Measurement of temperature gradient in a stack of a prime mover in a loop-tube-type thermoacoustic cooling system

被引:0
|
作者
Sakamoto, Shin-ichi [1 ]
Inui, Yoshitaka [1 ]
Watanabe, Yoshiaki [2 ]
机构
[1] Univ Shiga Prefecture, 2500 Hassaka, Hikone, Shiga 5228533, Japan
[2] Doshisha Univ, Kyoto 6100321, Japan
关键词
Thermoacoustic; Temperature gradient; Prime mover; STIRLING ENGINE; HEAT ENGINE; COOLER;
D O I
10.1063/1.4749356
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper specifically describes spatial and temporal variation of the temperature gradient in a stack of a prime mover in a loop-tube-type thermoacoustic cooling system. Spatial and temporal variations in the temperature gradient were measured for various stack lengths. Measurements were also conducted in cases with and without self-sustained sound. Because the thermal and viscous boundary-layer thicknesses depend on the temperature, detailed knowledge of spatial and temporal variations of the temperature gradient in the stack will be important to design a stack, especially in terms of the stack channel radius. Because little has been reported about the temperature gradient formed in the stack, the results obtained in these experiments are expected to contribute to improvement of the cooling effect of thermoacoustic cooling systems. Observations of the temperature variation in cases with and without self-sustained sound in the loop-tube confirmed that with self-sustained sound, a temperature gradient is formed linearly along the stack, which resulted from the heat flow caused by the thermoacoustic effect.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 27 条
  • [21] Effect of stack channel radius on the cooling performance of a thermoacoustic cooling system with diameter-expanded prime movers
    Ueno, So
    Sakamoto, Shin-ichi
    Orino, Yuichiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [22] Effect of expanded part length on quality value in straight-tube-type thermoacoustic system with a diameter-expanded prime mover
    Egawa, Kohei
    Sakamoto, Shin-ichi
    Orino, Yuichiro
    Yamaga, Yuya
    Inui, Kenshiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (07)
  • [23] Study on energy conversion in travelling wave type thermoacoustic system investigation on temperature distribution in the stack
    Kawashima, Yuto
    Sakamoto, Shin-ichi
    Kuroki, Daichi
    Shiraki, Kazuki
    Kurata, Yuya
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (59)
  • [24] Advanced exergy investigation of a combined cooling and power system with low-temperature geothermal heat as a prime mover for district cooling applications
    Mohammadi, Zahra
    Musharavati, Farayi
    Ahmadi, Pouria
    Rahimi, Shayan
    Khanmohammadi, Shoaib
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
  • [25] Variable temperature system using vortex tube cooling and fiber optic temperature measurement for low temperature magic angle spinning NMR
    Martin, RW
    Zilm, KW
    JOURNAL OF MAGNETIC RESONANCE, 2004, 168 (02) : 202 - 209
  • [26] Differences in temperature measurement by commercial room temperature sensors: Effects of room cooling system, loads, sensor type and position
    Shinoda, Jun
    Mylonas, Angelos
    Kazanci, Ongun B.
    Tanabe, Shin-ichi
    Olesen, Bjarne W.
    ENERGY AND BUILDINGS, 2021, 231
  • [27] Controlling of loop-tube type thermoacoustic system using heat phase adjuster examination of the control mechanism using a physical model of the heat phase adjuster
    Shiraki, Kazuki
    Sakamoto, Shin-ichi
    Kurata, Yuya
    Kawashima, Yuto
    Onishi, Riku
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (59)