Experimental Study on the Fire Performance of Tubular Steel Columns with Membrane Protections for Prefabricated and Modular Steel Construction

被引:7
|
作者
Zhang, Xin [1 ,2 ]
Peng, Lei [3 ]
Ni, Zhao-peng [3 ]
Ni, Tian-xiao [2 ]
Huang, Yi-liang [3 ]
Zhou, Yang [1 ]
机构
[1] Cent S Univ, Sch Civil Engn, Changsha 410075, Hunan, Peoples R China
[2] Changsha Kerich Fire Protect Engn Tech CO Ltd, Changsha 410007, Hunan, Peoples R China
[3] Minist Publ Secur, Tianjin Fire Res Inst, Tianjin 300381, Peoples R China
来源
MATERIALS | 2018年 / 11卷 / 03期
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
hollow structural section (HSS); steel tubular column; axial load; prefabricated and modular construction; membrane protection; RETARDANT COATING COMPOSITION; STRUCTURAL-STEEL; ELEVATED-TEMPERATURE;
D O I
10.3390/ma11030437
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Experimental research was conducted to study the fire resistance of steel tubular columns used in prefabricated and modular construction. In order to achieve high-efficient prefabrication and fast on-site installation, membrane protections using board products and thermal insulation blankets are adopted as the favorable protection method. Three protected tubular columns were tested in a full-scale column furnace with axial load applied. The study variables were different membranes, including fiber reinforced calcium silicate (FRCS) boards, rock wool and aluminum silica (Fiberfrax) insulations. The results suggest that one layer of 12 mm FRCS board with rock wool insulation has insufficient fire protection. However, steel columns protected with two layers of 12 mm FRCS boards with insulation appeared to have good fire resistances and could achieve a fire resistance rating as high as 2.5 similar to 3.0 h.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Experimental behaviour of steel connections to concrete filled steel tubular columns in fire
    Wang, Y. C.
    Ding, J.
    [J]. INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2007, 7 (03) : 201 - 208
  • [2] Experimental study on axial compression performance of partially prefabricated steel reinforced concrete columns after fire exposure
    Yang, Yong
    Xie, Yunyang
    Yu, Yunlong
    Zhang, Lin
    Xue, Yicong
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (09): : 91 - 100
  • [3] Experimental study on steel-reinforced concrete-filled steel tubular columns under the fire
    Mao, Wen-Jing
    Wang, Wen-Da
    Zhou, Kan
    Du, Er-Feng
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 185
  • [4] Fire performance of concrete filled stainless steel tubular columns
    Han, Lin-Hai
    Chen, Feng
    Liao, Fei-Yu
    Tao, Zhong
    Uy, Brian
    [J]. ENGINEERING STRUCTURES, 2013, 56 : 165 - 181
  • [5] Fire performance on steel-reinforced concrete-filled steel tubular columns with fire protection
    Mao, Wen-Jing
    Wang, Wen-Da
    Zhou, Kan
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199
  • [6] Fire performance of concrete filled steel tubular beam-columns
    Han, LH
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (06) : 695 - 709
  • [7] Fire Performance of Steel Tubular Columns Filled with Normal Strength Concrete
    Szymkuc, Wojciech
    Glema, Adam
    Malendowski, Michal
    [J]. RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 865 - 872
  • [8] Experimental study on the seismic performance of concrete filled steel tubular laced columns
    Huang, Zhi
    Jiang, Li-Zhong
    Chen, Y. Frank
    Luo, Yao
    Zhou, Wang-Bao
    [J]. STEEL AND COMPOSITE STRUCTURES, 2018, 26 (06): : 719 - 731
  • [9] Seismic performance of composite joints between prefabricated steel-reinforced concrete columns and steel beams: experimental study
    Wu Chenglong
    Liu Jiming
    Shi, Wei
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (08) : 3817 - 3841
  • [10] Experimental Study of Mechanical Behavior of Concrete Filled Steel Tubular Short Columns after Fire
    Zhou, Ming
    Wang, Xintang
    Wang, Wanzhen
    [J]. ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 168-170 : 674 - +