Experimental research on applying the copper-clad aluminum tube as connecting tubes of air conditioners

被引:21
作者
Jin, Tingxiang [1 ]
Li, Gailian [1 ]
Cao, Yulong [1 ]
Xu, Ran [1 ]
Shao, Shuangquan [2 ,3 ]
Yang, Binbin [4 ]
机构
[1] Zhengzhou Univ Light Ind, Sch Energy & Power Engn, Zhengzhou 450002, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing Key Lab Thermal Sci & Technol, Beijing 100190, Peoples R China
[3] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Cryogen, Beijing 100190, Peoples R China
[4] Guangdong Chigo Air Conditioning CO LTD, Foshan 528244, Guangdong, Peoples R China
关键词
Copper-clad aluminum tube (CCA); Connecting tube; Air conditioner; EXTRUSION PROCESS; HYDROSTATIC EXTRUSION; INTERFACE; COMPOSITE;
D O I
10.1016/j.enbuild.2015.03.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes experimental investigation of copper-clad aluminum (CCA) tubing as a replacement for copper tubing to connect the indoor and outdoor units of split air conditioners. Experiments conducted on three specifications of CCA tubes (phi 6.35 x 0.6 mm(2), phi 9.52 x 0.7 mm(2), and phi 12.7 x 0.8 mm(2)) indicate good performance in terms of mechanical properties, processing properties, corrosion resistance, and pressure resistance; this means CCA tubes meet the installation and operation safety requirements for connecting tubes of air conditioners. Additionally, experimental results under two specifications air conditioners in cooling and heating conditions - reveal no obvious difference in cooling or heating performance when CCA tubes, instead of copper tubes, connect the indoor and outdoor units of air conditioners. Furthermore, compared to copper tubes, CCA tubes can reduce the weight by 36.5%-46.3% and the material cost by 23.0%-34.8%. There is great potential for weight and cost reduction in the widespread application of CCA tubing as the connecting tubes in air conditioners. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 17 条
  • [1] [Anonymous], 2004, 2422007 GBT
  • [2] [Anonymous], 2001, 92372001 GB
  • [3] [Anonymous], 1997, 101251997 GB
  • [4] [Anonymous], 2002, GB/T 228-2002
  • [5] Achieving better energy-efficient air conditioning - A review of technologies and strategies
    Chua, K. J.
    Chou, S. K.
    Yang, W. M.
    Yan, J.
    [J]. APPLIED ENERGY, 2013, 104 : 87 - 104
  • [6] Finite element simulation of die design for hot extrusion process of Al/Cu clad composite and its experimental investigation
    Kang, CG
    Jung, YJ
    Kwon, HC
    [J]. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2002, 124 (1-2) : 49 - 56
  • [7] Finite element analysis considering fracture strain of sheath material and die lubricant in extrusion process of Al/Cu clad composites and its experimental investigation
    Kang, CG
    Kwon, HC
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2002, 44 (02) : 247 - 267
  • [8] Investigation of parameters affecting interface strength in Al/Cu clad bimetal rod extrusion process
    Khosravifard, A.
    Ebrahimi, R.
    [J]. MATERIALS & DESIGN, 2010, 31 (01) : 493 - 499
  • [9] Bimetallic copper-aluminium tube by severe plastic deformation
    Lapovok, Rimma
    Ng, Hoi Pang
    Tomus, Dacian
    Estrin, Yuri
    [J]. SCRIPTA MATERIALIA, 2012, 66 (12) : 1081 - 1084
  • [10] Effect of bonding interface on delamination behavior of drawn Cu/Al bar clad material
    Lee, Sangmok
    Lee, Min-Geun
    Lee, Sang-Pill
    Lee, Geun-Ahn
    Kim, Yong-Bae
    Lee, Jong-Sup
    Bae, Dong-Su
    [J]. TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2012, 22 : S645 - S649