引:2
|
作者
Horvath, A. [1 ]
Buzas, K. [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Sanit & Environm Engn, H-1111 Budapest, Hungary
关键词
contact time; copper; deposition; dissolution; roof runoff; zinc; ATMOSPHERIC DEPOSITION; TRACE-METALS; WATER-POLLUTION; CORROSION; URBAN; RAINWATER; QUALITY; RATES; NO2;
D O I
10.2166/wst.2013.044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The zinc and copper content of roof runoff could originate from different sources such as dry and wet deposition and the corrosion of the material. The zinc runoff rate from a galvanized surface depends on the corrosion products formed during the dry days, the rain intensity and roof slope, which determinates the contact time. In the present study the contact time dependence of zinc rate and the re-dissolution of the zinc were investigated with steeping tests and a pilot study. The average zinc runoff measured in the first 2.8 l of runoff was 3.8 mg m(-2) (1.1-8.4 mg m(-2)), while in the following samples 1.2 mg m(-2) were detected. These results are in accordance with the 5-10 min, and 40-60 s contact time laboratory steeping test, respectively, which are realistic. The estimated specific yearly zinc runoff rate was 0.7 g m(-2) y(-1), while the dry and wet deposition rate of copper was 0.009 mg m(-2) d(-1) and 0.053 mg m(-2) storm(-1) respectively. The re-dissolution of the zinc from the evaporated then re-filled samples of leaching tests with high initial zinc content was just 60% after 60 min.
引用
收藏
页码:1734 / 1739
页数:6
相关论文
共 50 条
  • [1] Effects of roof and rainwater characteristics on copper concentrations in roof runoff
    Gretchen K. Bielmyer
    W. Ray Arnold
    Joseph R. Tomasso
    Jeff J. Isely
    Stephen J. Klaine
    Environmental Monitoring and Assessment, 2012, 184 : 2797 - 2804
  • [2] Effects of roof and rainwater characteristics on copper concentrations in roof runoff
    Bielmyer, Gretchen K.
    Arnold, W. Ray
    Tomasso, Joseph R.
    Isely, Jeff J.
    Klaine, Stephen J.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2012, 184 (05) : 2797 - 2804
  • [3] Copper and zinc removal from roof runoff: from research to full-scale adsorber systems
    Steiner, M
    Boller, M
    WATER SCIENCE AND TECHNOLOGY, 2006, 53 (03) : 199 - 207
  • [4] Estimations of Copper Roof Runoff Rates in the United States
    Arnold, Ray
    INTEGRATED ENVIRONMENTAL ASSESSMENT AND MANAGEMENT, 2005, 1 (04) : E15 - E32
  • [5] Environmental impact of stormwater runoff from a copper roof
    Michels, HT
    Boulanger, B
    Nikolaidis, NP
    MATERIALS PERFORMANCE, 2003, 42 (02) : 70 - 74
  • [6] Performance of a zeolite filter treating copper roof runoff
    Milovanovic, Ivan
    Hedstrom, Annelie
    Herrmann, Inga
    Viklander, Maria
    URBAN WATER JOURNAL, 2022, 19 (05) : 499 - 508
  • [7] Infiltration of a copper roof runoff through artificial barriers
    Athanasiadis, K.
    Helmreich, B.
    Wilderer, P. A.
    WATER SCIENCE AND TECHNOLOGY, 2006, 54 (6-7) : 281 - 289
  • [8] A field study on the first flush effect of copper roof runoff
    Athanasiadis, K.
    Horn, H.
    Helmreich, B.
    CORROSION SCIENCE, 2010, 52 (01) : 21 - 29
  • [9] Development of an on-site Fe0 system for treatment of copper- and zinc-contaminated roof runoff
    Rangsivek R.
    Jekel M.R.
    International Journal of Environment and Waste Management, 2011, 8 (3-4) : 353 - 365
  • [10] Runoff of copper and zinc caused by atmospheric corrosion
    Leuenberger-Minger, A.U.
    Faller, M.
    Richner, P.
    Materials and Corrosion, 2002, 53 (03) : 157 - 164