Computational evaluation of oxygen and shear stress distributions in 3D perfusion culture systems: Macro-scale and micro-structured models

被引:72
|
作者
Cioffi, M. [1 ,2 ,3 ]
Kueffer, J.
Stroebel, S. [2 ]
Dubini, G. [1 ]
Martin, I. [2 ]
Wendt, D. [2 ]
机构
[1] Politecn Milan, Dept Struct Engn, Lab Biol Struct Mech, I-20133 Milan, Italy
[2] Univ Basel Hosp, Dept Surg & Res, Basel, Switzerland
[3] Ist Ortaped Galeazzi, IRCCS, Milan, Italy
关键词
Tissue engineering; Micro-CT; Scaffold; Bioreactor; Computational fluid dynamics;
D O I
10.1016/j.jbiomech.2008.07.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a combined macro-scale/micro-scale computational approach to quantify oxygen transport and flow-mediated shear stress to human chondrocytes cultured in three-dimensional scaffolds in a perfusion bioreactor system. A macro-scale model was developed to assess the influence of the bioreactor design and to identify the proper boundary conditions for the micro-scale model. The microscale model based on a micro-computed tomography (pCT) reconstruction of a poly(ethylene glycol terephthalate)/poly(butylene terephthalate) (PEGT/PBT) foam scaffold, was developed to assess the influence of the scaffold micro-architecture on local shear stress and oxygen levels within the scaffold pores, Experiments were performed to derive specific oxygen consumption rates for constructs perfused under flow rates of 0.3 and 0.03 ml min(-1). While macro-scale and micro-scale models predicted similar average oxygen levels at different depths within the scaffold, mu CT models revealed small local oxygen variations within the scaffold micro-architecture. The combined macro-scale/micro-scale approach indicated that 0.3 ml min(-1), which subjected 95% of the cells to less than 6.3 mPa shear, would maintain the oxygen supply throughout the scaffold above anoxic levels (> 1%), with 99.5% of the scaffold supplied with 8-2% O-2. Alternatively, at 0.03 ml min(-1), the macro-scale model predicted 6% of the cells would be supplied with 0.5-1% O-2, although this region of cells was confined to the periphery of the scaffold. Together with local variations predicted by the micro-scale model, the simulations underline that in the current model system, reducing the flow below 0.03 ml min(-1) would likely have dire consequences on cell viability to pronounced regions within the engineered construct. The presented approach provides a sensitive tool to aid efficient bioreactor optimization and scaffold design. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2918 / 2925
页数:8
相关论文
共 12 条
  • [1] Mini- and macro-scale direct perfusion bioreactors with optimized flow for engineering 3D tissues
    Born, Gordian
    Plantier, Evelia
    Nannini, Guido
    Caimi, Alessandro
    Mazzoleni, Andrea
    Asnaghi, M. Adelaide
    Muraro, Manuele G.
    Scherberich, Arnaud
    Martin, Ivan
    Garcia-Garcia, Andres
    BIOTECHNOLOGY JOURNAL, 2023, 18 (02)
  • [2] Floating Micro-Structured Force Probe for 3D Imaging and Force Microscopy on the Nanometre Scale
    Towrie, M.
    Botchway, S. W.
    Clark, A. T.
    Freeman, E. J.
    Halsall, R. N. J.
    Jenkins, D. W. K.
    Loader, I. M.
    O'Neill, P.
    Parker, A. W.
    Prydderch, M. L.
    Stevens, R.
    Turchetta, R.
    Ward, A. D.
    Pollard, M.
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 386 - +
  • [3] Micro- and Macro-Scale Measurement of Flow Velocity in Porous Media: A Shadow Imaging Approach for 2D and 3D
    Sabbagh, Reza
    Kazemi, Mohammad Amin
    Soltani, Hirad
    Nobes, David S.
    OPTICS, 2020, 1 (01):
  • [4] Development of a micro-scale perfusion 3D cell culture biochip with an incorporated electrical impedance measurement scheme for the quantification of cell number in a 3D cell culture construct
    Lei, Kin Fong
    Wu, Min-Hsien
    Liao, Pei-You
    Chen, Yan-Ming
    Pan, Tung-Ming
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 12 (1-4) : 117 - 125
  • [5] Development of a micro-scale perfusion 3D cell culture biochip with an incorporated electrical impedance measurement scheme for the quantification of cell number in a 3D cell culture construct
    Kin Fong Lei
    Min-Hsien Wu
    Pei-You Liao
    Yan-Ming Chen
    Tung-Ming Pan
    Microfluidics and Nanofluidics, 2012, 12 : 117 - 125
  • [6] The evaluation of endoplasmic reticulum (ER) stress in steatotic hepatocytes under a new 3D perfusion culture system consistent with hepatic portal blood
    Kakazu, Eiji
    Inoue, Jun
    Kogure, Takayuki
    Ninomiya, Masashi
    Morosawa, Tatsuki
    Umetsu, Teruyuki
    Nakamura, takuya
    Takai, Satoshi
    Shimosegawa, Tooru
    HEPATOLOGY, 2016, 64 : 799A - 800A
  • [7] Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models
    LaDisa, JF
    Olson, LE
    Guler, I
    Hettrick, DA
    Kersten, JR
    Warltier, DC
    Pagel, PS
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (03) : 947 - 957
  • [8] Evaluation of endothelial shear stress and 3D geometry as factors determining the development of atherosclerosis and remodeling in human coronary arteries in vivo - Combining 3D reconstruction from angiography and IVUS (ANGUS) with computational fluid dynamics
    Krams, R
    Wentzel, JJ
    Oomen, JAF
    Vinke, R
    Schuurbiers, JCH
    deFeyter, PJ
    Serruys, PW
    Slager, CJ
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (10) : 2061 - 2065
  • [9] Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening
    LaDisa, John F., Jr.
    Olson, Lars E.
    Hettrick, Douglas A.
    Warltier, David C.
    Kersten, Judy R.
    Pagel, Paul S.
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [10] Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening
    John F LaDisa
    Lars E Olson
    Douglas A Hettrick
    David C Warltier
    Judy R Kersten
    Paul S Pagel
    BioMedical Engineering OnLine, 4