Techno-economic analysis of a stand-alone hybrid renewable energy system with hydrogen production and storage options

被引:247
|
作者
Kalinci, Yildiz [1 ]
Hepbasli, Arif [2 ]
Dincer, Ibrahim [3 ,4 ]
机构
[1] Dokuz Eylul Univ, Izmir Vocat High Sch, Dept Tech Programs, Izmir, Turkey
[2] Yasar Univ, Fac Engn, Dept Energy Syst Engn, TR-35100 Izmir, Turkey
[3] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7K4, Canada
[4] KFUPM, Dept Mech Engn, Dhahran 31261, Saudi Arabia
基金
加拿大自然科学与工程研究理事会;
关键词
Renewable energy; Cost assessment; Electricity; Hydrogen production; PEM FUEL-CELLS; ECONOMIC-ASSESSMENT; POWER MANAGEMENT; BATTERY SYSTEM; WIND SYSTEM; ISLAND; IMPLEMENTATION; TECHNOLOGIES; FEASIBILITY; SIMULATION;
D O I
10.1016/j.ijhydene.2014.10.147
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In the present study, a hybrid renewable energy system using hydrogen energy as energy storage option is conceptually modeled for the Bozcaada Island in Turkey. The system is investigated from the techno-economic point of view. The Hybrid Optimization Model for Electric Renewable (HOMER) tool is used to define the optimum size of the equipment based on the geographical and meteorological data of the island. The HOMER uses the net present cost (NPC) method while ranking the system suitability. Also, the cost of energy (COE) is calculated with the total annual cost (ACT). The study considers two scenarios, which are only wind turbine and wind turbine/PV hybrid systems. Using the wind turbine/PV array system, instead of wind turbine only, decreases the NPC from $14,624,343 to $11,960,698. Also, it decreases the hydrogen tank capacity to 400 kg and hence affects other equipment size and NPC. So, the COE varies between $1.016/kWh and $0.83/kWh. According to this, the optimum system components are defined as PV array-300 kW, wind turbine (E33x2), fuel cell-100 kW, converter-150 kW, electrolyzer-200 kW and hydrogen tank-400 kg to supply a 1875 kWh/d primary load. Furthermore, the effects of some parameters and the equipment on NPC are examined. Increasing potential of the renewable energy sources, such as annual average wind speed or solar radiation, decreases both COE and NPC. While the annual average solar radiation increases to 5 kWh/m(2)/d, the NPC and CUE decrease to $11,673,704 and $0.81/kWh. Likewise, an increase in the annual average wind speed will decrease the costs to $11,452,712 and $0.795/kWh, respectively. Also, increasing the real interest i, to 5% increases the COE to $1.043/kWh, as expected. Copyright (c) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:7652 / 7664
页数:13
相关论文
共 50 条
  • [1] Techno-economic optimization analysis of stand-alone renewable energy system for remote areas
    Akram, Fareeha
    Asghar, Furqan
    Majeed, Muhammad Asghar
    Amjad, Waseem
    Manzoor, M. Owais
    Munir, Anjum
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 38
  • [2] Control based on techno-economic optimization of renewable hybrid energy system for stand-alone applications
    Torreglosa, Juan P.
    Garcia-Trivino, Pablo
    Fernandez-Ramirez, Luis M.
    Jurado, Francisco
    [J]. EXPERT SYSTEMS WITH APPLICATIONS, 2016, 51 : 59 - 75
  • [3] Techno-economic Assessement of Hybrid Energy System for a Stand-Alone Load in Morocco
    El Haini, Jamila
    Saka, Abdelmjid
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2020, 10 (04): : 1774 - 1782
  • [4] Demand Side Management based techno-economic performance analysis for a stand-alone hybrid renewable energy system of India
    Ramesh, Mala
    Saini, Rajeshwer Prasad
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2020,
  • [5] Techno-economic analysis of the integration of hydrogen energy technologies in renewable energy-based stand-alone power systems
    Zoulias, E. I.
    Lymberopoulos, N.
    [J]. RENEWABLE ENERGY, 2007, 32 (04) : 680 - 696
  • [6] Techno-economic analysis of PV/wind turbine stand-alone energy system
    Simunovic, Jakov
    Barbir, Frano
    Radica, Gojmir
    Klarin, Branko
    [J]. 2019 4TH INTERNATIONAL CONFERENCE ON SMART AND SUSTAINABLE TECHNOLOGIES (SPLITECH), 2019, : 376 - 380
  • [7] Techno-economic Analysis of An Off Grid Hybrid Renewable Energy System for Hydrogen Production
    Tebibel, Hammou
    Khellaf, Abdallah
    [J]. PROCEEDINGS OF 2017 INTERNATIONAL RENEWABLE & SUSTAINABLE ENERGY CONFERENCE (IRSEC' 17), 2017, : 650 - 655
  • [8] Techno-Economic Analysis of a Stand-Alone Hybrid System: Application in Donoussa Island, Greece
    Katsivelakis, Michail
    Bargiotas, Dimitrios
    Daskalopulu, Aspassia
    Panapakidis, Ioannis P.
    Tsoukalas, Lefteri
    [J]. ENERGIES, 2021, 14 (07)
  • [9] Techno-economic investigation and dual-objective optimization of a stand-alone combined configuration for the generation and storage of electricity and hydrogen applying hybrid renewable system
    Dadak, Ali
    Mousavi, Seyed Ali
    Mehrpooya, Mehdi
    Kasaeian, Alibakhsh
    [J]. RENEWABLE ENERGY, 2022, 201 : 1 - 20
  • [10] Optimal hydrogen production in a stand-alone renewable energy system
    Agbossou, K
    Doumbia, ML
    Anouar, A
    [J]. CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 2932 - 2936