TEST-RETEST RELIABILITY OF PRIMARY MOTOR CORTEX MAPPING: NEURONAVIGATED TRANSCRANIAL MAGNETIC BRAIN STIMULATION (NTMS) VERSUS FUNCTIONAL MRI (FMRI)

被引:0
|
作者
Weiss, Carolin [1 ]
Nettekoven, Charlotte [2 ]
Neuschmelting, Volker [1 ]
Eisenbeis, Andrea [1 ]
Rehme, Anne [2 ]
Grefkes, Christian [2 ]
Goldbrunner, Roland [1 ]
机构
[1] Univ Cologne, D-50931 Cologne, Germany
[2] Max Planck Inst Neurol Res, D-50931 Cologne, Germany
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:62 / 63
页数:2
相关论文
共 50 条
  • [1] TEST-RETEST RELIABILITY OF PRIMARY MOTOR CORTEX MAPPING: NEURONAVIGATED TRANSCRANIAL MAGNETIC BRAIN STIMULATION (NTMS) VERSUS FUNCTIONAL MRI (FMRI)
    Weiss, C.
    Neuschmelting, V.
    Eisenbeis, A.
    Nettekoven, C.
    Rehme, A.
    Grefkes, C.
    Goldbrunner, R.
    [J]. NEURO-ONCOLOGY, 2012, 14 : 34 - 35
  • [2] Test-retest Reliability of Navigated Transcranial Magnetic Stimulation of the Motor Cortex
    Cordella, Roberto
    Messina, Giuseppe
    Dimeco, Francesco
    [J]. OPERATIVE NEUROSURGERY, 2014, 10 (01) : 56 - 56
  • [4] Test-retest reliability of transcranial magnetic stimulation measures of motor cortex organization and excitability
    Malcolm, MP
    Triggs, WJ
    Khandekar, G
    Light, KE
    [J]. NEUROLOGY, 2004, 62 (07) : A281 - A281
  • [5] Mapping the hand, foot and face representations in the primary motor cortex - Retest reliability of neuronavigated TMS versus functional MRI
    Weiss, Carolin
    Nettekoven, Charlotte
    Rehme, Anne K.
    Neuschmelting, Volker
    Eisenbeis, Andrea
    Goldbrunner, Roland
    Grefkes, Christian
    [J]. NEUROIMAGE, 2013, 66 : 531 - 542
  • [6] Mapping of multiple muscles with transcranial magnetic stimulation: absolute and relative test-retest reliability
    Nazarova, Maria
    Novikov, Pavel
    Ivanina, Ekaterina
    Kozlova, Ksenia
    Dobrynina, Larisa
    Nikulin, Vadim V.
    [J]. HUMAN BRAIN MAPPING, 2021, 42 (08) : 2508 - 2528
  • [7] Test-retest reliability of transcranial magnetic stimulation EEG evoked potentials
    Kerwin, Lewis J.
    Keller, Corey J.
    Wu, Wei
    Narayan, Manjari
    Etkin, Amit
    [J]. BRAIN STIMULATION, 2018, 11 (03) : 536 - 544
  • [8] Test-Retest Reliability of Homeostatic Plasticity in the Human Primary Motor Cortex
    Thapa, Tribikram
    Schabrun, Siobhan M.
    [J]. NEURAL PLASTICITY, 2018, 2018
  • [9] RELIABILITY OF TRANSCRANIAL MAGNETIC STIMULATION FOR MAPPING THE HUMAN MOTOR CORTEX
    MORTIFEE, P
    STEWART, H
    SCHULZER, M
    EISEN, A
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 93 (02): : 131 - 137
  • [10] Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke
    Henriette, Busk
    Marianne, Nilsen
    Ronne, Pedersen Julie
    Glavin, Kristensen Malene
    Wesenberg, Kjaer Troels
    Thorgaard, Skou Soren
    Troels, Wienecke
    [J]. NEUROSCIENCE INSIGHTS, 2022, 17