Quantitative metabolic profiling of 21 endogenous corticosteroids in urine by liquid chromatography-triple quadrupole-mass spectrometry

被引:76
|
作者
Cho, Hye-Jin [1 ,2 ]
Kim, Jong Dae [1 ]
Lee, Won-Yong [2 ]
Chung, Bong Chul [1 ]
Choi, Man Ho [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Div Life Sci, Seoul 136791, South Korea
[2] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
关键词
Corticosteroids; Liquid chromatography; Tandem mass spectrometry; Prostate diseases; ALTERED CORTISOL METABOLISM; QUANTIFICATION; STEROIDS; MINERALOCORTICOIDS; INFLAMMATION; EXTRACTION; PATTERNS; PLASMA; SALT; RAT;
D O I
10.1016/j.aca.2008.10.059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Since corticosteroid metabolism may be affected by disease states, the accurate and precise measurement of endogenous corticosteroids in urine is necessary to understand their biochemical roles. An efficient quantitative profiling of 21 endogenous corticosteroids in urine has been validated by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After enzymatic hydrolysis with beta-glucuronidase, samples were purified using a solid-phase extraction cartridge and then separated through a sub-2 mu m particle C18 column (2.1 mm x 50 mm, 1.9 mu m) and quantified within 12.1 min using a triple quadrupole MS with electrospray ionization in positive ion mode. All corticosteroids resulted in the base-line separation, which is even achieved for stereo-isomers, such as alpha-/beta-cortol, alpha-/beta-cortolone, and allo-tetrahydrocortisol/tetrahydrocortisol. Overall recoveries ranged from 85% to 106% with limit of quantification ranged from 0.5 to 2.0 ng mL(-1) for the corticosteroids examined. The precision (% CV) and accuracy (% bias) of the assay were 1.7-7.8% and 95.1-105.4%, respectively, in 0.5-200 ng mL(-1) calibration ranges (r(2) > 0.9903), for quality-control samples containing 21 endogenous corticosteroids at three different urinary concentrations. Clinical application included quantitative analysis from patients with both prostate cancer and benign prostatic hyperplasia with altered cortisol concentrations. The described LC-MS/MS method eliminates interference from other urine components, has excellent chromatographic resolution achieved by a small particle LC column with a sufficient sensitivity to allow the profiling of both gluco- and mineralo-corticosteroids at a time. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 50 条
  • [1] Quantitative Analysis Algorithm of Liquid Chromatography-Triple Quadrupole Mass Spectrometry
    Wang Y.
    Liu H.
    Sun C.
    Han W.
    Jia M.
    Jiang X.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2020, 53 (06): : 617 - 625
  • [2] Quantitative determination of 26 steroids in eggs from various species using liquid chromatography-triple quadrupole-mass spectrometry
    Mi, Xiaoxia
    Li, Sicong
    Li, Yanhua
    Wang, Kaigiang
    Zhu, Dan
    Chen, Gang
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1356 : 54 - 63
  • [3] IDENTIFICATION OF BOTULINUM TOXINS TYPE A SUBTYPES BY MAGNETIC IMMUNOCAPTURE ENRICHMENT AND LIQUID CHROMATOGRAPHY-TRIPLE QUADRUPOLE-MASS SPECTROMETRY
    Morineaux, V.
    Hilaire, D.
    Enche, J.
    Mazuet, C.
    Popoff, M. R.
    TOXICON, 2016, 116 : 83 - 83
  • [4] Determination of organophosphate diesters in urine samples by a high-sensitivity method based on ultra high pressure liquid chromatography-triple quadrupole-mass spectrometry
    Su, Guanyong
    Letcher, Robert J.
    Yu, Hongxia
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1426 : 154 - 160
  • [5] Rapid Simultaneous Determination of 11 Synthetic Cannabinoids in Urine by Liquid Chromatography-Triple Quadrupole Mass Spectrometry
    Wu, Jianbing
    Zhang, Fan
    Ke, Xing
    Jia, Wei
    Wan, Xuzhi
    Zhang, Lange
    Fan, Yilei
    Zhou, Jing
    SEPARATIONS, 2023, 10 (03)
  • [6] Analysis of butadiene urinary metabolites by liquid chromatography-triple quadrupole mass spectrometry
    McDonald, JD
    Bechtold, WE
    Krone, JR
    Blackwell, WB
    Kracko, DA
    Henderson, RF
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2004, 28 (03) : 168 - 173
  • [7] Quantitative determination of trichothecenes in breadsticks by gas chromatography-triple quadrupole tandem mass spectrometry
    Rodriguez-Carrasco, Yelko
    Font, Guillermina
    Carlos Molto, Juan
    Berrada, Houda
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2014, 31 (08): : 1422 - 1430
  • [8] Determination of aflatoxins in cereals and oils by liquid chromatography-triple quadrupole tandem mass spectrometry
    Wang Xiupin
    Li Peiwu
    Yang Yang
    Zhang Wen
    Zhang Qi
    Fan Sufang
    Yu Li
    Wang Lin
    Chen Xiaomei
    Li Ying
    Jiang Jun
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (06) : 517 - 522
  • [9] Simultaneous determination of paraquat and diquat in plasma and urine by ion chromatography-triple quadrupole mass spectrometry
    Zhang Xiuyao
    Cai Xinxin
    Zhang Xiaoyi
    Li Ruifen
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (11) : 1294 - 1301
  • [10] A sensitive and fast method for trihalomethanes in urine using gas chromatography-triple quadrupole mass spectrometry
    Charisiadis, Pantelis
    Makris, Konstantinos C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 17 - 22