RADIATION TOLERANCE LIMITS OF THE BRAINSTEM

被引:60
|
作者
Sharma, Manish S. [2 ]
Kondziolka, Douglas [1 ]
Khan, Aftaab
Kano, Hideyuki
Niranjan, Ajay
Flickinger, John C. [3 ]
Lunsford, L. Dade
机构
[1] Univ Pittsburgh, UPMC, Med Ctr, Dept Neurol Surg, Pittsburgh, PA 15213 USA
[2] All India Inst Med Sci, Dept Neurosurg, New Delhi, India
[3] Univ Pittsburgh, Med Ctr, Dept Radiat Oncol, Pittsburgh, PA 15213 USA
关键词
Adverse radiation effect; Brainstem; Gamma knife; Radiation; Safety; Stereotactic surgery; Tolerance;
D O I
10.1227/01.NEU.0000325726.72815.22
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: One of the key limitations of gamma knife surgery arises from the radiation safety tolerance limit of the brainstem. The authors conducted an analysis of patients with intra-axial brainstem lesions and documented the incidence of adverse ratiation imaging effects (ARIE) and new neurological deficits after gamma knife surgery. METHODS: Thirty-eight patients (39 lesions) with intra-axial brainstem astrocytomas or vascular malformations underwent gamma knife surgery during a 6-year interval. Brainstem exposure volume was calculated by subtracting the volume within the 12-Gy isodose line (12 Gray volume) from the prescription volume. ARIE was defined as a new parenchymal signal alteration on follow-up magnetic resonance imaging sequences. RESULTS: The average prescription volume was 1.46 cm(3), 12 Gy volumes was 2.03 cm(3), and brainstem exposure volume was 0.57 cm(3). Seven (18.4%) patients developed ARIE. ARIE correlated only with the presence of new neurological deficits and age younger than 40 years. Three (7.9%) patients developed minor residual deficits without any ARIE. There was no mortality. CONCLUSION: Exposure of the brainstem to more than 12 Gy at volumes as low as 0.1 cm(3) can produce ARIE and new neurological deficits. The tolerance of the brainstem to radiosurgery is related to patient age, lesion volume, and pathology. Analysis of the exposed volume of brainstem tissue may be useful in radiosurgical planning for individual patients.
引用
收藏
页码:728 / 732
页数:5
相关论文
共 50 条
  • [1] RADIATION TOLERANCE LIMITS OF THE BRAINSTEM COMMENTS
    Chang, Steven D.
    Sheehan, Jason P.
    Loeffler, Jay S.
    NEUROSURGERY, 2008, 63 (04) : 733 - 733
  • [2] The Tolerance of Brainstem in Reirradiation With Intensity Modulated Radiation Therapy in Recurrent Nasopharyngeal Carcinoma
    Wang, H. Z.
    Luo, J. W.
    Yi, J. L.
    Huang, X. D.
    Zhang, S. P.
    Wang, K.
    Qu, Y.
    Xiao, J. P.
    Li, S. Y.
    Gao, L.
    Xu, G. Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E340 - E340
  • [3] Radiation therapy tolerance limits - For one or for all? Janeway lecture
    Peters, LJ
    CANCER, 1996, 77 (11) : 2379 - 2385
  • [4] Fractionated Stereotactic Radiosurgery for Brainstem Metastasis and Brainstem Tolerance
    Chen, X.
    Grimm, J.
    Baker, B. R.
    Son, J.
    Siu, C.
    Redmond, K. J.
    Bettegowda, C.
    Lim, M.
    Kleinberg, L. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E72 - E73
  • [5] Limits of Tolerance?
    Buddeberg, Eva
    PHILOSOPHISCHES JAHRBUCH, 2022, 129 (02): : 234 - 249
  • [6] THE LIMITS OF TOLERANCE
    不详
    ECONOMIST, 1956, 178 (11): : 607 - 607
  • [7] Tolerance Limits
    Soo-young, Kim
    SPACE, 2022, (656): : 60 - 65
  • [8] Limits of tolerance
    Bystrov, V. Yu
    VESTNIK SANKT-PETERBURGSKOGO UNIVERSITETA-FILOSOFIYA I KONFLIKTOLOGIYA, 2020, 36 (01): : 24 - 34
  • [9] Brainstem tolerance to spot-scanning proton radiation therapy for chordoma and chondrosarcoma of the skull base
    Ares, C.
    Lomax, A. J.
    Weber, D. C.
    Stadelmann, O.
    Rutz, H. P.
    Timmermann, B.
    Bolsi, A.
    Verwey, J.
    Goitein, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 172 - 172
  • [10] PEDIATRIC BRAINSTEM TOLERANCE TO PROTON THERAPY
    Indelicato, Daniel
    Rotondo, Ronny
    Bradley, Julie
    Sandler, Eric
    Aldana, Philipp
    Flampouri, Stella
    Mendenhall, Nancy
    PEDIATRIC BLOOD & CANCER, 2013, 60 : S70 - S70