Visual performance of AcrySof ReSTOR apodized diffractive IOL: A prospective comparative trial

被引:146
|
作者
Souza, Carlos E. [1 ]
Muccioli, Cristina [1 ]
Soriano, Eduardo S. [1 ]
Chalita, Maria Regina [1 ]
Oliveira, Filipi [1 ]
Freitas, Lincoln L. [1 ]
Meire, Luci P. [1 ]
Tamaki, Celina [1 ]
Belfort, Rubens, Jr. [1 ]
机构
[1] Univ Fed Sao Paulo, Vis Inst, Sao Paulo, Brazil
关键词
D O I
10.1016/j.ajo.2005.12.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: Evaluate the visual performance of the AcrySof ReSTOR intraocular lens (IOL) and compare it with the monofocal SA60AT IOL. DESIGN: Prospective, nonrandomized, clinical trial. METHODS: Forty patients (80 eyes) from the Federal University of Sao Paulo were enrolled in two groups. Twenty-five patients were assigned to the ReSTOR group and 15 patients to the monofocal group. Inclusion criteria were corneal astigmatism < 1.0 diopter, potential acuity meter > 0.2 logMAR units, and no associated ocular diseases. Parameters analyzed included distance uncorrected and best-corrected visual acuity, near uncork rected and distance corrected visual acuity, intermediate visual acuity, contrast sensitivity (Pelli-Robson chart), stereopsis (Titmus test), reading speed, wavefront measurement (LADARWave aberrometer), and a quality-of-life questionnaire. MAIN OUTCOME MEASURE: Distance and near uncorrected and best distance corrected visual acuity, contrast sensitivity, and reading speed. RESULTS: Distance uncorrected and best-corrected visual acuity in the ReSTOR group were not statistically different from the monofocal group (P = .66). Near uncorrected and distance corrected visual acuity were statistically better in the ReSTOR group than the monofocal group (0.16 +/- 0.13 vs 0.62 +/- 0.09, P < .001, and 0.14 +/- 0.12 vs 0.62 +/- 0.07, P < .001, respectively). The ReSTOR group demonstrated less spherical aberrations compared with the monofocal group (P < .001). Monocular photopic contrast sensitivity was statistically lower in the ReSTOR group (P < .001). Stereopsis and reading speed were not statistically different between the groups. CONCLUSION: The AcrySof ReSTOR IOL provides a satisfactory full range of vision and achieves a more satisfactory quality of life when compared with the monofocal SA60AT IOL, but with lower contrast sensitivity.
引用
收藏
页码:827 / 832
页数:6
相关论文
共 50 条
  • [1] Visual performance of the acrysof restor multifocal IOL
    Souza, CE
    Soriano, ES
    Freitas, LL
    Muccioli, C
    Belfort, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [2] European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens
    Kohnen, T
    Allen, D
    Boureau, C
    Dublineau, P
    Hartmann, C
    Mehdorn, E
    Rozot, P
    Tassinari, G
    OPHTHALMOLOGY, 2006, 113 (04) : 578 - 584
  • [3] Subjective and objective outcome following implantation of the apodized diffractive AcrySof ReSTOR
    Petermeier, K.
    Szurman, R.
    OPHTHALMOLOGE, 2007, 104 (05): : 399 - +
  • [4] Visual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses
    Vingolo, Enzo Maria
    Grenga, PierLuigi
    Iacobelli, Luca
    Grenga, Roberto
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07): : 1244 - 1247
  • [5] Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Orti, Susana
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (02) : 333 - 339
  • [6] Does the apodized diffractive intraocular lens Acrysof ReSTOR Natural™ interfere with FDT Matrix perimetry results?
    Bojikian, Karine Duarte
    Vita, Joao Brasil
    Dal Forno, Catia Potira
    Tranjan Neto, Alfredo
    de Moura, Christiane Rolim
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (06) : 755 - 759
  • [7] Comparison of the Visual and Intraocular Optical Performance of a Refractive Multifocal IOL With Rotational Asymmetry and an Apodized Diffractive Multifocal IOL
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Javaloy, Jaime
    Ayala, Maria Jose
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (02) : 100 - U84
  • [8] Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs
    Rocha, KM
    Chalita, MR
    Souza, CEB
    Soriano, ES
    Freitas, LL
    Muccioli, C
    Belfort, R
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (06) : S808 - S812
  • [9] Refractive and visual results after implantation of the AcrySof ReSTOR IOL in high and low hyperopic eyes
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Orti, Susana
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (05) : 748 - 753
  • [10] Subjektive und objektive Ergebnisse nach Implantation der apodisiert diffraktiven AcrySof ReSTORSubjective and objective outcome following implantation of the apodized diffractive AcrySof ReSTOR
    K. Petermeier
    P. Szurman
    Der Ophthalmologe, 2007, 104 : 399 - 408