Lattice modification and nonlinear dynamics for elliptically polarized VUVOK-5FEL source at Duke storage ring

被引:8
|
作者
Wu, Y
Litvinenko, VN
Mikhailov, SF
Shevchenko, OA
Vinokurov, NA
Gavrilov, NG
Shaftan, TV
Kairan, DA
机构
[1] Duke Univ, Dept Phys, FEL Lab, Durham, NC 27708 USA
[2] Budker Inst Nucl Phys, Novosibirsk 630090, Russia
[3] Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
storage ring; FEL; dynamic aperture; Wiggler;
D O I
10.1016/S0168-9002(01)01567-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Duke storage ring is a light source ring optimized for driving the Free Electron Lasers (FELs). To take advantage of the high brightness of the electron beam in the storage ring, a next generation FEL source - an elliptically polarized OK-5 FEL system, has been designed to match the electron beam quality of the Duke storage ring. In this paper, we present the storage ring lattice modifications which are necessary to accommodate the 24 m long OK-5 FEL. Because of its length and strong nonlinear focusing, the OK-5 FEL is expected to have a significant impact on the electron beam dynamics. We also present the preliminary results on the dynamic aperture calculation for the OK-5 FEL operated in different modes. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 17 条
  • [1] Nonlinear dynamics in the duke storage ring with FEL wigglers
    Wu, YK
    Li, J
    Mikhailov, SF
    Litvinenko, V
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 391 - 393
  • [2] Predictions and expected performance for the VUVOK-5/Duke storage ring FEL with variable polarization
    Litvinenko, VN
    Shevchenko, OA
    Vinokurov, NA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 475 (1-3): : 97 - 103
  • [3] DYNAMICS OF THE DUKE STORAGE-RING UV FEL
    LITVINENKO, VN
    BURNHAM, B
    MADEY, JMJ
    WU, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 358 (1-3): : 369 - 373
  • [4] Low emittance lattice for the Duke storage ring soft X-ray FEL
    Mikhailov, SF
    Litvinenko, VN
    Wu, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 475 (1-3): : 417 - 424
  • [5] Intense Compton gamma-ray source from the Duke storage ring FEL
    Litvinenko, VN
    Madey, JMJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 375 (1-3): : 580 - 583
  • [6] Unique features of the OK-4/Duke storage ring XUV FEL and monochromatic γ-ray source
    Litvinenko, V.N.
    Wu, Y.
    Burnham, B.
    Park, S.H.
    Emamian, M.
    Faircloth, J.
    Goetz, S.
    Hower, N.
    Madey, J.M.J.
    Meyer, J.
    Morcombe, P.
    Oakeley, O.
    Patterson, J.
    Sachtschale, R.
    Swift, G.
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 1 : 883 - 885
  • [7] Unique features of the OK-4/Duke storage ring XUV FEL and monochromatic γ-ray source.
    Litvinenko, VN
    Wu, Y
    Burnham, B
    Park, SH
    Emamian, M
    Faircloth, J
    Goetz, S
    Hower, N
    Madey, JMJ
    Meyer, J
    Morcombe, P
    Oakeley, O
    Patterson, J
    Sachtschale, R
    Swift, G
    Wang, P
    Pinayev, IV
    Fedotov, MG
    Gavrilov, NG
    Popik, VM
    Repkov, VN
    Isaeva, LG
    Kulipanov, GN
    Kurkin, GY
    Mikhailov, SF
    Skrinsky, AN
    Vinokurov, NA
    Vobly, PD
    Zinin, EI
    Lumpkin, A
    Yang, B
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 883 - 885
  • [8] Modification and optimization of the storage ring lattice of the High Energy Photon Source
    Jiao, Yi
    Chen, Fusan
    He, Ping
    Li, Chunhua
    Li, Jingyi
    Qin, Qing
    Qu, Huamin
    Wan, Jinyu
    Wang, Jiuqing
    Xu, Gang
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2020, 4 (04) : 415 - 424
  • [9] Modification and optimization of the storage ring lattice of the High Energy Photon Source
    Yi Jiao
    Fusan Chen
    Ping He
    Chunhua Li
    Jingyi Li
    Qing Qin
    Huamin Qu
    Jinyu Wan
    Jiuqing Wang
    Gang Xu
    Radiation Detection Technology and Methods, 2020, 4 : 415 - 424
  • [10] MM-WAVE ISOCHRONOUS FEL AND HARD X-RAY INVERSE COMPTON SOURCE AT THE DUKE STORAGE-RING
    LITVINENKO, VN
    WU, Y
    BURNHAM, B
    BARNETT, G
    MADEY, JMJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 358 (1-3): : 345 - 348