A Flexible Annular-Array Imaging Platform for Micro-Ultrasound

被引:18
|
作者
Qiu, Weibao [1 ,2 ]
Yu, Yanyan [2 ]
Chabok, Hamid Reza [3 ,4 ]
Liu, Cheng [2 ]
Tsang, Fu Keung [2 ]
Zhou, Qifa [3 ,4 ]
Shung, K. Kirk [3 ,4 ]
Zheng, Hairong [1 ]
Sun, Lei [2 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Inst Biomed & Hlth Engn, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen, Peoples R China
[2] Hong Kong Polytech Univ, Interdisciplinary Div Biomed Engn, Hong Kong, Hong Kong, Peoples R China
[3] Univ So Calif, Natl Inst Hlth NIH Resource Ctr Med Ultrason Tran, Los Angeles, CA USA
[4] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
基金
美国国家卫生研究院;
关键词
HIGH-FREQUENCY ULTRASOUND; IN-VIVO; DIGITAL BEAMFORMER; LINEAR-ARRAY; ARMY TRANSDUCER; 1-3; COMPOSITE; BIOMICROSCOPY; SYSTEM; DESIGN; FABRICATION;
D O I
10.1109/TUFFC.2013.2548
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Micro-ultrasound is an invaluable imaging tool for many clinical and preclinical applications requiring high resolution (approximately several tens of micrometers). Imaging systems for micro-ultrasound, including single-element imaging systems and linear-array imaging systems, have been developed extensively in recent years. Single-element systems are cheaper, but linear-array systems give much better image quality at a higher expense. Annular-array-based systems provide a third alternative, striking a balance between image quality and expense. This paper presents the development of a novel programmable and real-time annular-array imaging platform for micro-ultrasound. It supports multi-channel dynamic beamforming techniques for large-depth-of-field imaging. The major image processing algorithms were achieved by a novel field-programmable gate array technology for high speed and flexibility. Real-time imaging was achieved by fast processing algorithms and high-speed data transfer interface. The platform utilizes a printed circuit board scheme incorporating state-of-the-art electronics for compactness and cost effectiveness. Extensive tests including hardware, algorithms, wire phantom, and tissue mimicking phantom measurements were conducted to demonstrate good performance of the platform. The calculated contrast-to-noise ratio (CNR) of the tissue phantom measurements were higher than 1.2 in the range of 3.8 to 8.7 mm imaging depth. The platform supported more than 25 images per second for real-time image acquisition. The depth-of-field had about 2.5-fold improvement compared to single-element transducer imaging.
引用
收藏
页码:178 / 186
页数:9
相关论文
共 50 条
  • [1] A Flexible Annular Array Imaging Platform for Micro-Ultrasound
    Qiu, Weibao
    Yu, Yanyan
    Chabok, Hamid Reza
    Liu, Cheng
    Zhou, Qifa
    Shung, K. Kirk
    Zheng, Hairong
    Sun, Lei
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2172 - 2175
  • [2] Micro-ultrasound for preclinical imaging
    Foster, F. Stuart
    Hossack, John
    Adamson, S. Lee
    [J]. INTERFACE FOCUS, 2011, 1 (04) : 576 - 601
  • [3] High-frequency ultrasound annular-array imaging. Part I: Array design and fabrication
    Snook, KA
    Hu, CH
    Shrout, TR
    Shung, KK
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) : 300 - 308
  • [4] NONLINEAR CONTRAST IMAGING WITH AN ARRAY-BASED MICRO-ULTRASOUND SYSTEM
    Needles, A.
    Arditi, M.
    Rognin, N. G.
    Mehi, J.
    Coulthard, T.
    Bilan-Tracey, C.
    Gaud, E.
    Frinking, P.
    Hirson, D.
    Foster, F. S.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (12): : 2097 - 2106
  • [5] Physics and applications of preclinical micro-ultrasound imaging
    Foster, S
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2097 - 2097
  • [6] A Modulated Excitation Imaging System for Micro-ultrasound
    Qiu, Weibao
    Yu, Yanyan
    Li, Guofeng
    Qian, Ming
    Zheng, Hairong
    Sun, Lei
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 2042 - 2044
  • [7] Synthetic-Focusing Strategies for Real-Time Annular-Array Imaging
    Ketterling, Jeffrey A.
    Filoux, Erwan
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (08) : 1830 - 1839
  • [8] Prostatic high resolution micro-ultrasound (MUS) imaging
    Gregorio Pereira-Arias, Jose
    Sanchez-Vazquez, Andrea
    Gamarra-Quintanilla, Mikel
    Alberto Mora-Christian, Jorge
    Felipe Urdaneta-Solegui, Luis
    Astobieta-Odriozola, Ander
    Ibarluzea-Gonzalez, Gaspar
    [J]. ARCHIVOS ESPANOLES DE UROLOGIA, 2019, 72 (08): : 804 - 815
  • [9] Next generation micro-ultrasound for preclincal cancer imaging
    Foster, F.
    Lukacs, Marc
    Hirson, Desmond
    Mehi, James
    Chaggares, Chris
    White, Chris
    Needles, Andrew
    [J]. CANCER RESEARCH, 2009, 69
  • [10] Functional micro-ultrasound imaging of rodent cerebral hemodynamics
    van Raaij, Martijn E.
    Lindvere, Liis
    Dorr, Adrienne
    He, Jianfei
    Sahota, Bhupinder
    Foster, F. Stuart
    Stefanovic, Bojana
    [J]. NEUROIMAGE, 2011, 58 (01) : 100 - 108