TAP WATER AND INDOOR AIR CONTAMINATION DUE TO AN UNINTENTIONAL CHEMICAL SPILL IN SOURCE WATER

被引:0
|
作者
Omur-Ozbek, Pinar [1 ]
Akalp, Duygu [2 ]
Whelton, Andrew [3 ]
机构
[1] Colorado State Univ, Dept Civil & Environm Engn, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Dept Construct Management, Ft Collins, CO 80523 USA
[3] Purdue Univ, Dept Civil Environm & Ecol Engn, Lafayette, IN USA
关键词
4-methylcyclohexane methanol (MCHM); Drinking water; Air quality modeling; West Virginia USA; Elk River spill; DRINKING-WATER; HUMAN EXPOSURE; WEST-VIRGINIA;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A chemical storage tank was found leaking into the Elk River, West Virginia, on January 9, 2014. The tank held similar to 10,000 gallons (38,000 L) of 4-methylcyclohexanemethanol ( MCHM). The chemical spilled 2.4 km away from the West Virginia American Water's (WVAW) Kanawha Valley Water Treatment Plant, traveling downstream and entering the treatment plant (50 MGD). West Virginia Poison Center started to get phone calls from the public, concerned about nausea, vomiting, diarrhea, rashes, and other symptoms. Simultaneously, the emergency departments observed an increase in the visit rates to emergency rooms, which were related to the above-mentioned symptoms. It was determined that the chemical spill ended up in the tap water and started affecting the people who used the tap water and inhaled the contaminated indoor air due to tap water use. This study employed available shower, tap water use at the sink, washing machine and dishwasher models and the reported tap water concentrations for the MCHM to determine the indoor air concentrations of MCHM. The results indicated that the exposure to hazardous levels of MCHM is most likely through showering and while during flushing out of the home plumbing. This study also considered natural and forced ventilation to provide guidance while flushing the home plumbing as it plays a critical role in indoor air concentrations of MCHM.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 50 条
  • [1] Residential tap water contamination following the freedom industries chemical spill: Perceptions, water quality, and health impacts
    Division of Environmental and Ecological Engineering, Lyles School of Civil Engineering, Purdue University, West Lafayette
    IN
    47907, United States
    不详
    AL
    36688, United States
    不详
    WV
    25301, United States
    不详
    AL
    36688, United States
    [J]. Environ. Sci. Technol., 2 (813-823):
  • [2] Residential Tap Water Contamination Following the Freedom Industries Chemical Spill: Perceptions, Water Quality, and Health Impacts
    Whelton, Andrew J.
    McMillan, LaKia
    Connell, Matt
    Kelley, Keven M.
    Gill, Jeff P.
    White, Kevin D.
    Gupta, Rahul
    Dey, Rajarshi
    Novy, Caroline
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (02) : 813 - 823
  • [3] Water contamination due to oil spill in Ancon
    Arce-Pizarro, Roselly Jasmin
    Arce-Pizarro, Jeremy Darlin
    Liñan-Romero, Alejandro Daniel
    Marín-Rodriguez, William Joel
    Andrade-Girón, Daniel Cristóbal
    de María Lioo-Jordán, Flor
    Caro-Soto, Félix Gil
    Calvo-Rivera, Irina Patricia
    [J]. EAI Endorsed Transactions on Energy Web, 2023, 10
  • [4] Tap water as a source of indoor radon in houses
    Klosok-Bazan, Iwona
    Boguniewicz-Zablocka, Joanna
    Naddeo, Vincenzo
    Domanowska, Alina
    [J]. 3RD SCIENTIFIC CONFERENCE ENVIRONMENTAL CHALLENGES IN CIVIL ENGINEERING (ECCE 2018), 2018, 174
  • [5] Water as a Source of Indoor Air Contamination with Potentially Pathogenic Aeromonas hydrophila in Aquaculture
    Golas, Iwona
    Szmyt, Mariusz
    Glinska-Lewczuk, Katarzyna
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [6] LEAD IN UMBILICAL BLOOD, INDOOR AIR, TAP WATER, AND GASOLINE IN BOSTON
    RABINOWITZ, M
    NEEDLEMAN, H
    BURLEY, M
    FINCH, H
    REES, J
    [J]. ARCHIVES OF ENVIRONMENTAL HEALTH, 1984, 39 (04): : 299 - 301
  • [7] Volatilization of chemicals from tap water to indoor air from contaminated water used for showering
    Moya, J
    Howard-Reed, C
    Corsi, RL
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (14) : 2321 - 2327
  • [8] The air/water syringe: a potential source of microbial contamination
    M V Martin
    [J]. British Dental Journal, 1998, 184 : 278 - 279
  • [9] The air/water syringe: A potential source of microbial contamination
    Martin, MV
    [J]. BRITISH DENTAL JOURNAL, 1998, 184 (06) : 278 - 279
  • [10] ALUMINUM CONTAMINATION OF TAP WATER AND FOOD
    KNOLL, O
    LAHL, H
    BOCKMANN, J
    HENNIG, H
    UNTERHALT, B
    [J]. TRACE ELEMENTS IN MEDICINE, 1986, 3 (04): : 172 - 175