Integration of hydride generation and photochemical vapor generation for multi-element analysis of traditional Chinese medicine by ICP-OES

被引:31
|
作者
Shen, Yan [1 ]
Zheng, Chengbin [2 ]
Jiang, Xiaoming [1 ]
Wu, Xi [1 ]
Hou, Xiandeng [1 ,2 ]
机构
[1] Sichuan Univ, Analyt & Testing Ctr, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Chem, Chengdu 610064, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Hydride generation; Photochemical vapor generation; Inductively coupled plasma; Optical emission spectrometry; Traditional Chinese medicine; Trace toxic elements; FLUORESCENCE SPECTROMETRIC DETERMINATION; SAMPLE INTRODUCTION; CONVENTIONAL HYDRIDE; FORMING ELEMENTS; SE; SELENIUM; ACID; SN; BI; HG;
D O I
10.1016/j.microc.2015.06.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A dual-mode chemical vapor generation (DM-CVG) sample introduction system that integrates hydride generation (HG) and photochemical vapor generation (PVG) was coupled to a commercial inductively coupled plasma optical emission spectrometer (ICP-OES) for simultaneous multi-element analysis of traditional Chinese medicine samples for trace hydride-forming elements and non-hydride-forming elements. Three hydride-forming elements (Cd, As, and Ge) and two non-hydride-forming but photochemical vapor-generating elements (Co and Ni) were selected as target elements to validate the proposed method. Optimum experimental conditions for DM-CVG-ICP-OES were carefully investigated, and satisfactory limits of detection (LODs), 0.2-1.4 mu g L-1, and relative standard deviations (RSDs), 1.3%-4.6%, were obtained for these target elements. A certified reference celery sample (GBW10048) was used to investigate the feasibility of the proposed method for real analysis. Strong suppression on the PVG efficiency occurred either when little nitric acid residue or some unknown coexisting materials remained in the sample solutions. Complete acid-evaporation/catching and moderate dilution of the digests could effectively alleviate this negative effect. Four different acid-evaporation/catching methods were performed and compared. Catching acid by adding an appropriate volume of formic acid gave the best signal response and the results agreed well with the certified values. Satisfactory analytical results were also obtained in real sample analysis of TCM Curcuma wenyujin Y.H. Chen et C. Ling. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 169
页数:6
相关论文
共 50 条
  • [1] ICP-OES Multi-element Analysis of Wheat Grown in Southeastern Turkey
    Duz, M. Zahir
    Duzgun, Mehmet
    Cam, Belgizar
    Celik, K. Serdar
    Kilinc, Ersin
    ATOMIC SPECTROSCOPY, 2017, 38 (01) : 1 - 6
  • [2] Multi-element Analysis of Vitreous Humor Samples by ICP-MS and ICP-OES
    Vazquez, M.
    Ibarra, I.
    Sibon, A.
    Perez-Carceles, M. D.
    ATOMIC SPECTROSCOPY, 2017, 38 (05) : 124 - 132
  • [3] Determination of antimony in river water by hydride generation ICP-OES
    Hou, HB
    Narasaki, H
    ATOMIC SPECTROSCOPY, 1998, 19 (01) : 23 - 25
  • [4] Simplified multi-element analysis of ground and instant coffees by ICP-OES and FAAS
    Szymczycha-Madeja, Anna
    Welna, Maja
    Pohl, Pawel
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (09): : 1488 - 1500
  • [5] System optimization for determination of cobalt in biological samples by ICP-OES using photochemical vapor generation
    de Jesus, Honerio Coutinho
    Grinberg, Patricia
    Sturgeon, Ralph E.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (08) : 1590 - 1604
  • [6] Vapor Generation for Metal Determination in Steels Using ICP-OES
    Pena-Vazquez, E.
    Villanueva-Alonso, J.
    Bermejo-Barrera, P.
    ATOMIC SPECTROSCOPY, 2008, 29 (05) : 180 - 185
  • [7] Chemometric intraregional discrimination of Chinese liquors based on multi-element determination by ICP-MS and ICP-OES
    Xiong, Qing
    Lin, Yanmei
    Wu, Wenlin
    Hu, Jing
    Li, Yizhou
    Xu, Kailai
    Wu, Xi
    Hou, Xiandeng
    APPLIED SPECTROSCOPY REVIEWS, 2021, 56 (02) : 115 - 127
  • [8] Geochemical Multi-element ICP-OES Analysis of Borehole Waters from SE Anatolia
    Duz, M. Zahir
    Sagirdag, Mehmet
    Celik, Kadir Serdar
    Hasan, Mahmood A.
    Kilinc, Ersin
    ATOMIC SPECTROSCOPY, 2016, 37 (02) : 43 - 49
  • [9] Characterization of Hatay honeys according to their multi-element analysis using ICP-OES combined with chemometrics
    Yucel, Yasin
    Sultanoglu, Pinar
    FOOD CHEMISTRY, 2013, 140 (1-2) : 231 - 237
  • [10] Multi-element analysis of wines by ICP-MS and ICP-OES and their classification according to geographical origin in Slovenia
    Selih, Vid S.
    Sala, Martin
    Drgan, Viktor
    FOOD CHEMISTRY, 2014, 153 : 414 - 423