Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation for 3D PET

被引:0
|
作者
Ye, Jinghan [1 ]
Song, Xiyun [1 ]
Hu, Zhiqiang [2 ]
机构
[1] Philips Healthcare, San Jose, CA 95134 USA
[2] Philips Healthcare, Cleveland, OH USA
关键词
PET; scatter correction; Monte Carlo; single-scatter simulation;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In positron emission tomography (PET) imaging, scattered gamma photons typically account for more than 30% of total detected coincidence counts. Single scatter simulation (SSS) method is widely used for estimating scatter contribution in PET image reconstruction. Monte Carlo (MC) techniques are more accurate but computationally expensive. When using SSS, the modeled scatter contribution is typically scaled to match the measured data. Typically tail fitting is used for this scaling. However, when the available tail part is either too small or too noisy, the tail fitting technique may lead to artifacts in the reconstructed images. In this study, a hybrid method that combines SSS and MC is presented. The method uses SSS to approximate the shape of scatter contribution, and scales the SSS result by a scaling factor derived from a low-count MC simulation. Effectiveness of the method is evaluated with phantom and patient studies. Images reconstructed using SSS with tail-fitting scaling (SSS-TFS) and SSS with Monte Carlo scaling (SSS-MCS) are compared. Results show that SSS-MCS significantly reduces or eliminates the artifacts that present in SSS-TFS images. For smaller objects, both SSS-MCS and SSS-TFS produce artifact-free images. The MC simulation takes less than a second on a computer with 8 CPU cores to achieve less than 1% of scatter scaling factor variation. A hybrid scatter correction method that combines SSS and Monte Carlo simulation is developed for PET reconstruction. The method demonstrates a significant improvement in scatter correction accuracy. The added computational cost is negligible.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Comparison of Single-Scatter Simulation and Monte Carlo Single-Scatter Simulation on Philips Ingenuity TF PET/MR
    Teuho, Jarmo
    Johansson, Jarkko
    Linden, Jani
    Saunavaara, Virva
    Teras, Mika
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] A single scatter simulation technique for scatter correction in 3D pet
    Watson, CC
    Newport, D
    Casey, ME
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 255 - 268
  • [3] Validation of scatter correction with combined single-scatter simulation and Monte Carlo simulation scaling to quantify myocardial blood flow on 15O-water PET
    Magota, Keiichi
    Shiga, Tohru
    Manabe, Osamu
    Naya, Masanao
    Aikawa, Tadao
    Shinyama, Daiki
    Heijtel, Dennis
    Hirata, Kenji
    Katoh, Chietsugu
    Huisman, Marc
    Boellaard, Ronald
    Fujita, Katsuhisa
    Lammertsma, Adriaan
    Tamaki, Nagara
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [4] Investigation of accelerated Monte Carlo techniques for PET simulation and 3D PET scatter correction
    Holdsworth, CH
    Levin, CS
    Farquhar, TH
    Dahlbom, M
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 74 - 81
  • [5] A Monte-Carlo simulation study on coarse septa for scatter correction in 3D PET
    Hasegawa, T
    Tanaka, E
    Yamashita, T
    Watanabe, M
    Yamaya, T
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2110 - 2114
  • [6] Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation Scaling Improved the Visual Artifacts and Quantification in 3-Dimensional Brain PET/CT Imaging with 15O-Gas Inhalation
    Magota, Keiichi
    Shiga, Tohru
    Asano, Yukari
    Shinyama, Daiki
    Ye, Jinghan
    Perkins, Amy E.
    Maniawski, Piotr J.
    Toyonaga, Takuya
    Kobayashi, Kentaro
    Hirata, Kenji
    Katoh, Chietsugu
    Hattori, Naoya
    Tamaki, Nagara
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (12) : 2020 - 2025
  • [7] Investigation of accelerated monte carlo techniques for PET simulation and 3-D PET scatter correction
    Holdsworth, CH
    Levin, CS
    Farquhar, TH
    Dahlbom, M
    Hoffman, EJ
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1500 - 1504
  • [8] Performance analysis of an improved 3-D PET Monte Carlo simulation and scatter correction
    Holdsworth, CH
    Levin, CS
    Janecek, M
    Dahlbom, M
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 83 - 89
  • [9] A Monte Carlo simulation study on coarse septa for scatter correction in 3-D PET
    Hasegawa, T
    Tanaka, E
    Yamashita, T
    Watanabe, M
    Yamaya, T
    Murayama, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2133 - 2138
  • [10] Accelerated Monte Carlo Scatter Correction for 3D PET.
    Holdsworth, CH
    Levin, CS
    Dahlbom, M
    Farquhar, TH
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 195P - 195P