Minimum effective volume of 0.5 bupivacaine with epinephrine in ultrasound-guided interscalene brachial plexus block

被引:29
|
作者
Falcao, L. F. R. [1 ]
Perez, M. V. [1 ]
de Castro, I. [1 ]
Yamashita, A. M. [1 ]
Tardelli, M. A. [1 ]
Amaral, J. L. G. [1 ]
机构
[1] Univ Fed Sao Paulo, Discipline Anaesthesiol Pain & Crit Care Med, Fed Univ Sao Paulo,Hosp Sao Paulo, Paulista Sch Med,Escola Paulista Med UNIFESP EPM, BR-04024002 Sao Paulo, Brazil
关键词
anaesthetic; local; brachial plexus; bupivacaine; ultrasonography; EFFECTIVE ANESTHETIC VOLUME; HEMIDIAPHRAGMATIC PARESIS; NERVE-STIMULATION; GUIDANCE; ROPIVACAINE;
D O I
10.1093/bja/aes419
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The use of ultrasound (US) in regional anaesthesia enables a reduction in the local anaesthetic volume. The present study aimed to determine the minimum effective volume (MEV90) of 0.5 bupivacaine with epinephrine for interscalene brachial plexus block (ISBPB). The volume of the anaesthetic was determined using a step-up/step-down method and was based on the outcome of the preceding block. A positive or negative block resulted in a 1 ml reduction or increase in volume, respectively. The success of theblock was defined as the presence of motor block in three muscle groups and the absence of thermal and pain sensations in three dermatomes within 30 min of the injection. Diaphragmatic paralysis and analgesia were assessed at 30 min, 4, and 6 h. The MEV90 for US-guided brachial plexus block under the conditions of the present study was 0.95 ml [R-2: 0.97, 95 confidence interval (CI): 0.61.22 ml]. The estimated maximum volume that did not cause diaphragmatic block was 4.29 ml (R-2: 0.84, 95 CI: 3.564.98 ml). Effective postoperative analgesia was achieved with 2.34 ml (R-2: 0.87, 95 CI: 0.4811.47 ml). The MEV90 of 0.5 bupivacaine with epinephrine (1:200 000) for US-guided ISBPB was 0.95 ml. Adequate postoperative analgesia and a reduced incidence of diaphragmatic block can be obtained using from 2.34 to 4.29 ml. ClinicalTrials.gov. Registry NCT01244932.
引用
收藏
页码:450 / 455
页数:6
相关论文
共 50 条
  • [1] Estimation of the minimum effective volume of 0.5% bupivacaine for ultrasound-guided axillary brachial plexus block
    Brenner, David G.
    Marjanek, Zsuzsanna
    Iohom, Gabriella
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2016, 33 (06) : 463 - 464
  • [2] Minimum effective volume of bupivacaine 0.5% for ultrasound-guided retroclavicular approach to infraclavicular brachial plexus block
    Kayakli, Ali Sait
    Arslan, Nilgun Kavrut Ozturk E. Ulku
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2019, 69 (03): : 253 - 258
  • [3] The Minimum Effective Anesthetic Volume of 0.75% Ropivacaine in Ultrasound-Guided Interscalene Brachial Plexus Block
    Gautier, Philippe
    Vandepitte, Catherine
    Ramquet, Caroline
    DeCoopman, Mieke
    Xu, Daquan
    Hadzic, Admir
    ANESTHESIA AND ANALGESIA, 2011, 113 (04): : 951 - 955
  • [4] The estimation of minimum effective volume of 0.5% ropivacaine in ultrasound-guided interscalene brachial plexus nerve block: A clinical trial
    Mittal, Kailash
    Janweja, Sarita
    Prateek
    Sangwan, Pushpender
    Agarwal, Deepa
    Tak, Himani
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (01) : 41 - 46
  • [5] Effect of bupivacaine concentration on the efficacy of ultrasound-guided interscalene brachial plexus block
    Tariq, Alzahrani
    Abdulaziz, Al-Ahaideb
    SAUDI JOURNAL OF ANAESTHESIA, 2011, 5 (02) : 190 - 194
  • [6] The 90% minimum effective volume of 0.5 ropivacaine for ultrasound-guided supra-clavicular brachial plexus block
    Xuan, Qinghang
    Pan, Ruoying
    Wang, Ai
    Li, Ruoyu
    Yang, Xuemei
    Yin, Guangfen
    ANAESTHESIOLOGIE, 2023, 72 : S39 - S43
  • [7] Minimum effective volume of 0.5% ropivacaine for ultrasound-guided costoclavicular brachial plexus block A dose finding study
    Wong, Ming H.
    Karmakar, Manoj K.
    Mok, Louis Y. H.
    Songthamwat, Banchobporn
    Samy, Winnie
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (09) : 780 - 786
  • [8] Minimum Effective Volume of 0.75% Ropivacaine for Ultrasound-Guided Axillary Brachial Plexus Block
    Vadagandla, Koti
    Jahagirdar, Vinay
    Rama, Kaanthi
    Qavi, Danish
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (12)
  • [9] Minimum Effective Volume of Local Anesthetic for Ultrasound-Guided Supraclavicular Brachial Plexus Block
    Duggan, Edel
    El Beheiry, Hossam
    Perlas, Anahi
    Lupu, Mario
    Nuica, Alina
    Chan, Vincent W. S.
    Brull, Richard
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (03) : 215 - 218
  • [10] Minimum effective concentration of bupivacaine for axillary brachial plexus block guided by ultrasound
    Takeda, Alexandre
    Cunha Ferraro, Leonardo Henrique
    Rezende, Andre Hosoi
    Sadatsune, Eduardo Jun
    dos Reis Falcao, Luiz Fernando
    Tardelli, Maria Angela
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2015, 65 (03): : 163 - 169