Biomechanical assessment of proximal junctional semi-rigid fixation in long-segment thoracolumbar constructs

被引:22
|
作者
Viswanathan, Vibhu K. [1 ]
Ganguly, Ranjit [1 ]
Minnema, Amy J. [1 ]
Watson, Nicole A. DeVries [4 ]
Grosland, Nicole M. [2 ,3 ,4 ]
Fredericks, Douglas C. [2 ]
Grossbach, Andrew J. [1 ]
Viljoen, Stephanus V. [1 ]
Farhadi, H. Francis [1 ]
机构
[1] Ohio State Univ, Wexner Med Ctr, Dept Neurol Surg, Columbus, OH 43210 USA
[2] Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA USA
[3] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[4] Univ Iowa, Ctr Comp Aided Design, Iowa City, IA USA
关键词
proximal junctional kyphosis; proximal junctional failure; sublaminar band; Mersilene tape; spinal deformity; thoracic; ADULT SPINAL DEFORMITY; THORACIC SPINE; RISK-FACTORS; ADJACENT SEGMENT; PEDICLE SCREW; KYPHOSIS; SURGERY; INSTRUMENTATION; OUTCOMES; TRANSITION;
D O I
10.3171/2018.7.SPINE18136
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Proximal junctional kyphosis (PJK) and failure (PJF) are potentially catastrophic complications that result from abrupt changes in stress across rigid instrumented and mobile non-fused segments of the spine (transition zone) after adult spinal deformity surgery. Recently, data have indicated that extension (widening) of the transitional zone via use of proximal junctional (PJ) semi-rigid fixation can mitigate this complication. To assess the biomechanical effectiveness of 3 semi-rigid fixation constructs (compared to pedicle screw fixation alone), the authors performed cadaveric studies that measured the extent of PJ motion and intradiscal pressure changes (Delta IDP). METHODS To measure flexibility and Delta IDP at the PJ segments, moments in flexion, extension, lateral bending (LB), and torsion were conducted in 13 fresh-frozen human cadaveric specimens. Five testing cycles were conducted, including intact (INT), T10-L2 pedicle screw-rod fixation alone (PSF), supplemental hybrid T9 Mersilene tape insertion (MT), hybrid T9 sublaminar band insertion (SLB1), and hybrid T8/T9 sublaminar band insertion (SLB2). RESULTS Compared to PSF, SLB1 significantly reduced flexibility at the level rostral to the upper-instrumented vertebral level (UIV+1) under moments in 3 directions (flexion, LB, and torsion, p <= 0.01). SLB2 significantly reduced motion in all directions at UIV+1 (flexion, extension, LB, torsion, p < 0.05) and at UIV+2 (LB, torsion, p <= 0.03). MT only reduced flexibility in extension at UIV+1 (p = 0.02). All 3 constructs revealed significant reductions in Delta IDP at UIV+1 in flexion (MT, SLB1, SLB2, p <= 0.02) and torsion (MT, SLB1, SLB2, p <== 0.05), while SLB1 and SLB2 significantly reduced Delta IDP in extension (SLB1, SLB2, p = 0.02) and SLB2 reduced Delta IDP in LB (p = 0.05). At UIV+2, SLB2 similarly significantly reduced Delta IDP in extension, LB, and torsion (p <= 0.05). CONCLUSIONS Compared to MT, the SLB1 and SLB2 constructs significantly reduced flexibility and Delta IDP in various directions through the application of robust anteroposterior force vectors at UIV+1 and UIV+2. These findings indicate that semi-rigid sublaminar banding can most effectively expand the transition zone and mitigate stresses at the PJ levels of long-segment thoracolumbar constructs.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条
  • [1] Biomechanical Assessment of a PEEK Rod System for Semi-Rigid Fixation of Lumbar Fusion Constructs
    Gornet, Matthew F.
    Chan, Frank W.
    Coleman, John C.
    Murrell, Brian
    Nockels, Russ P.
    Taylor, Brett A.
    Lanman, Todd H.
    Ochoa, Jorge A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (08):
  • [2] Biomechanical effects of osteoporosis severity on the occurrence of proximal junctional kyphosis following long-segment posterior thoracolumbar fusion
    Zhao, Gaiping
    He, Shenglan
    Chen, Eryun
    Ma, Tong
    Wu, Kunneng
    Wu, Jie
    Li, Weiqi
    Song, Chengli
    CLINICAL BIOMECHANICS, 2023, 110
  • [3] Topping-Off a Long Thoracic Stabilization With Semi-Rigid Constructs May Have Favorable Biomechanical Effects to Prevent Proximal Junctional Kyphosis: A Biomechanical Comparison
    Cadieux, Chloe
    Brzozowski, Pawel
    Fernandes, Renan J. R.
    McGregor, Martine E.
    Zdero, Radovan
    Bailey, Christopher S.
    McLachlin, Stewart D.
    Rasoulinejad, Parham
    GLOBAL SPINE JOURNAL, 2024,
  • [4] A biomechanical study on proximal junctional kyphosis following long-segment posterior spinal fusion
    Zhu, Wen-Yi
    Zang, Lei
    Li, Jian
    Guan, Li
    Hai, Yong
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2019, 52 (05)
  • [5] Risk factors for proximal junctional kyphosis after posterior long-segment internal fixation for chronic symptomatic osteoporotic thoracolumbar fractures with kyphosis
    Li, Qing-Da
    Yang, Jun-Song
    He, Bao-Rong
    Liu, Tuan-Jiang
    Gao, Lin
    Chai, Xin
    Tian, Xin
    Hao, Ding-Jun
    BMC SURGERY, 2022, 22 (01)
  • [6] Biomechanical evaluation of different semi-rigid junctional fixation techniques using finite element analysis
    van Agtmaal, Julia L.
    Doodkorte, Remco J. P.
    Roth, Alex K.
    Ito, Keita
    Arts, Jacobus J. C.
    Willems, Paul C.
    van Rietbergen, Bert
    CLINICAL BIOMECHANICS, 2023, 108
  • [7] Biomechanical Evaluation of Semi-rigid Junctional Fixation Using a Novel Cable Anchor System to Prevent Proximal Junctional Failure in Adult Spinal Deformity Surgery
    Doodkorte, Remco J. P.
    Roth, Alex K.
    Jacobs, Eva
    Arts, Jacobus J. C.
    Willems, Paul C.
    SPINE, 2022, 47 (09) : E415 - E422
  • [8] Risk factors for proximal junctional kyphosis after posterior long-segment internal fixation for chronic symptomatic osteoporotic thoracolumbar fractures with kyphosis
    Qing-Da Li
    Jun-Song Yang
    Bao-Rong He
    Tuan-Jiang Liu
    Lin Gao
    Xin Chai
    Xin Tian
    Ding-Jun Hao
    BMC Surgery, 22
  • [9] Proximal humeral fractures: what is semi-rigid? Biomechanical properties of semi-rigid implants, a biomechanical cadaver based evaluation
    Kralinger, F.
    Gschwentner, M.
    Wambacher, M.
    Smekal, V.
    Haid, C.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (02) : 205 - 210
  • [10] Proximal humeral fractures: what is semi-rigid? Biomechanical properties of semi-rigid implants, a biomechanical cadaver based evaluation
    F. Kralinger
    M. Gschwentner
    M. Wambacher
    V. Smekal
    C. Haid
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 205 - 210