摘要
The stability limit to the under-excited operation of synchronous generators is expressed in terms of two-axis reactances. These reactances have in the past generally been those applicable for rated load or corresponding with the short-circuit ratio. Modern large solid-rotor generators are heavily saturated and the use of these fixed reactances introduces error. Reactances appropriate to limiting operation are obtained here together with their derivatives with respect to load angle to give the limit. New limits for two large machines are presented. The new limits are more restrictive than when rated-load reactances are used but less restrictive than using those associated with the short-circuit ratio.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [1] Steady-state stability limit of turbine-generators in consideration of AVR
    Liu Qiang
    Li Yong-gang
    Li Hai-bo
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 125 - 128
  • [2] IEEE SCREENING GUIDE FOR PLANNED STEADY-STATE SWITCHING OPERATIONS TO MINIMIZE HARMFUL EFFECTS ON STEAM TURBINE-GENERATORS
    不详
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (04): : 1519 - 1521
  • [3] STEADY-STATE SHORT-CIRCUIT CHARACTERISTICS OF TURBINE-GENERATORS FROM DESIGN-DATA USING FIELD CALCULATIONS
    HANNALLA, AY
    MACDONALD, DC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (05): : 1805 - 1809
  • [4] EFFECTS OF UNBALANCED CURRENT ON TURBINE-GENERATORS
    KING, EI
    BATCHELOR, JW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (02): : 121 - +
  • [5] Steady-State Analysis and Stability of Synchronous Reluctance Motors Considering Saturation Effects
    Ibrahim, Mohamed. N.
    Rashad, Essam. M.
    Sergeant, Peter
    2015 IEEE 10TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2015, : 345 - 350
  • [6] LATE DISCUSSION OF EFFECTS OF UNBALANCED CURRENT ON TURBINE-GENERATORS
    ROSENBER.LT
    ROSS, MD
    KING, EI
    BATCHELO.JW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (06): : 484 - &
  • [7] STEADY-STATE STABILITY LIMIT IDENTIFICATION FOR LARGE POWER SYSTEMS
    Ciausiu, Florin
    Eremia, Mircea
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2010, 72 (01): : 201 - 209
  • [8] HIGH-RESPONSE EXCITATION SYSTEMS ON TURBINE-GENERATORS - A STABILITY ASSESSMENT
    HURLEY, JD
    BALDWIN, MS
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (11): : 4211 - 4221
  • [9] On observability of nonlinear steady-state generators
    Chen, Zhiyong
    AUTOMATICA, 2010, 46 (10) : 1712 - 1718
  • [10] Steady-state performance of synchronous generators with ac and dc stator connections considering saturation
    Wang, SM
    Wang, XG
    Li, YX
    Su, PS
    Ma, WM
    Zhang, GF
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (02) : 176 - 182