Testing and modeling of square carbon fiber-reinforced elastomeric seismic isolators

被引:154
|
作者
Toopchi-Nezhad, Hamid [1 ]
Tait, Michael J. [1 ]
Drysdale, Robert G. [1 ]
机构
[1] McMaster Univ, Dept Civil Engn, Hamilton, ON L8S 4L7, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
base isolation; earthquake hazard mitigation; fiber-reinforced elastomeric isolators; laminated rubber bearing; cyclic testing;
D O I
10.1002/stc.225
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-reinforced elastomeric isolators (SREIs), as an effective seismic isolation device, are the most common isolators in use. However, SREIs are typically heavy and expensive and, as a result, application of these devices is often limited to large and expensive structures. A reduction in the cost and weight of elastomeric isolators would permit a significant increase in their application to many ordinary residential and commercial buildings. Fiber-reinforced elastomeric isolators (FREIs) are a new type of elastomeric bearing that employs fiber as the reinforcement material rather than steel. FREIs have several advantages over traditional SREIs including superior damping properties, lower manufacturing cost, light weight, and the possibility of being produced in long rectangular strips with individual isolators cut to the required size. This paper presents a brief literature review on experiments with FREIs, and reports on an experimental study conducted on carbon FREIs from which the mechanical properties of the bearings, including displacement characteristics and damping values are evaluated. A brief description of an analytical approach to model the cyclic response of the bearings is another component of this paper. As a special application, the bearings considered in this study were not bonded to the test platens. For bearings having suitable aspect ratio values, this particular type of application resulted in a stable rollover deformation, which reduced the horizontal stiffness and increased the efficiency of the bearing as a seismic isolator device. Test results suggest that for many high seismic risk regions worldwide, the application considered in this study can be viable for the base isolation of ordinary low-rise buildings. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:876 / 900
页数:25
相关论文
共 50 条
  • [1] Fiber-reinforced elastomeric isolators: A review
    Van Engelen, Niel C.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 125
  • [2] Seismic Isolation of a Shear Wall Structure Using Rectangular Fiber-Reinforced Elastomeric Isolators
    Osgooei, Peyman M.
    Tait, Michael J.
    Konstantinidis, Dimitrios
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (02)
  • [3] Phenomenological modeling of fiber-reinforced elastomeric isolators at multiple lateral deformation levels
    Montalto, Eduardo J.
    Konstantinidis, Dimitrios
    Ankem, Neerav M.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (11): : 3335 - 3357
  • [4] Fiber reinforced elastomeric isolators for the seismic isolation of bridges
    Al-Anany, Yasser M.
    Tait, Michael J.
    COMPOSITE STRUCTURES, 2017, 160 : 300 - 311
  • [5] Vertical and Lateral Behavior of Unbonded Fiber-Reinforced Elastomeric Isolators
    Al-Anany, Yasser M.
    Van Engelen, Niel C.
    Tait, Michael J.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (05)
  • [6] Effect of Temperature on the Response of Unbonded Fiber-Reinforced Elastomeric Isolators
    Sciascetti, Alexander
    Tait, Michael
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (11)
  • [7] Modeling and Evaluation of a Seismically Isolated Bridge Using Unbonded Fiber-Reinforced Elastomeric Isolators
    Al-Anany, Yasser M.
    Moustafa, Mohamed A.
    Tait, Michael J.
    EARTHQUAKE SPECTRA, 2018, 34 (01) : 145 - 168
  • [8] Sliding instability of fiber-reinforced elastomeric isolators in unbonded applications
    Russo, Gaetano
    Pauletta, Margherita
    ENGINEERING STRUCTURES, 2013, 48 : 70 - 80
  • [9] Analysis of fiber-reinforced elastomeric isolators under pure "warping"
    Pinarbasi, Seval
    Mengi, Yalcin
    STRUCTURAL ENGINEERING AND MECHANICS, 2017, 61 (01) : 31 - 47
  • [10] Unbonded Fiber-Reinforced Elastomeric Isolators for Isolating Masonry Buildings
    Prakash, Shiv
    Jangid, R. S.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2024, 29 (02)