Template-Based Correction of High-Order Aberration in Keratoconus

被引:10
|
作者
Marsack, Jason D. [1 ]
Rozema, Jos J. [2 ,3 ]
Koppen, Carina [2 ,3 ]
Tassignon, Marie-Jose [2 ,3 ]
Applegate, Raymond A. [1 ]
机构
[1] Univ Houston, Coll Optometry, Visual Opt Inst, Houston, TX 77204 USA
[2] Univ Antwerp Hosp, Dept Ophthalmol, Edegem, Belgium
[3] Univ Antwerp, Fac Med & Hlth Sci, Antwerp, Belgium
关键词
common optical correction; high-order aberration; keratoconus; Zernike; COLLABORATIVE LONGITUDINAL EVALUATION; CORNEAL TOPOGRAPHY; VISUAL PERFORMANCE; HEIGHT DATA; EYES; CLEK; ANTERIOR; SHAPE;
D O I
10.1097/OPX.0b013e318288c2b1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The common change in corneal morphology that is seen in keratoconus (KC) suggests the presence of common high-order aberration (HOA) structures and the potential for HOA corrections that apply to more than one eye. The purpose of this investigation is to classify a sample of KC eyes into subgroups based on similar HOA characteristics and simulate optical performance of common HOA corrections on members of each subgroup. Methods. High-order aberrations were recorded over a 5-mm pupil on 111 KC eyes. The eyes were divided into five subgroups based on observed commonality in HOA structure. From each subgroup, two eyes were removed for later evaluation of corrections. Principal components analysis was performed on the remaining eyes of each subgroup. The first principal component was scaled to form a set of corrections. Simulated optical correction of the test eyes was performed by identifying the magnitude of the inner-group correction providing the lowest level of residual higher order root mean square wavefront error (HORMS). Residual uncorrected HORMS was compared with levels found in uncorrected normal eyes and KC eyes wearing rigid gas-permeable corrections. Results. Ninety (81%) of the 111 eyes were included in one of the five subgroups. All 10 test eyes experienced a reduction in HORMS with a template correction compared with their uncorrected levels. Median HORMS reduced from uncorrected levels of 2.14 to 0.97 mu m. On average, the 10 subjects experienced a 51% reduction in HORMS (minimum, 16%; maximum, 81%; p < 0.01). When scaled to a 4-mm pupil, five of the 10 eyes experienced residual uncorrected HORMS within limits associated with gas-permeable wear. Conclusions. Overlap exists across these templates because of the dominance of vertical coma in the HOA structure. All eyes evaluated received reduced HORMS with a template-based correction. (Optom Vis Sci 2013;90:324-334)
引用
下载
收藏
页码:324 / 334
页数:11
相关论文
共 50 条
  • [1] The aberration correction of high-order Bessel-Gaussian beams
    Li, Jiaying
    Xie, Chen
    Qiu, Yuxuan
    Xiao, Na
    Hu, Minglie
    OPTIK, 2020, 221 (221):
  • [2] Influence of misalignment on high-order aberration correction for normal human eyes
    Zhao Hao-Xin
    Xu Bing
    Xue Li-Xia
    Dai Yun
    Liu Qian
    Rao Xue-Jun
    CHINESE PHYSICS LETTERS, 2008, 25 (04) : 1309 - 1312
  • [3] Aberration correction in holographic optical tweezers using a high-order optical vortex
    Liang, Yansheng
    Cai, Yanan
    Wang, Zhaojun
    Lei, Ming
    Cao, Zhiliang
    Wang, Yue
    Li, Manman
    Yan, Shaohui
    Bianco, Piero R.
    Yao, Baoli
    APPLIED OPTICS, 2018, 57 (13) : 3618 - 3623
  • [4] Design and fabrication of a freeform phase plate for high-order ocular aberration correction
    Yi, AY
    Raasch, TW
    APPLIED OPTICS, 2005, 44 (32) : 6869 - 6876
  • [5] Two-photon polymerization of femtosecond high-order Bessel beams with aberration correction
    Jia, Erse
    Xie, Chen
    Xiao, Na
    Courvoisier, Francois
    Hu, Minglie
    CHINESE OPTICS LETTERS, 2023, 21 (07)
  • [6] Two-photon polymerization of femtosecond high-order Bessel beams with aberration correction
    贾而穑
    谢辰
    肖娜
    Francois Courvoisier
    胡明列
    Chinese Optics Letters, 2023, 21 (07) : 26 - 31
  • [7] Accurate template-based correction technology for lens distortion
    Yang, Xieliu
    Fang, Suping
    Yang, Yulin
    OPTICAL ENGINEERING, 2012, 51 (10)
  • [8] The impact of misalignment on the optical and visual image quality of template-based corrections in keratoconus
    Rio, David
    Rozema, Jos J.
    Hastings, Gareth D.
    Marsack, Jason D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [9] Wavefront-customized soft contact lenses for high-order aberration correction in normal eyes
    Akers, Donnie
    Asimellis, George
    Karageorgiadis, Lefteris
    Katsoulos, Costas
    Vasileiou, Nikos
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [10] Design method of zoom systems based on high-order structural aberration coefficients
    Jipeng, Zhang
    Guangwei, Shi
    Haokun, Ye
    Yuqi, Huang
    Zhao, Shangnan
    Xin, Zhang
    Optics Express, 2024, 32 (21) : 36729 - 36741