Relaxation Time Estimation in MRI

被引:0
|
作者
Baselice, Fabio [1 ]
Ferraioli, Giampaolo [1 ]
Pascazio, Vito [1 ]
机构
[1] Univ Napoli Parthenope, Dipartimento Tecnol, Naples, Italy
关键词
Magnetic Resonance Imaging; Relaxation Time Estimation; Statistical Signal Processing;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, a novel estimator of proton density and relaxation times in Magnetic Resonance Imaging is presented. The evaluation of the signal model together with the statistical distribution of the noise have allowed the development of the Minimum Variance Unbiased (MVU) Estimator which, in case of complex decomposition of MRI data, corresponds to a Least Square (LS) one. With respect to amplitude base Maximum Likelihood Estimator, the proposed approach shows many advantages, including an higher accuracy due to the complex model and lower computational time due to the simple function. Results of real data are reported, showing the effectiveness of the method.
引用
收藏
页码:3975 / 3978
页数:4
相关论文
共 50 条
  • [1] FAST DENOISING TECHNIQUES FOR TRANSVERSE RELAXATION TIME ESTIMATION IN MRI
    Bjork, Marcus
    Stoica, Petre
    2013 PROCEEDINGS OF THE 21ST EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2013,
  • [2] Relaxation Times Estimation in MRI
    Baselice, Fabio
    Caivano, Rocchina
    Cammarota, Aldo
    Ferraioli, Giampaolo
    Pascazio, Vito
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [3] A Bayesian approach for relaxation times estimation in MRI
    Baselice, Fabio
    Ferraioli, Giampaolo
    Pascazio, Vito
    MAGNETIC RESONANCE IMAGING, 2016, 34 (03) : 312 - 325
  • [4] IMPROVED QUANTIFICATION OF MRI RELAXATION RATES USING BAYESIAN ESTIMATION
    Layton, Kelvin
    Morelande, Mark
    Johnston, Leigh A.
    Farrell, Peter M.
    Moran, Bill
    2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 481 - 484
  • [5] Estimation of the EEG power spectrum using MRI T2 relaxation time in traumatic brain injury
    Thatcher, RW
    Biver, C
    Gomez, JF
    North, D
    Curtin, R
    Walker, RA
    Salazar, A
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (09) : 1729 - 1745
  • [6] Estimation of spin-echo relaxation time
    Golub, F.
    Potter, L. C.
    Ash, J. N.
    Blank, A.
    Ahmad, R.
    JOURNAL OF MAGNETIC RESONANCE, 2013, 237 : 17 - 22
  • [7] Accuracy Confirmation of Relaxation Time Mapping in Synthetic MRI
    Seong-Ho Kim
    Jin-Seo Park
    Chan-Rok Park
    Ji-Sung Jang
    Soon-Yong Kwon
    Hyung-Jin Yang
    Journal of the Korean Physical Society, 2019, 74 : 892 - 900
  • [8] Accuracy Confirmation of Relaxation Time Mapping in Synthetic MRI
    Kim, Seong-Ho
    Park, Jin-Seo
    Park, Chan-Rok
    Jang, Ji-Sung
    Kwon, Soon-Yong
    Yang, Hyung-Jin
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (09) : 892 - 900
  • [9] Rapid MRI method for mapping the longitudinal relaxation time
    Hsu, JJ
    Glover, GH
    JOURNAL OF MAGNETIC RESONANCE, 2006, 181 (01) : 98 - 106
  • [10] Joint estimation of relaxation and diffusion tissue parameters for prostate cancer with relaxation-VERDICT MRI
    Marco Palombo
    Vanya Valindria
    Saurabh Singh
    Eleni Chiou
    Francesco Giganti
    Hayley Pye
    Hayley C. Whitaker
    David Atkinson
    Shonit Punwani
    Daniel C. Alexander
    Eleftheria Panagiotaki
    Scientific Reports, 13