A Comparison of Distributional Considerations with Statistical Analysis of Resting State fMRI at 3T and 7T

被引:7
|
作者
Yang, Xue [1 ]
Holmes, Martha J. [2 ]
Newton, Allen T. [3 ]
Morgan, Victoria L. [2 ,3 ]
Landman, Bennett A. [1 ,2 ,3 ,4 ]
机构
[1] Vanderbilt Univ, Elect Engn, 221 Kirkland Hall, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Radiol & Radiol Sci, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Inst Image Sci, Nashville, TN 37235 USA
[4] Johns Hopkins Univ, Biomed Engn, Baltimore, MD 21218 USA
来源
关键词
Statistical parametric mapping; ultra-high field; MRI; artifact; robust; inference; BAYESIAN-INFERENCE;
D O I
10.1117/12.911307
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Ultra-high field 7T magnetic resonance imaging (MRI) offers potentially unprecedented spatial resolution of functional activity within the human brain through increased signal and contrast to noise ratios over traditional 1.5T and 3T MRI scanners. However, the effects physiological and imaging artifacts are also greatly increased. Traditional statistical parametric mapping theories based on distributional properties representative of data acquired at lower fields may be inadequate for new 7T data. Herein, we investigate the model fitting residuals based on two 7T and one 3T protocols. We find that model residuals are substantively more non-Gaussian at 7T relative to 3T. Imaging slices that passed through regions with peak inhomogeneity problems (e. g., mid-brain acquisitions for the 7T hippocampus) exhibited visually higher degrees of distortion along with spatially correlated and extreme values of kurtosis (a measure of non-Gaussianity). The impacts of artifacts have been previously addressed for 3T data by estimating the covariance matrix of the regression errors. We further extend the robust estimation approach for autoregressive models and evaluate the qualitative impacts of this technique relative to traditional inference. Clear differences in statistical significance are shown between inferences based on classical versus robust assumptions, which suggest that inferences based on Gaussian assumptions are subject to practical (as well as theoretical) concerns regarding their power and validity. Hence, modern statistical approaches, such as the robust autoregressive model posed herein, are appropriate and suitable for inference with ultra-high field functional magnetic resonance imaging.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Individual Variability of Human Cortical Spontaneous Activity by 3T/7T fMRI
    Xing, Xiu-Xia
    Gao, Xiao
    Jiang, Chao
    NEUROSCIENCE, 2023, 528 : 117 - 128
  • [2] Statistical power comparisons at 3T and 7T with a GO / NOGO task
    Torrisi, Salvatore
    Chen, Gang
    Glen, Daniel
    Bandettini, Peter A.
    Baker, Chris I.
    Reynolds, Richard
    Liu, Jeffrey Yen-Ting
    Leshin, Joseph
    Balderston, Nicholas
    Grillon, Christian
    Ernst, Monique
    NEUROIMAGE, 2018, 175 : 100 - 110
  • [3] Visualization of wrist anatomy—a comparison between 7T and 3T MRI
    Simon Götestrand
    Anders Björkman
    Isabella M. Björkman-Burtscher
    Ingvar Kristiansson
    Elenya Aksyuk
    Pawel Szaro
    Karin Markenroth Bloch
    Mats Geijer
    European Radiology, 2022, 32 : 1362 - 1370
  • [4] Comparison of central vein detection in MS at 1.5T, 3T and 7T
    Fechner, A.
    Savatovsky, J.
    Sadik, J-C.
    Reich, D. S.
    Roux, P.
    Sati, P.
    MULTIPLE SCLEROSIS JOURNAL, 2017, 23 : 680 - 680
  • [5] Visualization of wrist anatomy-a comparison between 7T and 3T MRI
    Gotestrand, Simon
    Bjorkman, Anders
    Bjorkman-Burtscher, Isabella M.
    Kristiansson, Ingvar
    Aksyuk, Elenya
    Szaro, Pawel
    Bloch, Karin Markenroth
    Geijer, Mats
    EUROPEAN RADIOLOGY, 2022, 32 (02) : 1362 - 1370
  • [6] Editorial for "A Comparison of 3T and 7T MRI for the Clinical Evaluation of Uveal Melanoma"
    Bustin, Aurelien
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1516 - 1517
  • [7] Intracranial time-of-flight MR angiography at 7T with comparison to 3T
    von Morze, Cornelius
    Xu, Duan
    Purcell, Derk D.
    Hess, Christopher P.
    Mukherjee, Pratik
    Saloner, David
    Kelley, Douglas A. C.
    Vigneron, Daniel B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 900 - 904
  • [8] A comparison between 7T and 3T MR-imaging for Uveal Melanoma
    Tang, M. C. Y.
    Ferreira, T. A.
    Jaarsma-Coes, M. G.
    Marinkovic, M.
    Luyten, G. P. M.
    Beenakker, J. W. M.
    ACTA OPHTHALMOLOGICA, 2021, 99 : 26 - 27
  • [9] 7T MRI Synthesization from 3T Acquisitions
    Cui, Qiming
    Tosun, Duygu
    Mukherjee, Pratik
    Abbasi-Asl, Reza
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT VII, 2024, 15007 : 35 - 44
  • [10] Neuroimaging at 3T vs 7T Is It Really Worth It?
    Jones, Stephen E.
    Lee, Jonathan
    Law, Meng
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (01) : 1 - 12